U.S. flag

An official website of the United States government

Format

Send to:

Choose Destination

SRX982671: Bv6 amplicon freshwater: urban stormwater: Sample 093_FMRHC35
1 ILLUMINA (Illumina HiSeq 1000) run: 650,101 spots, 140.4M bases, 74.4Mb downloads

Design: "The hypervariable Bv6 region of the bacterial 16S rRNA gene (~60 bp) was amplified in two separate PCR reactions. The first amplified the Bv6 rRNA region with a set of primers that target all major bacterial groups using 25 cycles of amplification. DNA for sequencing was pooled from three independent PCR reactions, cleaned, and quality checked. Triplicate 33 mL reactions of the first PCR were pooled and the amplicon and negative control evaluated using a Caliper LabChip GX. Pooled amplicons were cleaned using a 96-well QIAquick PCR purification kit (Qiagen, Valencia CA) to remove primer dimer, salts and nucleotides. Following evaluation (as above), 5 mL of cleaned product were used as the template in the second PCR, where unique custom fusion primers (Illumina adaptor and 12 different inline barcodes for the forward primers plus 8 specific indices for reverse primers annealed to conserved regions flanking the Bv6 sequence) were added to the conserved region flanking the Bv6 sequence using an additional 5 cycles following the same condition as above. The PCR product and negative control for each sample were evaluated (as above) and each product was quantified using PicoGreen DNA assay (Life Technologies, Carlsbad CA). Products were pooled in equimolar fashion based on the PicoGreen quantity and the resulting pool was size selected to a range of 200-250bp using a 1.5% agarose Pipin prep cassette (SageScience, Beverly MA). The resulting product of size selection was cleaned with a Minelute column (Qiagen, Valencia CA) and quantified with a qPCR assay (Kapa Biosystems, Woburn MA). Samples were sequenced using v3 chemistry on an Illumina HiSeq 1000 with a custom 108-cycle paired-end read and six cycle index read recipe. Samples were part of a 96-sample multiplex run on the same lane with 50% of lane capacity dedicated to the 96 samples."
Submitted by: University of Wisconsin-Milwaukee
Study: Stormwater, river water, and lake water Targeted Locus (Loci)
show Abstracthide Abstract
Stormwater, river water, and Lake Michigan samples collected from the metropolitan Milwaukee, WI area
Sample: FMRHC35
SAMN03450056 • SRS897332 • All experiments • All runs
Library:
Name: HC35-1
Instrument: Illumina HiSeq 1000
Strategy: AMPLICON
Source: METAGENOMIC
Selection: PCR
Layout: PAIRED
Spot descriptor:
forward109  reverse

Runs: 1 run, 650,101 spots, 140.4M bases, 74.4Mb
Run# of Spots# of BasesSizePublished
SRR1957233650,101140.4M74.4Mb2015-08-27

ID:
1428196

Supplemental Content

Search details

See more...

Recent activity

Your browsing activity is empty.

Activity recording is turned off.

Turn recording back on

See more...