Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 100

1.

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies.

Kaiser A, Eley JG, Onyeuku NE, Rice SR, Wright CC, McGovern NE, Sank M, Zhu M, Vujaskovic Z, Simone CB 2nd, Hussain A.

J Vis Exp. 2019 Feb 6;(144). doi: 10.3791/58372.

PMID:
30799838
2.

Spatially fractionated (GRID) radiation therapy using proton pencil beam scanning (PBS): Feasibility study and clinical implementation.

Gao M, Mohiuddin MM, Hartsell WF, Pankuch M.

Med Phys. 2018 Apr;45(4):1645-1653. doi: 10.1002/mp.12807. Epub 2018 Mar 1.

PMID:
29431867
3.

Proton therapy in the clinic.

DeLaney TF.

Front Radiat Ther Oncol. 2011;43:465-85. doi: 10.1159/000322511. Epub 2011 May 20. Review.

PMID:
21625169
4.

Considerations when treating lung cancer with passive scatter or active scanning proton therapy.

St James S, Grassberger C, Lu HM.

Transl Lung Cancer Res. 2018 Apr;7(2):210-215. doi: 10.21037/tlcr.2018.04.01. Review.

5.

Recent advances in light ion radiation therapy.

Brahme A.

Int J Radiat Oncol Biol Phys. 2004 Feb 1;58(2):603-16. Review.

PMID:
14751534
6.

Proton therapy - Present and future.

Mohan R, Grosshans D.

Adv Drug Deliv Rev. 2017 Jan 15;109:26-44. doi: 10.1016/j.addr.2016.11.006. Epub 2016 Dec 3. Review.

7.

Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions.

Zeng C, Giantsoudi D, Grassberger C, Goldberg S, Niemierko A, Paganetti H, Efstathiou JA, Trofimov A.

Med Phys. 2013 May;40(5):051708. doi: 10.1118/1.4801897.

8.

Consistency in quality correction factors for ionization chamber dosimetry in scanned proton beam therapy.

Sorriaux J, Testa M, Paganetti H, Bertrand D, Lee JA, Palmans H, Vynckier S, Sterpin E.

Med Phys. 2017 Sep;44(9):4919-4927. doi: 10.1002/mp.12434. Epub 2017 Aug 8.

PMID:
28656604
9.

SU-E-T-279: A Novel Electron-Beam Combined with Magnetic Field Application for Radiotherapy.

Alezra D, Nardi E, Koren S, Bragilovski D, Orion I.

Med Phys. 2012 Jun;39(6Part14):3767-3768. doi: 10.1118/1.4735347.

PMID:
28517301
10.

Proton beams to replace photon beams in radical dose treatments.

Suit H, Goldberg S, Niemierko A, Trofimov A, Adams J, Paganetti H, Chen GT, Bortfeld T, Rosenthal S, Loeffler J, Delaney T.

Acta Oncol. 2003;42(8):800-8.

PMID:
14968940
11.

Design of a fast multileaf collimator for radiobiological optimized IMRT with scanned beams of photons, electrons, and light ions.

Svensson R, Larsson S, Gudowska I, Holmberg R, Brahme A.

Med Phys. 2007 Mar;34(3):877-88.

PMID:
17441233
12.

Should positive phase III clinical trial data be required before proton beam therapy is more widely adopted? No.

Suit H, Kooy H, Trofimov A, Farr J, Munzenrider J, DeLaney T, Loeffler J, Clasie B, Safai S, Paganetti H.

Radiother Oncol. 2008 Feb;86(2):148-53. doi: 10.1016/j.radonc.2007.12.024. Epub 2008 Jan 30.

PMID:
18237800
13.

[Radiation Necrosis in the Upper Cervical Spinal Cord in a Patient Treated with Proton Therapy after Radical Resection of the Fourth Ventricle Ependymoma].

Mraček J, Mork J, Svoboda T, Ferda J, Přibáň V.

Klin Onkol. 2017 Summer;30(4):264-272. doi: 10.14735/amko2017264. Czech.

PMID:
28832173
14.

Study of the secondary neutral radiation in proton therapy: toward an indirect in vivo dosimetry.

Carnicer A, Letellier V, Rucka G, Angellier G, Sauerwein W, Herault J.

Med Phys. 2012 Dec;39(12):7303-16. doi: 10.1118/1.4765049.

PMID:
23231280
15.

Implementation of planar proton minibeam radiation therapy using a pencil beam scanning system: A proof of concept study.

De Marzi L, Patriarca A, Nauraye C, Hierso E, Dendale R, Guardiola C, Prezado Y.

Med Phys. 2018 Nov;45(11):5305-5316. doi: 10.1002/mp.13209. Epub 2018 Oct 12.

PMID:
30311639
16.

Proton radiation for localized prostate cancer.

Coen JJ, Zietman AL.

Nat Rev Urol. 2009 Jun;6(6):324-30. doi: 10.1038/nrurol.2009.83. Epub 2009 May 12. Review.

PMID:
19434101
17.

Measurements of neutron dose equivalent for a proton therapy center using uniform scanning proton beams.

Zheng Y, Liu Y, Zeidan O, Schreuder AN, Keole S.

Med Phys. 2012 Jun;39(6):3484-92. doi: 10.1118/1.4718685.

PMID:
22755728
18.

Dose to normal tissues outside the radiation therapy patient's treated volume: a review of different radiation therapy techniques.

Purdy JA.

Health Phys. 2008 Nov;95(5):666-76. doi: 10.1097/01.HP.0000326342.47348.06. Review.

PMID:
18849701
19.

Experimental evaluation of a spatial resampling technique to improve the accuracy of pencil-beam dose calculation in proton therapy.

Egashira Y, Nishio T, Matsuura T, Kameoka S, Uesaka M.

Med Phys. 2012 Jul;39(7):4104-14. doi: 10.1118/1.4722984.

PMID:
22830743
20.

Proton minibeam radiation therapy: Experimental dosimetry evaluation.

Peucelle C, Nauraye C, Patriarca A, Hierso E, Fournier-Bidoz N, Martínez-Rovira I, Prezado Y.

Med Phys. 2015 Dec;42(12):7108-13. doi: 10.1118/1.4935868.

PMID:
26632064

Supplemental Content

Support Center