Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1984 1
1987 1
1989 2
1991 2
1992 1
1993 1
1994 2
1995 1
1997 3
1998 2
1999 2
2000 1
2001 3
2002 5
2003 6
2004 6
2005 4
2006 3
2007 5
2008 7
2009 11
2010 4
2011 4
2012 5
2013 9
2014 9
2015 9
2016 13
2017 4
2018 8
2019 9
2020 13
2021 5
2022 9
2023 8
2024 9

Text availability

Article attribute

Article type

Publication date

Search Results

169 results

Results by year

Filters applied: . Clear all
Page 1
Multivariate analysis of the effect of staining beverages on the optical properties of two provisional restorative materials.
Sánchez-Tito M, Blanco-Victorio D, Chauca-Carhuajulca J. Sánchez-Tito M, et al. J Clin Exp Dent. 2023 Jul 1;15(7):e535-e541. doi: 10.4317/jced.60431. eCollection 2023 Jul. J Clin Exp Dent. 2023. PMID: 37519320 Free PMC article.
MATERIAL AND METHODS: Sixty discs (8 mm x 2 mm) were manufactured for Duralay and Protemp 4. The discs were randomly divided according to the beverages: tea, coffee, wine, Coca-Cola and "Chicha morada" (n=12). ...The greatest change in deltaTP for Duralay were generated by …
MATERIAL AND METHODS: Sixty discs (8 mm x 2 mm) were manufactured for Duralay and Protemp 4. The discs were randomly divided accordin …
Physical and structural characterization of bis-acryl composite resin.
Rodríguez-Guardado WE, Rivera-Muñoz EM, Serrano-Bello J, Alvarez-Perez MA, Domínguez-Pérez RA, Salmerón-Valdés EN, Vázquez Vázquez FC, Chanes-Cuevas OA, Millán-Malo B, Peza-Ledesma CL, Correa-Prado R. Rodríguez-Guardado WE, et al. Sci Rep. 2024 Apr 6;14(1):8075. doi: 10.1038/s41598-024-58649-9. Sci Rep. 2024. PMID: 38580685 Free PMC article.
The objective of this study was to determine if the chemical and structural characteristics could cause to increase the fracture resistance, we used four bis-acryl resins Luxatemp, Protemp, Structur and Telio. Three-points bending by Flexural test were performed in ten bar …
The objective of this study was to determine if the chemical and structural characteristics could cause to increase the fracture resistance, …
A Comparative Evaluation of Fracture Toughness of Composite Resin vs Protemp 4 for Use in Strip Crowns: An In Vitro Study.
Vignesh KC, Kandaswamy E, Muthu MS. Vignesh KC, et al. Int J Clin Pediatr Dent. 2020 Jan-Feb;13(1):57-60. doi: 10.5005/jp-journals-10005-1711. Int J Clin Pediatr Dent. 2020. PMID: 32581481 Free PMC article.
The data also showed that the fracture toughness of Protemp 4 was comparable with pedo shade packable composite resin. ...A Comparative Evaluation of Fracture Toughness of Composite Resin vs Protemp 4 for Use in Strip Crowns: An In Vitro Study. Int J Clin Pediatr De …
The data also showed that the fracture toughness of Protemp 4 was comparable with pedo shade packable composite resin. ...A Comparati …
Laboratory Study of Color Stability of Different Types of Materials for Temporary Constructions.
Doshev AV, Slavchev D, Doshev V. Doshev AV, et al. Folia Med (Plovdiv). 2020 Sep 30;62(3):553-562. doi: 10.3897/folmed.62.e49568. Folia Med (Plovdiv). 2020. PMID: 33009746
MATERIALS AND METHODS: Two materials for temporary restoration were tested - Protemp II and Protemp IV, of which a total of 100 test specimens, were fabricated. ...CONCLUSION: Based on this study, the strong colouring effect of coffee and red wine on these restorati …
MATERIALS AND METHODS: Two materials for temporary restoration were tested - Protemp II and Protemp IV, of which a total of 10 …
Monotonic flexure and fatigue strength of composites for provisional and definitive restorations.
Scherrer SS, Wiskott AH, Coto-Hunziker V, Belser UC. Scherrer SS, et al. J Prosthet Dent. 2003 Jun;89(6):579-88. doi: 10.1016/s0022-3913(03)00174-4. J Prosthet Dent. 2003. PMID: 12815352
