Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 201

1.

Study protocol for a multicenter randomized controlled trial to compare the efficacy of end-ischemic dual hypothermic oxygenated machine perfusion with static cold storage in preventing non-anastomotic biliary strictures after transplantation of liver grafts donated after circulatory death: DHOPE-DCD trial.

van Rijn R, van den Berg AP, Erdmann JI, Heaton N, van Hoek B, de Jonge J, Leuvenink HGD, Mahesh SVK, Mertens S, Monbaliu D, Muiesan P, Perera MTPR, Polak WG, Rogiers X, Troisi RI, de Vries Y, Porte RJ.

BMC Gastroenterol. 2019 Mar 12;19(1):40. doi: 10.1186/s12876-019-0956-6.

2.

Hypothermic oxygenated machine perfusion reduces bile duct reperfusion injury after transplantation of donation after circulatory death livers.

van Rijn R, van Leeuwen OB, Matton APM, Burlage LC, Wiersema-Buist J, van den Heuvel MC, de Kleine RHJ, de Boer MT, Gouw ASH, Porte RJ.

Liver Transpl. 2018 May;24(5):655-664. doi: 10.1002/lt.25023. Epub 2018 Apr 6.

3.

Dual hypothermic oxygenated machine perfusion in liver transplants donated after circulatory death.

van Rijn R, Karimian N, Matton APM, Burlage LC, Westerkamp AC, van den Berg AP, de Kleine RHJ, de Boer MT, Lisman T, Porte RJ.

Br J Surg. 2017 Jun;104(7):907-917. doi: 10.1002/bjs.10515. Epub 2017 Apr 10.

4.

Hypothermic oxygenated perfusion (HOPE) protects from biliary injury in a rodent model of DCD liver transplantation.

Schlegel A, Graf R, Clavien PA, Dutkowski P.

J Hepatol. 2013 Nov;59(5):984-91. doi: 10.1016/j.jhep.2013.06.022. Epub 2013 Jun 29.

PMID:
23820408
5.

Normothermic machine perfusion reduces bile duct injury and improves biliary epithelial function in rat donor livers.

Op den Dries S, Karimian N, Westerkamp AC, Sutton ME, Kuipers M, Wiersema-Buist J, Ottens PJ, Kuipers J, Giepmans BN, Leuvenink HG, Lisman T, Porte RJ.

Liver Transpl. 2016 Jul;22(7):994-1005. doi: 10.1002/lt.24436.

6.

Hypothermic oxygenated machine perfusion prevents arteriolonecrosis of the peribiliary plexus in pig livers donated after circulatory death.

Op den Dries S, Sutton ME, Karimian N, de Boer MT, Wiersema-Buist J, Gouw AS, Leuvenink HG, Lisman T, Porte RJ.

PLoS One. 2014 Feb 14;9(2):e88521. doi: 10.1371/journal.pone.0088521. eCollection 2014.

7.

End-ischemic machine perfusion reduces bile duct injury in donation after circulatory death rat donor livers independent of the machine perfusion temperature.

Westerkamp AC, Mahboub P, Meyer SL, Hottenrott M, Ottens PJ, Wiersema-Buist J, Gouw AS, Lisman T, Leuvenink HG, Porte RJ.

Liver Transpl. 2015 Oct;21(10):1300-11. doi: 10.1002/lt.24200.

8.

First Comparison of Hypothermic Oxygenated PErfusion Versus Static Cold Storage of Human Donation After Cardiac Death Liver Transplants: An International-matched Case Analysis.

Dutkowski P, Polak WG, Muiesan P, Schlegel A, Verhoeven CJ, Scalera I, DeOliveira ML, Kron P, Clavien PA.

Ann Surg. 2015 Nov;262(5):764-70; discussion 770-1. doi: 10.1097/SLA.0000000000001473.

9.

Pretransplant sequential hypo- and normothermic machine perfusion of suboptimal livers donated after circulatory death using a hemoglobin-based oxygen carrier perfusion solution.

de Vries Y, Matton APM, Nijsten MWN, Werner MJM, van den Berg AP, de Boer MT, Buis CI, Fujiyoshi M, de Kleine RHJ, van Leeuwen OB, Meyer P, van den Heuvel MC, de Meijer VE, Porte RJ.

Am J Transplant. 2019 Apr;19(4):1202-1211. doi: 10.1111/ajt.15228. Epub 2019 Jan 23.

10.

