Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1991 1
1994 1
1995 1
1998 1
2006 1
2007 2
2008 4
2009 2
2011 1
2012 3
2013 2
2014 3
2015 4
2016 2
2017 1
2018 6
2019 6
2020 1
2021 4
2022 5
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

43 results

Results by year

Filters applied: . Clear all
Page 1
Thyroid nodule core needle biopsy - current approach.
Karatay E, Javadov M, Kaya H. Karatay E, et al. Endokrynol Pol. 2023;74(6). doi: 10.5603/ep.97053. Epub 2023 Nov 23. Endokrynol Pol. 2023. PMID: 37994586
Fine needle aspiration biopsy (FNAB) guided by ultrasonography is routinely used to identify thyroid nodules prior to surgery. ...Thyroid nodules can now be diagnosed with spring-activated single- or double-action needles following the introduct …
Fine needle aspiration biopsy (FNAB) guided by ultrasonography is routinely used to identify thyroid nodules prior to s …
Comparison of Ultrasound-Guided Fine-Needle Cytology Quality in Thyroid Nodules with 22-, 23-, and 25-Gauge Needles.
Dong Y, Gao L, Sui Y, Mao M, Zhan W, Zhou J. Dong Y, et al. Anal Cell Pathol (Amst). 2021 Jun 7;2021:5544921. doi: 10.1155/2021/5544921. eCollection 2021. Anal Cell Pathol (Amst). 2021. PMID: 34211823 Free PMC article.
OBJECTIVE: To compare the cytology quality of ultrasound-guided fine-needle biopsy in thyroid nodules with 22-, 23-, and 25-gauge (G) needles prospectively. ...However, the differences were not statistically significant in nondiagnostic rate using diff …
OBJECTIVE: To compare the cytology quality of ultrasound-guided fine-needle biopsy in thyroid nodules with 22-, 23-, an …
Ultrasound Guided Thyroid Biopsy.
Smith T, Kaufman CS. Smith T, et al. Tech Vasc Interv Radiol. 2021 Sep;24(3):100768. doi: 10.1016/j.tvir.2021.100768. Epub 2021 Sep 27. Tech Vasc Interv Radiol. 2021. PMID: 34861967
Fine needle aspiration (FNA) is an excellent low-risk procedure used to evaluate suspicious thyroid nodules and identify thyroid malignancy. It is performed with a 22-27-gauge needle under ultrasound guidance. Core needle biopsy (CNB) is usually …
Fine needle aspiration (FNA) is an excellent low-risk procedure used to evaluate suspicious thyroid nodules and identify th
Fine-needle aspiration cytology of thyroid nodule: does the needle matter?
Cappelli C, Pirola I, Gandossi E, De Martino E, Agosti B, Castellano M. Cappelli C, et al. South Med J. 2009 May;102(5):498-501. doi: 10.1097/SMJ.0b013e31819c7343. South Med J. 2009. PMID: 19373168
OBJECTIVES: Ultrasound-guided fine needle aspiration cytology (US-FNAC) represents the most effective test available to distinguish between benign and malignant thyroid nodules. ...METHODS: 1468 nodules were submitted to US-FNAC by two different 25-gauge n
OBJECTIVES: Ultrasound-guided fine needle aspiration cytology (US-FNAC) represents the most effective test available to distin …
Optimal needle size for thyroid fine needle aspiration cytology.
Tanaka A, Hirokawa M, Higuchi M, Kanematsu R, Suzuki A, Kuma S, Hayashi T, Kudo T, Miyauchi A. Tanaka A, et al. Endocr J. 2019 Feb 28;66(2):143-147. doi: 10.1507/endocrj.EJ18-0422. Epub 2018 Nov 21. Endocr J. 2019. PMID: 30464152 Free article.
Concerning the needle size for thyroid fine needle aspiration cytology (FNAC), 25-27-gauge needles are generally used in Western countries. However, in Japan, the use of larger needles (21-22-gauge needles) is common. The aim of ou …
Concerning the needle size for thyroid fine needle aspiration cytology (FNAC), 25-27-gauge needles are ge …
Comparison of cytological adequacy and pain scale score in ultrasound-guided fine-needle aspiration of solid thyroid nodules for liquid-based cytology with with 23- and 25-gauge needles: a single-center prospective study.
