Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 92

1.

Undersensing of ventricular fibrillation by a biventricular implantable cardioverter-defibrillator: What is the cause and the troubleshooting?

Le KV, Okamura H, Nakajima K, Noda T, Kusano K.

J Arrhythm. 2019 Feb 22;35(2):276-278. doi: 10.1002/joa3.12170. eCollection 2019 Apr. No abstract available.

2.

Sinus rhythm R-wave amplitude as a predictor of ventricular fibrillation undersensing in patients with implantable cardioverter-defibrillator.

Ruetz LL, Koehler JL, Brown ML, Jackson TE, Belk P, Swerdlow CD.

Heart Rhythm. 2015 Dec;12(12):2411-8. doi: 10.1016/j.hrthm.2015.08.012. Epub 2015 Aug 10.

PMID:
26272520
3.

Survival after shock therapy in implantable cardioverter-defibrillator and cardiac resynchronization therapy-defibrillator recipients according to rhythm shocked. The ALTITUDE survival by rhythm study.

Powell BD, Saxon LA, Boehmer JP, Day JD, Gilliam FR 3rd, Heidenreich PA, Jones PW, Rousseau MJ, Hayes DL.

J Am Coll Cardiol. 2013 Oct 29;62(18):1674-1679. doi: 10.1016/j.jacc.2013.04.083. Epub 2013 Jun 27.

4.

Implantable cardioverter-defibrillator advances.

Lerman RD, Cannom DS.

Curr Opin Cardiol. 1996 Jan;11(1):16-22. Review.

PMID:
8664527
5.

Selective left ventricular sensing lead implantation to overcome undersensing of ventricular fibrillation during implantable cardioverter defibrillator implantation.

Steinberg C, Philippon F, O'Hara G, Molin F.

Can J Cardiol. 2013 Jun;29(6):751.e3-6. doi: 10.1016/j.cjca.2012.10.027. Epub 2013 Feb 6.

PMID:
23395280
6.

Results of the multicenter RENEWAL 3 AVT clinical study of cardiac resynchronization defibrillator therapy in patients with paroxysmal atrial fibrillation.

Saxon LA, Greenfield RA, Crandall BG, Nydegger CC, Orlov M, VAN Genderen R.

J Cardiovasc Electrophysiol. 2006 May;17(5):520-5.

PMID:
16684026
7.

Spurious redetection of sinus rhythm by an implantable cardioverter defibrillator during spontaneous ventricular fibrillation.

Otto L, Mann DE, Kelly PA, Reiter MJ.

Pacing Clin Electrophysiol. 1999 Oct;22(10):1550-2.

PMID:
10588160
8.

The effect of intermittent atrial tachyarrhythmia on heart failure or death in cardiac resynchronization therapy with defibrillator versus implantable cardioverter-defibrillator patients: a MADIT-CRT substudy (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy).

Ruwald AC, Pietrasik G, Goldenberg I, Kutyifa V, Daubert JP, Ruwald MH, Jons C, McNitt S, Wang P, Zareba W, Moss AJ.

J Am Coll Cardiol. 2014 Apr 1;63(12):1190-1197. doi: 10.1016/j.jacc.2013.10.074. Epub 2013 Dec 11.

9.

Appropriate implantable cardioverter-defibrillator interventions in cardiac resynchronization therapy-defibrillator (CRT-D) patients undergoing device replacement: time to downgrade from CRT-D to CRT-pacemaker? Insights from real-world clinical practice in the DECODE CRT-D analysis.

Narducci ML, Biffi M, Ammendola E, Vado A, Campana A, Potenza DR, Iori M, Zanon F, Zacà V, Zoni Berisso M, Bertini M, Lissoni F, Bandini A, Malacrida M, Crea F.

Europace. 2018 Sep 1;20(9):1475-1483. doi: 10.1093/europace/eux323.

PMID:
29186401
10.

The association between biventricular pacing and cardiac resynchronization therapy-defibrillator efficacy when compared with implantable cardioverter defibrillator on outcomes and reverse remodelling.