An Oxygenated and Transportable Machine Perfusion System Fully Rescues Liver Grafts Exposed to Lethal Ischemic Damage in a Pig Model of DCD Liver Transplantation.

Compagnon P, Levesque E, Hentati H, Disabato M, Calderaro J, Feray C, Corlu A, Cohen JL, Ben Mosbah I, Azoulay D.

Transplantation. 2017 Jul;101(7):e205-e213. doi: 10.1097/TP.0000000000001764.

11.

Machine perfusion preservation versus static cold storage for deceased donor kidney transplantation.

Tingle SJ, Figueiredo RS, Moir JA, Goodfellow M, Talbot D, Wilson CH.

Cochrane Database Syst Rev. 2019 Mar 15;3:CD011671. doi: 10.1002/14651858.CD011671.pub2.

PMID:
30875082
12.

Impact of machine perfusion preservation of liver grafts from donation after cardiac death.

Matsuno N, Uchida K, Furukawa H.

Transplant Proc. 2014 May;46(4):1099-103. doi: 10.1016/j.transproceed.2013.11.135. Review.

PMID:
24815138
13.

One hour hypothermic oxygenated perfusion (HOPE) protects nonviable liver allografts donated after cardiac death.

de Rougemont O, Breitenstein S, Leskosek B, Weber A, Graf R, Clavien PA, Dutkowski P.

Ann Surg. 2009 Nov;250(5):674-83. doi: 10.1097/SLA.0b013e3181bcb1ee.

PMID:
19806056
14.

Hypothermic machine perfusion in liver transplantation.

Schlegel A, Kron P, Dutkowski P.

Curr Opin Organ Transplant. 2016 Jun;21(3):308-14. doi: 10.1097/MOT.0000000000000303. Review.

15.

Transplantation of high-risk donor livers after resuscitation and viability assessment using a combined protocol of oxygenated hypothermic, rewarming and normothermic machine perfusion: study protocol for a prospective, single-arm study (DHOPE-COR-NMP trial).

de Vries Y, Berendsen TA, Fujiyoshi M, van den Berg AP, Blokzijl H, de Boer MT, van der Heide F, de Kleine RHJ, van Leeuwen OB, Matton APM, Werner MJM, Lisman T, de Meijer VE, Porte R.

BMJ Open. 2019 Aug 15;9(8):e028596. doi: 10.1136/bmjopen-2018-028596.

16.

Donation after cardio-circulatory death liver transplantation.

Le Dinh H, de Roover A, Kaba A, Lauwick S, Joris J, Delwaide J, Honoré P, Meurisse M, Detry O.

World J Gastroenterol. 2012 Sep 7;18(33):4491-506. doi: 10.3748/wjg.v18.i33.4491.

17.

HOPE for human liver grafts obtained from donors after cardiac death.

Dutkowski P, Schlegel A, de Oliveira M, Müllhaupt B, Neff F, Clavien PA.

J Hepatol. 2014 Apr;60(4):765-72. doi: 10.1016/j.jhep.2013.11.023. Epub 2013 Dec 1.

PMID:
24295869
18.

Combined liver-kidney perfusion enhances protective effects of normothermic perfusion on liver grafts from donation after cardiac death.

He X, Ji F, Zhang Z, Tang Y, Yang L, Huang S, Li W, Su Q, Xiong W, Zhu Z, Wang L, Lv L, Yao J, Zhang L, Zhang L, Guo Z.

Liver Transpl. 2018 Jan;24(1):67-79. doi: 10.1002/lt.24954.

19.

Opposite acute potassium and sodium shifts during transplantation of hypothermic machine perfused donor livers.

Burlage LC, Hessels L, van Rijn R, Matton APM, Fujiyoshi M, van den Berg AP, Reyntjens KMEM, Meyer P, de Boer MT, de Kleine RHJ, Nijsten MW, Porte RJ.

Am J Transplant. 2019 Apr;19(4):1061-1071. doi: 10.1111/ajt.15173. Epub 2018 Dec 4.

20.

A novel combination technique of cold crystalloid perfusion but not cold storage facilitates transplantation of canine hearts donated after circulatory death.

Rosenfeldt F, Ou R, Salamonsen R, Marasco S, Zimmet A, Byrne J, Cosic F, Saxena P, Esmore D.

J Heart Lung Transplant. 2016 Nov;35(11):1358-1364. doi: 10.1016/j.healun.2016.03.015. Epub 2016 Apr 1.

PMID:
27311376

Supplemental Content

Support Center