Lee YJ, Kim DW, Shin GW, Heo YJ, Baek JW, Choo HJ, Cho YJ, Jung SJ, Baek HJ. Lee YJ, et al. Sci Rep. 2019 May 7;9(1):7027. doi: 10.1038/s41598-019-43615-7. Sci Rep. 2019. PMID: 31065031 Free PMC article.
In ultrasound (US)-guided fine-needle aspiration (FNA) of solid thyroid nodules (STN) using liquid-based cytology (LBC), the most appropriate needle size for LBC remains unclear. ...A cytopathologist retrospectively analyzed the cytological adeq …
In ultrasound (US)-guided fine-needle aspiration (FNA) of solid thyroid nodules (STN) using liquid-based cytology (LBC) …
Association between Tsukuba elasticity scores 4 and 5 on elastography and Bethesda undetermined cytology on US-guided FNA with 27-G needle, verified by histopathology: a cut-off point of 20 mm of diameter designated for thyroid nodules.
Sengul D, Sengul I. Sengul D, et al. J BUON. 2019 Jan-Feb;24(1):382-390. J BUON. 2019. PMID: 30941995 Free article.
The cut-off point was 20 mm of a thyroid nodule. METHODS: A retrospective analysis from April 2012 to April 2016 was conducted by examining the records of 547 consecutive eligible patients with 655 thyroid nodules, the undetermined cytology of which su …
The cut-off point was 20 mm of a thyroid nodule. METHODS: A retrospective analysis from April 2012 to April 2016 was conducted …
Comparison Study of the Adequacy and Pain Scale of Ultrasound-Guided Fine-Needle Aspiration of Solid Thyroid Nodules with a 21- or 23-Gauge Needle for Liquid-Based Cytology: a Single-Center Study.
Jung SJ, Kim DW, Baek HJ. Jung SJ, et al. Endocr Pathol. 2018 Mar;29(1):30-34. doi: 10.1007/s12022-017-9508-1. Endocr Pathol. 2018. PMID: 29275502 Clinical Trial.
No published study has compared the cytological adequacy between different caliber needles in liquid-based cytology (LBC) after fine-needle aspiration (FNA) of thyroid nodules. ...Of the 88 STNs, 10 (11.4%) showed inadequate cytology: 6 f …
No published study has compared the cytological adequacy between different caliber needles in liquid-based cytology (LB …
Risk stratification of the thyroid nodule with Bethesda indeterminate cytology, category III, IV, V on the one surgeon-performed US-guided fine-needle aspiration with 27-gauge needle, verified by histopathology of thyroidectomy: the additional value of one surgeon-performed elastography.
Sengul D, Sengul I, Van Slycke S. Sengul D, et al. Acta Chir Belg. 2019 Feb;119(1):38-46. doi: 10.1080/00015458.2018.1551769. Epub 2019 Jan 4. Acta Chir Belg. 2019. PMID: 30606092
METHODS: The data was obtained by ultrasonography (US)-guided fine-needle aspiration (US-g-FNA) via 27-gauge needle, with the verification of indicated thyroidectomies in a retrospective analysis, from April 2010 to April 2014, by enrolling the documents of 2 …
METHODS: The data was obtained by ultrasonography (US)-guided fine-needle aspiration (US-g-FNA) via 27-gauge needle, wi …
Ultrasound-guided thyroid nodule fine-needle biopsies--comparison of sample adequacy with different sampling techniques, different needle sizes, and with/without onsite cytological analysis.
Cerit M, Yücel C, Göçün PU, Poyraz A, Cerit ET, Taneri F. Cerit M, et al. Endokrynol Pol. 2015;66(4):295-300. doi: 10.5603/EP.2015.0037. Endokrynol Pol. 2015. PMID: 26323465 Free article.
INTRODUCTION: The aim of this study was to compare the diagnostic adequacy of thyroid samples obtained by aspiration or capillary biopsy techniques, with 22 or 27 gauge needles, and with or without on-site cytological analysis (OCA). ...The capi …
INTRODUCTION: The aim of this study was to compare the diagnostic adequacy of thyroid samples obtained by aspiration or capill …
43 results