Ruwald AC, Kutyifa V, Ruwald MH, Solomon S, Daubert JP, Jons C, Brenyo A, McNitt S, Do D, Tanabe K, Al-Ahmad A, Wang P, Moss AJ, Zareba W.

Eur Heart J. 2015 Feb 14;36(7):440-8. doi: 10.1093/eurheartj/ehu294. Epub 2014 Aug 11.

PMID:
25112662
11.

Response of right ventricular size to treatment with cardiac resynchronization therapy and the risk of ventricular tachyarrhythmias in MADIT-CRT.

Doyle CL, Huang DT, Moss AJ, Solomon SD, Campbell P, McNitt S, Polonsky S, Barsheshet A, Aktas M, Tompkins C, Zareba W, Goldenberg I.

Heart Rhythm. 2013 Oct;10(10):1471-7. doi: 10.1016/j.hrthm.2013.07.029. Epub 2013 Jul 19.

PMID:
23872690
12.

[Long-term outcome of pharmacological and nonpharmacological treatment for ventricular arrhythmias].

Ohnishi S, Kasanuki H.

J Cardiol. 2000 Mar;35 Suppl 1:75-84. Review. Japanese.

PMID:
10834174
13.

R wave undersensing caused by an algorithm intended to enhance sensing specificity in an implantable cardioverter defibrillator.

Eberhardt F, Peters W, Bode F, Wiegand UK.

Pacing Clin Electrophysiol. 2003 Aug;26(8):1776-7.

PMID:
12877717
15.

A randomized study of cardiac resynchronization therapy defibrillator versus dual-chamber implantable cardioverter-defibrillator in ischemic cardiomyopathy with narrow QRS: the NARROW-CRT study.

Muto C, Solimene F, Gallo P, Nastasi M, La Rosa C, Calvanese R, Iengo R, Canciello M, Sangiuolo R, Diemberger I, Ciardiello C, Tuccillo B.

Circ Arrhythm Electrophysiol. 2013 Jun;6(3):538-45. doi: 10.1161/CIRCEP.113.000135. Epub 2013 Apr 16.

PMID:
23592833
16.

Delayed AICD therapy and cardiac arrest resulting from undersensing of ventricular fibrillation in a subject with hypertrophic cardiomyopathy-A case report.

Chin A, Healey JS, Ribas CS, Nair GM.

Indian Pacing Electrophysiol J. 2015 Jul 29;15(2):121-4. doi: 10.1016/j.ipej.2015.07.009. eCollection 2015 Mar-Apr.

17.

Undersensing by an ICD due to alternans of the ventricular electrogram.

Van Heuverswyn FE, Timmers L, Stroobandt RX, Barold SS.

Ann Noninvasive Electrocardiol. 2013 Jan;18(1):84-9. doi: 10.1111/j.1542-474X.2012.00521.x. Epub 2012 Aug 13.

PMID:
23347031
18.

Management of sudden cardiac death in cardiac sarcoidosis using the wearable cardioverter defibrillator.

Skowasch D, Ringquist S, Nickenig G, Andrié R.

PLoS One. 2018 Mar 22;13(3):e0194496. doi: 10.1371/journal.pone.0194496. eCollection 2018.

19.

2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.

Wilkoff BL, Fauchier L, Stiles MK, Morillo CA, Al-Khatib SM, Almendral J, Aguinaga L, Berger RD, Cuesta A, Daubert JP, Dubner S, Ellenbogen KA, Estes NA 3rd, Fenelon G, Garcia FC, Gasparini M, Haines DE, Healey JS, Hurtwitz JL, Keegan R, Kolb C, Kuck KH, Marinskis G, Martinelli M, McGuire M, Molina LG, Okumura K, Proclemer A, Russo AM, Singh JP, Swerdlow CD, Teo WS, Uribe W, Viskin S, Wang CC, Zhang S.

J Arrhythm. 2016 Feb;32(1):1-28. doi: 10.1016/j.joa.2015.12.001. Epub 2016 Feb 1. No abstract available. Erratum in: J Arrhythm. 2016 Oct;32(5):441-442.

20.

Supplemental Content

Support Center