Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 107

1.

High-Resolution Infrared Thermal Imaging of the Esophagus During Atrial Fibrillation Ablation as a Predictor of Endoscopically Detected Thermal Lesions.

Deneke T, Nentwich K, Berkovitz A, Sonne K, Ene E, Pavlov B, Fochler F, Bötsch AK, Kuhn R, Halbfaß P.

Circ Arrhythm Electrophysiol. 2018 Nov;11(11):e006681. doi: 10.1161/CIRCEP.118.006681.

PMID:
30376732
2.

Progression From Esophageal Thermal Asymptomatic Lesion to Perforation Complicating Atrial Fibrillation Ablation: A Single-Center Registry.

Halbfass P, Pavlov B, Müller P, Nentwich K, Sonne K, Barth S, Hamm K, Fochler F, Mügge A, Lüsebrink U, Kuhn R, Deneke T.

Circ Arrhythm Electrophysiol. 2017 Aug;10(8). pii: e005233. doi: 10.1161/CIRCEP.117.005233.

PMID:
28798021
3.

Higher incidence of esophageal lesions after ablation of atrial fibrillation related to the use of esophageal temperature probes.

Müller P, Dietrich JW, Halbfass P, Abouarab A, Fochler F, Szöllösi A, Nentwich K, Roos M, Krug J, Schade A, Mügge A, Deneke T.

Heart Rhythm. 2015 Jul;12(7):1464-9. doi: 10.1016/j.hrthm.2015.04.005. Epub 2015 Apr 3.

PMID:
25847474
4.

High-Resolution Infrared Thermography of Esophageal Temperature During Radiofrequency Ablation of Atrial Fibrillation.

Daly MG, Melton I, Roper G, Lim G, Crozier IG.

Circ Arrhythm Electrophysiol. 2018 Feb;11(2):e005667. doi: 10.1161/CIRCEP.117.005667.

PMID:
29449354
5.

Esophagus-Related Complications During Second-Generation Cryoballoon Ablation-Insight from Simultaneous Esophageal Temperature Monitoring from 2 Esophageal Probes.

Miyazaki S, Nakamura H, Taniguchi H, Takagi T, Iwasawa J, Watanabe T, Hachiya H, Hirao K, Iesaka Y.

J Cardiovasc Electrophysiol. 2016 Sep;27(9):1038-44. doi: 10.1111/jce.13015. Epub 2016 Jun 15.

PMID:
27221011
6.

Incidence of asymptomatic oesophageal lesions after atrial fibrillation ablation using an oesophageal temperature probe with insulated thermocouples: a comparative controlled study.

Halbfass P, Müller P, Nentwich K, Krug J, Roos M, Hamm K, Barth S, Szöllösi A, Mügge A, Schieffer B, Deneke T.

Europace. 2017 Mar 1;19(3):385-391. doi: 10.1093/europace/euw070. Erratum in: Europace. 2017 May 1;19(5):704.

PMID:
27540039
7.

Thermal esophageal lesions after radiofrequency catheter ablation of left atrial arrhythmias.

Halm U, Gaspar T, Zachäus M, Sack S, Arya A, Piorkowski C, Knigge I, Hindricks G, Husser D.

Am J Gastroenterol. 2010 Mar;105(3):551-6. doi: 10.1038/ajg.2009.625. Epub 2009 Nov 3.

PMID:
19888201
8.

Simplified method for esophagus protection during radiofrequency catheter ablation of atrial fibrillation--prospective study of 704 cases.

Mateos JC, Mateos EI, Peña TG, Lobo TJ, Mateos JC, Vargas RN, Pachón CT, Acosta JC.

Rev Bras Cir Cardiovasc. 2015 Mar-Apr;30(2):139-47. doi: 10.5935/1678-9741.20150009.

9.

Impact of surround flow catheter tip irrigation in contact force ablation on the incidence of asymptomatic oesophageal lesions after atrial fibrillation ablation: a prospective comparative study.

Halbfass P, Nentwich K, Krug J, Roos M, Sonne K, Ene E, Hamm K, Barth S, Szöllösi A, Fochler F, Mügge A, Lüsebrink U, Deneke T.

Europace. 2017 Jul 1;19(7):1116-1122. doi: 10.1093/europace/euw119.

PMID:
27353324
10.

Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study.

Leite LR, Santos SN, Maia H, Henz BD, Giuseppin F, Oliverira A, Zanatta AR, Peres AK, Novakoski C, Barreto JR, Vassalo F, d'Avila A, Singh SM.

Circ Arrhythm Electrophysiol. 2011 Apr;4(2):149-56. doi: 10.1161/CIRCEP.110.960328. Epub 2011 Feb 15.

PMID:
21325208
11.

Prevalence of esophageal ulceration after atrial fibrillation ablation with the hot balloon ablation catheter: what is the value of esophageal cooling?

