1.

Appropriate or inappropriate ICD shock; what is the post-shock rhythm?

van Gelder BM, Ter Burg B, Bracke FALE.

Neth Heart J. 2017 May 17. doi: 10.1007/s12471-017-0999-7. [Epub ahead of print] No abstract available.

PMID:
28516368
2.

Appropriate or inappropriate ICD shock; what is the post-shock rhythm?

van Gelder BM, Ter Burg B, Bracke FALE.

Neth Heart J. 2017 May 17. doi: 10.1007/s12471-017-1000-5. [Epub ahead of print] No abstract available.

PMID:
28516367
3.

Influenza infection and heart failure-vaccination may change heart failure prognosis?

Kadoglou NPE, Bracke F, Simmers T, Tsiodras S, Parissis J.

Heart Fail Rev. 2017 May;22(3):329-336. doi: 10.1007/s10741-017-9614-7. Review.

4.

To the Editor - Cardiac resynchronization therapy in coronary sinus atresia delivered using leadless endocardial pacing.

van Gelder BM, Bracke FA.

HeartRhythm Case Rep. 2017 Jan 21;3(3):194. doi: 10.1016/j.hrcr.2016.12.009. eCollection 2017 Mar. No abstract available.

5.

Adequate sensing of ventricular fibrillation?

Oomen AWGJ, van Gelder BM, Bracke FALE.

Neth Heart J. 2017 Apr 26. doi: 10.1007/s12471-017-0996-x. [Epub ahead of print] No abstract available.

PMID:
28447260
6.

Adequate sensing of ventricular fibrillation?

Oomen AWGJ, van Gelder BM, Bracke FALE.

Neth Heart J. 2017 Apr 26. doi: 10.1007/s12471-017-0995-y. [Epub ahead of print] No abstract available.

PMID:
28447259
7.

Timely detection of superior vena cava laceration with thoracoscopy during lead extraction.

Bracke FA, Verberkmoes N, van Gelder BM.

Heart Rhythm. 2016 Oct;13(10):2106-7. doi: 10.1016/j.hrthm.2016.06.027. Epub 2016 Jun 21. No abstract available.

PMID:
27353238
8.

Late asymptomatic atrial lead perforation, a fortuitous finding during lead extraction using thoracoscopic surveillance: a case report and review of the literature.

Van Gelder BM, Verberkmoes N, Nathoe R, Bracke FA.

Europace. 2016 Dec;18(12):1773-1778. doi: 10.1093/europace/euw054. Epub 2016 Jun 2. Review.

PMID:
27256428
9.

Haemodynamic evaluation of alternative left ventricular endocardial pacing sites in clinical non-responders to cardiac resynchronisation therapy.

van Gelder BM, Nathoe R, Bracke FA.

Neth Heart J. 2016 Jan;24(1):85-92. doi: 10.1007/s12471-015-0773-7.

10.

Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study.

Ritter P, Duray GZ, Steinwender C, Soejima K, Omar R, Mont L, Boersma LV, Knops RE, Chinitz L, Zhang S, Narasimhan C, Hummel J, Lloyd M, Simmers TA, Voigt A, Laager V, Stromberg K, Bonner MD, Sheldon TJ, Reynolds D; Micra Transcatheter Pacing Study Group.

Eur Heart J. 2015 Oct 1;36(37):2510-9. doi: 10.1093/eurheartj/ehv214. Epub 2015 Jun 4.

11.

Managing patients with advisory defibrillator leads: what can we learn from published data?

Bracke FA, van Gelder BM.

Neth Heart J. 2015 Apr;23(4):199-204. doi: 10.1007/s12471-015-0669-6.

12.

Letter to the Editor--Extraction of nonfunctional leads at the time of device upgrade: Still unproven benefit compared to abandoning leads.

Bracke F.

Heart Rhythm. 2015 Jul;12(7):e65. doi: 10.1016/j.hrthm.2015.03.064. Epub 2015 Mar 31. No abstract available.

PMID:
25839112
13.

Inappropriate shock because of triple counting in a patient with a subcutaneous implantable cardioverter defibrillator corrected by initiation of dual site left ventricular pacing.

van Gelder BM, Bracke FA, Simmers T.

Circ Arrhythm Electrophysiol. 2015 Feb;8(1):239-40. doi: 10.1161/CIRCEP.114.002116. No abstract available.

14.

Acute hemodynamic effects of single- and dual-site left ventricular pacing employing a dual cathodal coronary sinus lead.

van Gelder BM, Bracke FA.

Pacing Clin Electrophysiol. 2015 May;38(5):558-64. doi: 10.1111/pace.12606. Epub 2015 Mar 1.

PMID:
25640457
15.

Interaction between digoxin and dronedarone in the PALLAS trial.

Hohnloser SH, Halperin JL, Camm AJ, Gao P, Radzik D, Connolly SJ; PALLAS investigators.

Circ Arrhythm Electrophysiol. 2014 Dec;7(6):1019-25. doi: 10.1161/CIRCEP.114.002046. Epub 2014 Nov 6.

16.

Cross-manufacturer mismatch between a quadripolar IS-4 lead and a defibrillator IS-4 port.

Bracke FA, Nathoe R, van Gelder BM.

Heart Rhythm. 2014 Jul;11(7):1226-8. doi: 10.1016/j.hrthm.2014.03.054. Epub 2014 Mar 29. No abstract available.

PMID:
24691453
17.

Mid-term follow up of thromboembolic complications in left ventricular endocardial cardiac resynchronization therapy.

Rademakers LM, van Gelder BM, Scheffer MG, Bracke FA.

Heart Rhythm. 2014 Apr;11(4):609-13. doi: 10.1016/j.hrthm.2014.01.031. Epub 2014 Jan 29.

PMID:
24486432
18.

[The implantable cardiac defibrillator: indications and complications].

Simmers TA, Bracke FA.

Ned Tijdschr Geneeskd. 2013;157(47):A6328. Review. Dutch.

PMID:
24252404
19.

The Needle's Eye Snare as a primary tool for pacing lead extraction.

Bracke FA, Dekker L, van Gelder BM.

Europace. 2013 Jul;15(7):1007-12. doi: 10.1093/europace/eus426. Epub 2012 Dec 30.

PMID:
23277531
20.

Letter by van Gelder and Bracke regarding article, "Left ventricular versus simultaneous biventricular pacing in patients with heart failure and a QRS complex >120 milliseconds".

van Gelder BM, Bracke FA.

Circulation. 2012 Oct 9;126(15):e238; author reply e239. doi: 10.1161/CIRCULATIONAHA.112.096792. No abstract available.