Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1984 1
1987 1
1993 1
1994 1
1999 2
2001 1
2002 2
2003 2
2004 1
2005 1
2006 1
2007 2
2008 1
2009 1
2011 2
2012 2
2013 2
2014 2
2015 1
2016 3
2017 2
2018 3
2019 4
2022 3
2023 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

39 results

Results by year

Filters applied: . Clear all
The following terms were ignored: %, %, %, %, %
The following terms were not found in PubMed: 22Filardi, 5BAuthor
Page 1
Perceptual impact of astigmatism induction in presbyopes.
Benedi-Garcia C, Velasco-Ocana M, Dorronsoro C, Pascual D, Hernandez M, Marin G, Marcos S. Benedi-Garcia C, et al. Vision Res. 2019 Dec;165:143-151. doi: 10.1016/j.visres.2019.10.008. Epub 2019 Nov 18. Vision Res. 2019. PMID: 31751899 Free article.
Measurements were performed using a custom-developed Adaptive Optics system, which allowed correction of high order aberrations and induction of astigmatism (0.5, 1, 1.5 and 2.0 D; axis: 180, 45 and 22.5). Upon induction of astigmatism, best focus shifted towards negative …
Measurements were performed using a custom-developed Adaptive Optics system, which allowed correction of high order aberrations and inductio …
Mass spectrometry imaging of biomarker lipids for phagocytosis and signalling during focal cerebral ischaemia.
Nielsen MM, Lambertsen KL, Clausen BH, Meyer M, Bhandari DR, Larsen ST, Poulsen SS, Spengler B, Janfelt C, Hansen HS. Nielsen MM, et al. Sci Rep. 2016 Dec 22;6:39571. doi: 10.1038/srep39571. Sci Rep. 2016. PMID: 28004822 Free PMC article.
Mass spectrometry imaging (desorption electrospray ionization and matrix assisted laser desorption ionization) was applied on brain sections from mice 2 h, 24 h, 5d, 7d, and 20d after permanent focal cerebral ischaemia. Within 24 h, N-acyl-phosphatidylethanolamines, …
Mass spectrometry imaging (desorption electrospray ionization and matrix assisted laser desorption ionization) was applied on brain sections …
A novel minimally invasive percutaneous treatment for Essex-Lopresti joint depression-type DIACFs by ligamentotaxis.
Chen Z, Fan C, Zhang J, Zhao C, Du X, Huang W, Ni W, Luo G. Chen Z, et al. BMC Surg. 2022 Dec 16;22(1):431. doi: 10.1186/s12893-022-01868-6. BMC Surg. 2022. PMID: 36527011 Free PMC article.
RESULTS: Thirty-nine patients with Essex-Lopresti joint depression type DIACFs were finally included. According to the Sanders classification, 22 were type II, 12 were type III and 5 were type IV. The preoperative waiting time and the hospital stay of Group A were 3.7 1.6 …
RESULTS: Thirty-nine patients with Essex-Lopresti joint depression type DIACFs were finally included. According to the Sanders classificatio …
Visual outcomes of a new nondiffractive extended depth-of-focus intraocular lens targeted for minimonovision: 3-month results of a prospective cohort study.
van Amelsfort T, Webers VSC, Bauer NJC, Clement LHH, van den Biggelaar FJHM, Nuijts RMMA. van Amelsfort T, et al. J Cataract Refract Surg. 2022 Feb 1;48(2):151-156. doi: 10.1097/j.jcrs.0000000000000825. J Cataract Refract Surg. 2022. PMID: 34653091
Outcome measures were the uncorrected distance visual acuity (UDVA), corrected distance visual acuity, uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), distance corrected intermediate visual acuity, distance corrected near visual acuity, refra …
Outcome measures were the uncorrected distance visual acuity (UDVA), corrected distance visual acuity, uncorrected intermediate visual acuit …
Predicted accommodative response from image quality in young eyes fitted with different dual-focus designs.
Faria-Ribeiro M, Amorim-de-Sousa A, González-Méijome JM. Faria-Ribeiro M, et al. Ophthalmic Physiol Opt. 2018 May;38(3):309-316. doi: 10.1111/opo.12443. Epub 2018 Jan 31. Ophthalmic Physiol Opt. 2018. PMID: 29383756
The mean standard deviation values obtained with the three adds were 0.28 0.02, 0.23 0.02 and 0.22 0.02, for the small, medium and larger IZ diameters, respectively. ...
The mean standard deviation values obtained with the three adds were 0.28 0.02, 0.23 0.02 and 0.22 0.02, for the small, medium and la …
Photopic visual input is necessary for emmetropization in mice.
Tkatchenko TV, Shen Y, Braun RD, Bawa G, Kumar P, Avrutsky I, Tkatchenko AV. Tkatchenko TV, et al. Exp Eye Res. 2013 Oct;115:87-95. doi: 10.1016/j.exer.2013.06.025. Epub 2013 Jul 6. Exp Eye Res. 2013. PMID: 23838522 Free PMC article.
Refractive Error and Anterior Chamber Depth as Risk Factors in Primary Angle Closure Disease: The Chinese American Eye Study.
Zhou S, Pardeshi AA, Burkemper B, Apolo G, Cho A, Jiang X, Torres M, McKean-Cowdin R, Varma R, Xu BY. Zhou S, et al. J Glaucoma. 2023 Apr 1;32(4):257-264. doi: 10.1097/IJG.0000000000002154. Epub 2023 Feb 22. J Glaucoma. 2023. PMID: 36847699
ACD (standardized regression coefficient = -0.54) was a 2.5-fold stronger predictor of PACD risk compared with RE (standardized regression coefficient = 0.22) when both variables were included in one multivariable model. The sensitivity and specificity of a 2.6 mm ACD cuto …
ACD (standardized regression coefficient = -0.54) was a 2.5-fold stronger predictor of PACD risk compared with RE (standardized regression c …
39 results