Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 19


Mechanical Cardiopulmonary Resuscitation and Hospital Survival Among Adult Patients With Nontraumatic Out-of-Hospital Cardiac Arrest Attending the Emergency Department: A Prospective, Multicenter, Observational Study in Japan (SOS-KANTO [Survey of Survivors after Out-of-Hospital Cardiac Arrest in Kanto Area] 2012 Study).

Hayashida K, Tagami T, Fukuda T, Suzuki M, Yonemoto N, Kondo Y, Ogasawara T, Sakurai A, Tahara Y, Nagao K, Yaguchi A, Morimura N; SOS‐KANTO 2012 Study Group.

J Am Heart Assoc. 2017 Oct 31;6(11). pii: e007420. doi: 10.1161/JAHA.117.007420.


Prompt use of mechanical cardiopulmonary resuscitation in out-of-hospital cardiac arrest: the MECCA study report.

Anantharaman V, Ng BL, Ang SH, Lee CY, Leong SH, Ong ME, Chua SJ, Rabind AC, Anjali NB, Hao Y.

Singapore Med J. 2017 Jul;58(7):424-431. doi: 10.11622/smedj.2017071.


Clinical evaluation of the AutoPulse automated chest compression device for out-of-hospital cardiac arrest in the northern district of Shanghai, China.

Gao C, Chen Y, Peng H, Chen Y, Zhuang Y, Zhou S.

Arch Med Sci. 2016 Jun 1;12(3):563-70. doi: 10.5114/aoms.2016.59930. Epub 2016 May 18.


Mechanical versus manual chest compressions for cardiac arrest: a systematic review and meta-analysis.

Li H, Wang D, Yu Y, Zhao X, Jing X.

Scand J Trauma Resusc Emerg Med. 2016 Feb 1;24:10. doi: 10.1186/s13049-016-0202-y. Review.


Cardiopulmonary resuscitation using electrically driven devices: a review.

Prinzing A, Eichhorn S, Deutsch MA, Lange R, Krane M.

J Thorac Dis. 2015 Oct;7(10):E459-67. doi: 10.3978/j.issn.2072-1439.2015.10.40. Review.


How do paramedics manage the airway during out of hospital cardiac arrest?

Voss S, Rhys M, Coates D, Greenwood R, Nolan JP, Thomas M, Benger J.

Resuscitation. 2014 Dec;85(12):1662-6. doi: 10.1016/j.resuscitation.2014.09.008. Epub 2014 Sep 26.


Mechanical cardiopulmonary resuscitation for patients with cardiac arrest.

Jiang L, Zhang JS.

World J Emerg Med. 2011;2(3):165-8. doi: 10.5847/wjem.j.1920-8642.2011.03.001. Review.


Design of the PRINCESS trial: pre-hospital resuscitation intra-nasal cooling effectiveness survival study (PRINCESS).

Nordberg P, Taccone FS, Castren M, Truhlár A, Desruelles D, Forsberg S, Hollenberg J, Vincent JL, Svensoon L.

BMC Emerg Med. 2013 Nov 25;13:21. doi: 10.1186/1471-227X-13-21.


Year in review 2012: Critical Care--Out-of-hospital cardiac arrest and trauma.

Goldberg SA, Leatham A, Pepe PE.

Crit Care. 2013 Nov 22;17(6):248. doi: 10.1186/cc13128.


Obstacles delaying the prompt deployment of piston-type mechanical cardiopulmonary resuscitation devices during emergency department resuscitation: a video-recording and time-motion study.

Huang EP, Wang HC, Ko PC, Chang AM, Fu CM, Chen JW, Liao YC, Liu HC, Fang YD, Yang CW, Chiang WC, Ma MH, Chen SC.

Resuscitation. 2013 Sep;84(9):1208-13. doi: 10.1016/j.resuscitation.2013.03.028. Epub 2013 Apr 6.


Hyperinvasive approach to out-of hospital cardiac arrest using mechanical chest compression device, prehospital intraarrest cooling, extracorporeal life support and early invasive assessment compared to standard of care. A randomized parallel groups comparative study proposal. "Prague OHCA study".

Belohlavek J, Kucera K, Jarkovsky J, Franek O, Pokorna M, Danda J, Skripsky R, Kandrnal V, Balik M, Kunstyr J, Horak J, Smid O, Valasek J, Mrazek V, Schwarz Z, Linhart A.

J Transl Med. 2012 Aug 10;10:163. doi: 10.1186/1479-5876-10-163.


Improved neurologically intact survival with the use of an automated, load-distributing band chest compression device for cardiac arrest presenting to the emergency department.

Hock Ong ME, Fook-Chong S, Annathurai A, Ang SH, Tiah L, Yong KL, Koh ZX, Yap S, Sultana P.

Crit Care. 2012 Aug 3;16(4):R144. doi: 10.1186/cc11456.


An automated CPR device compared with standard chest compressions for out-of-hospital resuscitation.

Jennings PA, Harriss L, Bernard S, Bray J, Walker T, Spelman T, Smith K, Cameron P.

BMC Emerg Med. 2012 Jun 26;12:8. doi: 10.1186/1471-227X-12-8.


Mechanical CPR devices compared to manual CPR during out-of-hospital cardiac arrest and ambulance transport: a systematic review.

Ong ME, Mackey KE, Zhang ZC, Tanaka H, Ma MH, Swor R, Shin SD.

Scand J Trauma Resusc Emerg Med. 2012 Jun 18;20:39. doi: 10.1186/1757-7241-20-39. Review.


Anesthesia advanced circulatory life support.

Moitra VK, Gabrielli A, Maccioli GA, O'Connor MF.

Can J Anaesth. 2012 Jun;59(6):586-603. doi: 10.1007/s12630-012-9699-3. Epub 2012 Apr 21.


The impact of response time reliability on CPR incidence and resuscitation success: a benchmark study from the German Resuscitation Registry.

Neukamm J, Gräsner JT, Schewe JC, Breil M, Bahr J, Heister U, Wnent J, Bohn A, Heller G, Strickmann B, Fischer H, Kill C, Messelken M, Bein B, Lukas R, Meybohm P, Scholz J, Fischer M.

Crit Care. 2011;15(6):R282. doi: 10.1186/cc10566. Epub 2011 Nov 24.


Part 7: CPR techniques and devices: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

Cave DM, Gazmuri RJ, Otto CW, Nadkarni VM, Cheng A, Brooks SC, Daya M, Sutton RM, Branson R, Hazinski MF.

Circulation. 2010 Nov 2;122(18 Suppl 3):S720-8. doi: 10.1161/CIRCULATIONAHA.110.970970. Review.


Effect of the AutoPulse automated band chest compression device on hemodynamics in out-of-hospital cardiac arrest resuscitation.

Duchateau FX, Gueye P, Curac S, Tubach F, Broche C, Plaisance P, Payen D, Mantz J, Ricard-Hibon A.

Intensive Care Med. 2010 Jul;36(7):1256-60. doi: 10.1007/s00134-010-1784-x. Epub 2010 Mar 6.


Submersion, accidental hypothermia and cardiac arrest, mechanical chest compressions as a bridge to final treatment: a case report.

Friberg H, Rundgren M.

Scand J Trauma Resusc Emerg Med. 2009 Feb 20;17:7. doi: 10.1186/1757-7241-17-7.

Supplemental Content

Support Center