MATERIAL AND METHODS: Artglass, Colombus, and Targis (composites) and Jet, Protemp II, Protemp Garant, and Provipont DC (provisional restorations) were subjected to mechanical tests. ...RESULTS: The mean fatigue resistances (S(50)) in MPa +/- SD were: Targis, 62.1 + …
MATERIAL AND METHODS: Artglass, Colombus, and Targis (composites) and Jet, Protemp II, Protemp Garant, and Provipont DC (provi …
Pulpal response to a bis-acryl-plastic (Protemp) temporary crown and bridge material.
Fleisch L, Cleaton-Jones P, Forbes M, van Wyk J, Fat C. Fleisch L, et al. J Oral Pathol. 1984 Dec;13(6):622-31. doi: 10.1111/j.1600-0714.1984.tb01464.x. J Oral Pathol. 1984. PMID: 6440957
The pulpal response to Protemp (ESPE Gmbh) was compared to zinc oxide-eugenol, Super Syntrex (de Trey) and Protemp plus zinc oxide-eugenol liner in 144 vervet monkey (Cercopithecus pygerythus) incisor teeth, according to ADA Specification No. 41. ...
The pulpal response to Protemp (ESPE Gmbh) was compared to zinc oxide-eugenol, Super Syntrex (de Trey) and Protemp plus zinc o …
Effects of various beverages on characteristics of provisional restoration materials.
Wayakanon P, Narakaew T, Wayakanon K. Wayakanon P, et al. Clin Exp Dent Res. 2024 Apr;10(2):e842. doi: 10.1002/cre2.842. Clin Exp Dent Res. 2024. PMID: 38597122 Free PMC article.
Integrity showed the biggest changes, followed by acrylic resin and PMMA block, whereas Protemp had the smallest changes. The hardness of all the materials significantly decreased after immersion in any of the beverages for 14 days. ...
Integrity showed the biggest changes, followed by acrylic resin and PMMA block, whereas Protemp had the smallest changes. The hardnes …
Elution from direct composites for provisional restorations.
Turkalj M, De Nys S, Godderis L, Vanoirbeek J, Van Meerbeek B, Van Landuyt KL. Turkalj M, et al. J Prosthodont Res. 2024 Apr 12. doi: 10.2186/jpr.JPR_D_23_00305. Online ahead of print. J Prosthodont Res. 2024. PMID: 38616126 Free article.
Purpose To assess elution from direct composite materials for provisional restorations and compare them with elution from direct restorative composites for permanent restorations.Methods Two dual-cure (Integrity Multi-Cure and Tempsmart DC) and two self-curing composites (Prot
Purpose To assess elution from direct composite materials for provisional restorations and compare them with elution from direct restorative …
Discoloration of provisional restorations after oral rinses.
Turgut S, Bagis B, Ayaz EA, Ulusoy KU, Altintas SH, Korkmaz FM, Bagis N. Turgut S, et al. Int J Med Sci. 2013 Aug 30;10(11):1503-9. doi: 10.7150/ijms.6647. eCollection 2013. Int J Med Sci. 2013. PMID: 24046524 Free PMC article.
After immersion in chlorhexidine, the color change values of Protemp II and Fill-in showed significant differences (p=0.018). Protemp II also showed less discoloration than the other bis-acryl composites, and this color change was statistically significant (p <0. …
After immersion in chlorhexidine, the color change values of Protemp II and Fill-in showed significant differences (p=0.018). Prot
In vitro comparison of the surface roughness of polymethyl methacrylate and bis-acrylic resins for interim restorations before and after polishing.
Gantz L, Fauxpoint G, Arntz Y, Pelletier H, Etienne O. Gantz L, et al. J Prosthet Dent. 2021 May;125(5):833.e1-833.e10. doi: 10.1016/j.prosdent.2021.02.009. Epub 2021 Mar 6. J Prosthet Dent. 2021. PMID: 33685655
MATERIAL AND METHODS: Specimens made of different bis-acrylic resins (Protemp 4, Luxatemp Star, Systemp, Telio, Structur Premium, Structur 3) or of polymethyl methacrylate (Unifast Trad, Unifast 3) were polished using a 2-step polishing system (Diatech). ...Pairwise multip …
MATERIAL AND METHODS: Specimens made of different bis-acrylic resins (Protemp 4, Luxatemp Star, Systemp, Telio, Structur Premium, Str …
169 results