Sohara H, Satake S, Takeda H, Yamaguchi Y, Nagasu N.

J Cardiovasc Electrophysiol. 2014 Jul;25(7):686-92. doi: 10.1111/jce.12394. Epub 2014 Mar 24.

PMID:
24576252
12.

Incidences of esophageal injury during esophageal temperature monitoring: a comparative study of a multi-thermocouple temperature probe and a deflectable temperature probe in atrial fibrillation ablation.

Kuwahara T, Takahashi A, Takahashi Y, Okubo K, Takagi K, Fujino T, Kusa S, Takigawa M, Watari Y, Yamao K, Nakashima E, Kawaguchi N, Hikita H, Sato A, Aonuma K.

J Interv Card Electrophysiol. 2014 Apr;39(3):251-7. doi: 10.1007/s10840-013-9868-5. Epub 2014 Feb 16.

PMID:
24532111
13.

Safe and effective ablation of atrial fibrillation: importance of esophageal temperature monitoring to avoid periesophageal nerve injury as a complication of pulmonary vein isolation.

Kuwahara T, Takahashi A, Kobori A, Miyazaki S, Takahashi Y, Takei A, Nozato T, Hikita H, Sato A, Aonuma K.

J Cardiovasc Electrophysiol. 2009 Jan;20(1):1-6. doi: 10.1111/j.1540-8167.2008.01280.x. Epub 2008 Sep 3.

PMID:
18775045
14.

Esophageal capsule endoscopy after radiofrequency catheter ablation for atrial fibrillation: documented higher risk of luminal esophageal damage with general anesthesia as compared with conscious sedation.

Di Biase L, Saenz LC, Burkhardt DJ, Vacca M, Elayi CS, Barrett CD, Horton R, Bai R, Siu A, Fahmy TS, Patel D, Armaganijan L, Wu CT, Kai S, Ching CK, Phillips K, Schweikert RA, Cummings JE, Arruda M, Saliba WI, Dodig M, Natale A.

Circ Arrhythm Electrophysiol. 2009 Apr;2(2):108-12. doi: 10.1161/CIRCEP.108.815266. Epub 2009 Feb 13.

PMID:
19808454
15.

Esophageal endoscopy results after pulmonary vein isolation using the single big cryoballoon technique.

Fürnkranz A, Chun KR, Metzner A, Nuyens D, Schmidt B, Burchard A, Tilz R, Ouyang F, Kuck KH.

J Cardiovasc Electrophysiol. 2010 Aug 1;21(8):869-74. doi: 10.1111/j.1540-8167.2010.01739.x. Epub 2010 Mar 5.

PMID:
20233270
16.

Identification of a high-risk population for esophageal injury during radiofrequency catheter ablation of atrial fibrillation: procedural and anatomical considerations.

Martinek M, Meyer C, Hassanein S, Aichinger J, Bencsik G, Schoefl R, Boehm G, Nesser HJ, Purerfellner H.

Heart Rhythm. 2010 Sep;7(9):1224-30. doi: 10.1016/j.hrthm.2010.02.027. Epub 2010 Feb 24.

PMID:
20188859
18.

Feasibility, safety, and efficacy of a novel preshaped nitinol esophageal deviator to successfully deflect the esophagus and ablate left atrium without esophageal temperature rise during atrial fibrillation ablation: The DEFLECT GUT study.

Parikh V, Swarup V, Hantla J, Vuddanda V, Dar T, Yarlagadda B, Di Biase L, Al-Ahmad A, Natale A, Lakkireddy D.

Heart Rhythm. 2018 Sep;15(9):1321-1327. doi: 10.1016/j.hrthm.2018.04.017. Epub 2018 Apr 18.

PMID:
29678784
19.

Utility of esophageal temperature monitoring during pulmonary vein isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation.

Deneke T, Bünz K, Bastian A, Päsler M, Anders H, Lehmann R, Meuser W, de Groot JR, Horlitz M, Haberkorn R, Mügge A, Shin DI.

J Cardiovasc Electrophysiol. 2011 Mar;22(3):255-61. doi: 10.1111/j.1540-8167.2010.01916.x. Epub 2010 Oct 11.

PMID:
20958829
20.

Esophageal temperature change and esophageal thermal lesions after pulmonary vein isolation using the novel endoscopic ablation system.

Metzner A, Schmidt B, Fuernkranz A, Wissner E, Tilz RR, Koester I, Konstantinidou M, Rillig A, Yoshiga Y, Mathew S, Ouyang F, Kuck KH.

Heart Rhythm. 2011 Jun;8(6):815-20. doi: 10.1016/j.hrthm.2011.01.022. Epub 2011 Jan 12.

PMID:
21236365

Supplemental Content

Support Center