Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1985 1
1986 1
1987 1
1989 2
1990 1
1992 1
1994 1
1996 1
2000 2
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

11 results

Results by year

Filters applied: . Clear all
Page 1
Gutta-percha softening: "Hemo-De" as a xylene substitute.
Metzger Z, Marian-Kfir V, Tamse A. Metzger Z, et al. J Endod. 2000 Jul;26(7):385-8. doi: 10.1097/00004770-200007000-00001. J Endod. 2000. PMID: 11199760
The putative hazardous nature of chloroform and xylene implies that safer substitutes should be considered. Standard cylindrical gutta-percha samples were immersed in Hemo-De, a xylene substitute, for 60 s at 37 degrees C. Weight loss of a sample, after drying, was …
The putative hazardous nature of chloroform and xylene implies that safer substitutes should be considered. Standard cylindrical gutta-perch …
Hemo-De as substitute for ethyl acetate in formalin-ethyl acetate concentration technique.
Neimeister R, Logan AL, Gerber B, Egleton JH, Kleger B. Neimeister R, et al. J Clin Microbiol. 1987 Feb;25(2):425-6. doi: 10.1128/jcm.25.2.425-426.1987. J Clin Microbiol. 1987. PMID: 3818930 Free PMC article.
In comparative studies, Hemo-De (PMP Medical Industries, Inc., Irving, Tex.) was found to be a suitable replacement for ethyl acetate in the Formalin-ethyl acetate concentration technique. With essentially equivalent recovery rates for both procedures, the Formalin- …
In comparative studies, Hemo-De (PMP Medical Industries, Inc., Irving, Tex.) was found to be a suitable replacement for ethyl …
Hemo-De and xylene in Ehrlich indole test.
Egleton JH, Reynolds SM, Neimeister R. Egleton JH, et al. J Clin Microbiol. 1990 Feb;28(2):402. doi: 10.1128/jcm.28.2.402-.1990. J Clin Microbiol. 1990. PMID: 2179266 Free PMC article. No abstract available.
Use of terpene-based solvents (Hemo-De, Histoclear, and Shandon and BDH xylene substitutes) in place of xylene in the Ehrlich indole test.
Gubash SM, Bennett EE. Gubash SM, et al. J Clin Microbiol. 1989 Sep;27(9):2136-7. doi: 10.1128/jcm.27.9.2136-2137.1989. J Clin Microbiol. 1989. PMID: 2778079 Free PMC article.
Although less effective than xylene and Kovacs reagent as indole extractants, Hemo-De and Shandon xylene substitute can be used in the Ehrlich indole test if a less toxic solvent is desirable. ...
Although less effective than xylene and Kovacs reagent as indole extractants, Hemo-De and Shandon xylene substitute can be use …
Use of Hemo-De to eliminate toxic agents used for concentration and trichrome staining of intestinal parasites.
Aldeen WE, Hale D. Aldeen WE, et al. J Clin Microbiol. 1992 Jul;30(7):1893-5. doi: 10.1128/jcm.30.7.1893-1895.1992. J Clin Microbiol. 1992. PMID: 1378456 Free PMC article.
In a blind comparison, 465 randomly collected clinical fecal specimens were examined. Hemo-De was found to be an excellent replacement for ethyl acetate in the concentration procedure and for carbol-xylene and xylene in the trichrome staining procedure. Elimination …
In a blind comparison, 465 randomly collected clinical fecal specimens were examined. Hemo-De was found to be an excellent rep …
Biodegradable, effective substitute for xylene in the Ehrlich indole procedure.
Miller JM, Miller MD, Driscoll PE, Miller P. Miller JM, et al. J Clin Microbiol. 1994 Aug;32(8):2028-30. doi: 10.1128/jcm.32.8.2028-2030.1994. J Clin Microbiol. 1994. PMID: 7989564 Free PMC article.
Three extracting reagents were compared for effectiveness in the Ehrlich indole procedure: xylene (the recommended reagent), Hemo-De (a terpene-based product containing d-limonene), and Micro-Clear (an isoparaffinic hydrocarbon). ...Micro-Clear allowed detection in …
Three extracting reagents were compared for effectiveness in the Ehrlich indole procedure: xylene (the recommended reagent), Hemo- …
Modified trichrome staining technique with a xylene substitute.
Neimeister R, Logan AL, Egleton JH. Neimeister R, et al. J Clin Microbiol. 1985 Aug;22(2):306-7. doi: 10.1128/jcm.22.2.306-307.1985. J Clin Microbiol. 1985. PMID: 4031042 Free PMC article.
Hemo-De was evaluated and found to be a suitable replacement for xylene in the Wheatly trichrome staining of polyvinyl alcohol-fixed fecal smears used in the microscopic identification of intestinal protozoans....
Hemo-De was evaluated and found to be a suitable replacement for xylene in the Wheatly trichrome staining of polyvinyl alcohol
Performance of para-Pak Ultra ECOFIX compared with Para-Pak Ultra formalin/mercuric chloride-based polyvinyl alcohol for concentration and permanent stained smears of stool parasites.
Fedorko DP, Williams EC, Nelson NA, Mazyck TD, Hanson KL, Cartwright CP. Fedorko DP, et al. Diagn Microbiol Infect Dis. 2000 May;37(1):37-9. doi: 10.1016/s0732-8893(00)00121-8. Diagn Microbiol Infect Dis. 2000. PMID: 10794938
A total of 261 specimens in 92 sets (77 with 3 specimens, 15 with 2 specimens) were collected in ECOFIX, formalin, and low viscosity polyvinyl alcohol (LV-PVA). Concentrations were performed from ECOFIX using Hemo-De and saline and from formalin using ethyl acetate …
A total of 261 specimens in 92 sets (77 with 3 specimens, 15 with 2 specimens) were collected in ECOFIX, formalin, and low viscosity polyvin …
Evaluation of a xylene substitute in Ehrlich indole test.
Egleton JH, Fraser GP, Gerber B, Logan AL, Rinehardt CJ, Reynolds SM, Neimeister R. Egleton JH, et al. J Clin Microbiol. 1986 Nov;24(5):859. doi: 10.1128/jcm.24.5.859-.1986. J Clin Microbiol. 1986. PMID: 3533988 Free PMC article.
Hemo-De (PMP Medical Industries, Inc., Irving, Tex.) was evaluated and found to be a suitable substitute for xylene in the Ehrlich modification of the indole test....
Hemo-De (PMP Medical Industries, Inc., Irving, Tex.) was evaluated and found to be a suitable substitute for xylene in the Ehr
Use of a single slide trichrome-stained concentrate for the detection of intestinal parasites. Stained concentration procedure for ova and parasites.
Hale DC, Carroll K, Kucera JR, Aldeen WE. Hale DC, et al. Am J Clin Pathol. 1996 Aug;106(2):175-9. doi: 10.1093/ajcp/106.2.175. Am J Clin Pathol. 1996. PMID: 8712169
Of the 1,000 specimens evaluated, a total of 261 parasites were detected using the single slide, modified trichrome-stained concentrate compared to 249 from the formalin/Hemo-De wet mount and 226 from the unconcentrated trichrome stain. The detection rate of the sin …
Of the 1,000 specimens evaluated, a total of 261 parasites were detected using the single slide, modified trichrome-stained concentrate comp …
11 results