AJR Am J Roentgenol. 2011 Jan;196(1):15-22. doi: 10.2214/AJR.10.5290.

Response of arteriovenous malformations to gamma knife therapy evaluated with pulsed arterial spin-labeling MRI perfusion.

Author information

1
Department of Radiology, Wake Forest University Medical Center, Winston-Salem, NC, USA. jeffmpollock@gmail.com

Abstract

OBJECTIVE:

The goal of this study was to use pulsed arterial spin-labeling (PASL) MRI to evaluate the effect of gamma knife treatment on arteriovenous malformation (AVM) blood flow by measuring perfusion of the AVM nidus and nearby vascular territories.

CONCLUSION:

PASL can show and quantify the steal phenomena and the relative flow rates within the AVM nidus and may be used to follow AVM perfusion over time to assess treatment efficacy.

PMID:
21178042
DOI:
10.2214/AJR.10.5290
[Indexed for MEDLINE]