Clin Endocrinol (Oxf). 1987 Feb;26(2):221-6.

Value of basal plasma cortisol assays in the assessment of pituitary-adrenal insufficiency.

Author information

1
Department of Medicine, University Hospital, Umeå, Sweden.

Abstract

A basal plasma cortisol value taken in a physically unstressed state in 68 patients with or without hypothalamic-pituitary-adrenocortical disease was compared with the maximal plasma cortisol concentration during an insulin tolerance test. There was a strong positive correlation between the values. Basal cortisol levels above 300 nmol/l (RIA method) almost excluded ACTH-cortisol insufficiency and those below 100 nmol/l strongly suggested dysfunction. A repeated basal cortisol estimation within a month was especially valuable in categorizing patients with levels between 100 and 200 nmol/l. We suggest that a basal cortisol measurement may be used as a first laboratory test in patients evaluated for possible hypothalamic-pituitary-adrenocortical insufficiency; in many patients, this approach obviates more sophisticated and expensive testing.