Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 43

1.

Magnetic resonance imaging features of complications following hip replacement: A pictorial review.

Pilania K, Jankharia B.

Indian J Radiol Imaging. 2016 Apr-Jun;26(2):271-8. doi: 10.4103/0971-3026.184414.

2.

Difference in the acetabular cup orientation in standing and supine radiographs.

Khan M, Beckingsale T, Marsh M, Holland J.

J Orthop. 2016 Apr 5;13(3):168-70. doi: 10.1016/j.jor.2016.03.012. eCollection 2016 Sep.

PMID:
27408490
3.

CORR Insights(®): Does Degenerative Lumbar Spine Disease Influence Femoroacetabular Flexion in Patients Undergoing Total Hip Arthroplasty?

Dorr LD.

Clin Orthop Relat Res. 2016 Aug;474(8):1798-801. doi: 10.1007/s11999-016-4877-1. Epub 2016 May 10. No abstract available.

PMID:
27164960
4.

Retrospective cohort study of the performance of the Pinnacle metal on metal (MoM) total hip replacement: a single-centre investigation in combination with the findings of a national retrieval centre.

Langton DJ, Sidaginamale RP, Avery P, Waller S, Tank G, Lord J, Joyce T, Cooke N, Logishetty R, Nargol AV.

BMJ Open. 2016 Apr 29;6(4):e007847. doi: 10.1136/bmjopen-2015-007847.

5.

Metal-on-metal total hip arthroplasty: is there still a role in 2016?

Silverman EJ, Ashley B, Sheth NP.

Curr Rev Musculoskelet Med. 2016 Mar;9(1):93-6. doi: 10.1007/s12178-016-9323-1.

6.

The envelope of passive motion allowed by the capsular ligaments of the hip.

van Arkel RJ, Amis AA, Jeffers JR.

J Biomech. 2015 Nov 5;48(14):3803-9. doi: 10.1016/j.jbiomech.2015.09.002. Epub 2015 Sep 14.

7.

Metal-on-Metal Hip Arthroplasty: A Review of Adverse Reactions and Patient Management.

Drummond J, Tran P, Fary C.

J Funct Biomater. 2015 Jun 26;6(3):486-99. doi: 10.3390/jfb6030486. Review.

8.

Normalization of chromium and cobalt values after femoral head replacement.

Iacobellis C, Berizzi A, Pozzuoli A, Biz C.

Int J Surg Case Rep. 2015;10:146-50. doi: 10.1016/j.ijscr.2015.03.037. Epub 2015 Mar 27.

9.

The capsular ligaments provide more hip rotational restraint than the acetabular labrum and the ligamentum teres : an experimental study.

van Arkel RJ, Amis AA, Cobb JP, Jeffers JR.

Bone Joint J. 2015 Apr;97-B(4):484-91. doi: 10.1302/0301-620X.97B4.34638.

10.

Revision of Metal-on-metal Hip Prostheses Results in Marked Reduction of Blood Cobalt and Chromium Ion Concentrations.

Lainiala O, Reito A, Elo P, Pajamäki J, Puolakka T, Eskelinen A.

Clin Orthop Relat Res. 2015 Jul;473(7):2305-13. doi: 10.1007/s11999-015-4156-6. Epub 2015 Jan 27.

11.

Metal artifact reduction with MAVRIC SL at 3-T MRI in patients with hip arthroplasty.

Choi SJ, Koch KM, Hargreaves BA, Stevens KJ, Gold GE.

AJR Am J Roentgenol. 2015 Jan;204(1):140-7. doi: 10.2214/AJR.13.11785.

12.

Serum metal ion concentrations in paediatric patients following total knee arthroplasty using megaprostheses.

Friesenbichler J, Sadoghi P, Maurer-Ertl W, Szkandera J, Glehr M, Ogris K, Wolf M, Weger C, Leithner A.

Biomed Res Int. 2014;2014:817257. doi: 10.1155/2014/817257. Epub 2014 Sep 8.

13.

Do retrieval analysis and blood metal measurements contribute to our understanding of adverse local tissue reactions?

Campbell PA, Kung MS, Hsu AR, Jacobs JJ.

Clin Orthop Relat Res. 2014 Dec;472(12):3718-27. doi: 10.1007/s11999-014-3893-2. Review.

14.

The surgical options and clinical evidence for treatment of wear or corrosion occurring with THA or TKA.

Engh CA Jr, Ho H, Padgett DE.

Clin Orthop Relat Res. 2014 Dec;472(12):3674-86. doi: 10.1007/s11999-014-3652-4. Review.

15.

Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.

Marshall DA, Pykerman K, Werle J, Lorenzetti D, Wasylak T, Noseworthy T, Dick DA, O'Connor G, Sundaram A, Heintzbergen S, Frank C.

Clin Orthop Relat Res. 2014 Jul;472(7):2217-30. doi: 10.1007/s11999-014-3556-3. Epub 2014 Apr 4. Review.

16.

What causes unexplained pain in patients with metal-on metal hip devices? A retrieval, histologic, and imaging analysis.

Nawabi DH, Nassif NA, Do HT, Stoner K, Elpers M, Su EP, Wright T, Potter HG, Padgett DE.

Clin Orthop Relat Res. 2014 Feb;472(2):543-54. doi: 10.1007/s11999-013-3199-9.

17.

Bearing exchange in the management of pseudotumours.

Kemp MA, Mitra A, da Costa TM, Spencer RF.

Ann R Coll Surg Engl. 2013 May;95(4):266-70. doi: 10.1308/003588413X13511609958497.

18.

Taper junction failure in large-diameter metal-on-metal bearings.

Langton DJ, Sidaginamale R, Lord JK, Nargol AV, Joyce TJ.

Bone Joint Res. 2012 Apr 1;1(4):56-63. doi: 10.1302/2046-3758.14.2000047. Print 2012 Apr.

19.

Microseparation, fluid pressure and flow in failures of metal-on-metal hip resurfacing arthroplasties.

Wroblewski BM, Siney PD, Fleming PA.

Bone Joint Res. 2012 Mar 1;1(3):25-30. doi: 10.1302/2046-3758.13.2000040. Print 2012 Mar.

20.

Assessment of cup orientation in hip resurfacing: a comparison of TraumaCad and computed tomography.

Westacott DJ, McArthur J, King RJ, Foguet P.

J Orthop Surg Res. 2013 Apr 11;8:8. doi: 10.1186/1749-799X-8-8.

Items per page

Supplemental Content

Write to the Help Desk