Format
Sort by
Items per page

Send to

Choose Destination

Search results

Items: 15

1.

Assessment of fasted and fed gastrointestinal contraction frequencies in healthy subjects using continuously tagged MRI.

de Jonge CS, Sprengers AMJ, van Rijn KL, Nederveen AJ, Stoker J.

Neurogastroenterol Motil. 2019 Dec 11:e13747. doi: 10.1111/nmo.13747. [Epub ahead of print]

PMID:
31828938
2.

Automated segmentation of trabecular and cortical bone from proton density weighted MRI of the knee.

Chen H, Sprengers AMJ, Kang Y, Verdonschot N.

Med Biol Eng Comput. 2019 May;57(5):1015-1027. doi: 10.1007/s11517-018-1936-7. Epub 2018 Dec 5.

3.

Accelerated 4D phase contrast MRI in skeletal muscle contraction.

Mazzoli V, Gottwald LM, Peper ES, Froeling M, Coolen BF, Verdonschot N, Sprengers AM, van Ooij P, Strijkers GJ, Nederveen AJ.

Magn Reson Med. 2018 Nov;80(5):1799-1811. doi: 10.1002/mrm.27158. Epub 2018 Mar 5.

PMID:
29508449
4.

Accelerated 4D self-gated MRI of tibiofemoral kinematics.

Mazzoli V, Schoormans J, Froeling M, Sprengers AM, Coolen BF, Verdonschot N, Strijkers GJ, Nederveen AJ.

NMR Biomed. 2017 Nov;30(11). doi: 10.1002/nbm.3791. Epub 2017 Sep 5.

PMID:
28873255
5.

Three-dimensional ultrasound strain imaging of skeletal muscles.

Gijsbertse K, Sprengers AM, Nillesen MM, Hansen HH, Lopata RG, Verdonschot N, de Korte CL.

Phys Med Biol. 2017 Jan 21;62(2):596-611. doi: 10.1088/1361-6560/aa5077. Epub 2016 Dec 29.

PMID:
28033112
6.

A novel diffusion-tensor MRI approach for skeletal muscle fascicle length measurements.

Oudeman J, Mazzoli V, Marra MA, Nicolay K, Maas M, Verdonschot N, Sprengers AM, Nederveen AJ, Strijkers GJ, Froeling M.

Physiol Rep. 2016 Dec;4(24). pii: e13012. doi: 10.14814/phy2.13012.

7.

Assessment of passive muscle elongation using Diffusion Tensor MRI: Correlation between fiber length and diffusion coefficients.

Mazzoli V, Oudeman J, Nicolay K, Maas M, Verdonschot N, Sprengers AM, Nederveen AJ, Froeling M, Strijkers GJ.

NMR Biomed. 2016 Dec;29(12):1813-1824. doi: 10.1002/nbm.3661. Epub 2016 Nov 8.

PMID:
27862471
8.

Noninvasive automated motion assessment of intestinal motility by continuously tagged MR imaging.

van der Paardt MP, Sprengers AM, Zijta FM, Lamerichs R, Nederveen AJ, Stoker J.

J Magn Reson Imaging. 2014 Jan;39(1):9-16. doi: 10.1002/jmri.24094. Epub 2013 Apr 1.

PMID:
23553805
9.

A scale space based algorithm for automated segmentation of single shot tagged MRI of shearing deformation.

Sprengers AM, Caan MW, Moerman KM, Nederveen AJ, Lamerichs RM, Stoker J.

MAGMA. 2013 Apr;26(2):229-38. doi: 10.1007/s10334-012-0332-9. Epub 2012 Aug 15.

PMID:
22892993
10.

A novel MRI compatible soft tissue indentor and fibre Bragg grating force sensor.

Moerman KM, Sprengers AM, Nederveen AJ, Simms CK.

Med Eng Phys. 2013 Apr;35(4):486-99. doi: 10.1016/j.medengphy.2012.06.014. Epub 2012 Jul 20.

PMID:
22819569
11.

Validation of continuously tagged MRI for the measurement of dynamic 3D skeletal muscle tissue deformation.

Moerman KM, Sprengers AM, Simms CK, Lamerichs RM, Stoker J, Nederveen AJ.

Med Phys. 2012 Apr;39(4):1793-810. doi: 10.1118/1.3685579.

PMID:
22482602
12.

Use of continuously MR tagged imaging for automated motion assessment in the abdomen: a feasibility study.

Sprengers AM, van der Paardt MP, Zijta FM, Caan MW, Lamerichs RM, Nederveen AJ, Stoker J.

J Magn Reson Imaging. 2012 Aug;36(2):492-7. doi: 10.1002/jmri.23637. Epub 2012 Mar 12.

PMID:
22411355
13.

Validation of SPAMM tagged MRI based measurement of 3D soft tissue deformation.

Moerman KM, Sprengers AM, Simms CK, Lamerichs RM, Stoker J, Nederveen AJ.

Med Phys. 2011 Mar;38(3):1248-60.

PMID:
21520837
14.

Prediction of intracerebral haemorrhage after carotid endarterectomy by clinical criteria and intraoperative transcranial Doppler monitoring.

Jansen C, Sprengers AM, Moll FL, Vermeulen FE, Hamerlijnck RP, van Gijn J, Ackerstaff RG.

Eur J Vasc Surg. 1994 May;8(3):303-8.

PMID:
7912206
15.

Prediction of intracerebral haemorrhage after carotid endarterectomy by clinical criteria and intraoperative transcranial Doppler monitoring: results of 233 operations.

Jansen C, Sprengers AM, Moll FL, Vermeulen FE, Hamerlijnck RP, van Gijn J, Ackerstaff RG.

Eur J Vasc Surg. 1994 Mar;8(2):220-5.

PMID:
7910145

Supplemental Content

Loading ...
Support Center