Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 103

1.

Real-time in situ monitoring of poly(lactide-co-glycolide) coating of coronary stents using electrochemical impedance spectroscopy.

Zhong Q, Mao Q, Yan J, Liu W, Zhang T, Liu J.

J Biomed Mater Res B Appl Biomater. 2015 Apr;103(3):691-9. doi: 10.1002/jbm.b.33250.

PMID:
25052293
2.

[Preparation and in-vitro degradation of polylactide and poly(L-lactide-co-glycolide)].

Wei Z, Liu L, Zhang M, Yang F, Qi M.

Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008 Feb;25(1):122-6. Chinese.

PMID:
18435272
3.

Novel bioresorbable stent coating for drug release in congenital heart disease applications.

Goodfriend AC, Welch TR, Barker G, Ginther R Jr, Riegel MS, Reddy SV, Wang J, Nugent A, Forbess J.

J Biomed Mater Res A. 2015 May;103(5):1761-70. doi: 10.1002/jbm.a.35313.

PMID:
25196819
4.

In vitro and in vivo changes to PLGA/sirolimus coating on drug eluting stents.

Xi T, Gao R, Xu B, Chen L, Luo T, Liu J, Wei Y, Zhong S.

Biomaterials. 2010 Jul;31(19):5151-8. doi: 10.1016/j.biomaterials.2010.02.003.

PMID:
20382420
5.

Biodegradable poly(lactide-co-glycolide) coatings on magnesium alloys for orthopedic applications.

Ostrowski NJ, Lee B, Roy A, Ramanathan M, Kumta PN.

J Mater Sci Mater Med. 2013 Jan;24(1):85-96. doi: 10.1007/s10856-012-4773-5.

PMID:
23053803
6.

Combinatorial materials research applied to the development of new surface coatings X: a high-throughput electrochemical impedance spectroscopy method for screening organic coatings for corrosion inhibition.

He J, Bahr J, Chisholm BJ, Li J, Chen Z, Balbyshev SN, Bonitz V, Bierwagen GP.

J Comb Chem. 2008 Sep-Oct;10(5):704-13. doi: 10.1021/cc8000458.

PMID:
18582116
7.

Drug eluting stents based on Poly(ethylene carbonate): optimization of the stent coating process.

Bege N, Steinmüller SO, Kalinowski M, Reul R, Klaus S, Petersen H, Curdy C, Janek J, Kissel T.

Eur J Pharm Biopharm. 2012 Apr;80(3):562-70. doi: 10.1016/j.ejpb.2011.12.006.

PMID:
22209978
8.

A surface-eroding poly(1,3-trimethylene carbonate) coating for fully biodegradable magnesium-based stent applications: toward better biofunction, biodegradation and biocompatibility.

Wang J, He Y, Maitz MF, Collins B, Xiong K, Guo L, Yun Y, Wan G, Huang N.

Acta Biomater. 2013 Nov;9(10):8678-89. doi: 10.1016/j.actbio.2013.02.041.

PMID:
23467041
9.

Preparation, characterization and in vitro anticoagulation of emodin-eluting controlled biodegradable stent coatings.

Pan CJ, Wang J, Huang N.

Colloids Surf B Biointerfaces. 2010 Jun 1;77(2):155-60. doi: 10.1016/j.colsurfb.2010.01.019.

PMID:
20194006
10.

Development of a biodegradable sirolimus-eluting stent coated by ultrasonic atomizing spray.

Kim SJ, Park JG, Kim JH, Heo JS, Choi JW, Jang YS, Yoon J, Lee SJ, Kwon IK.

J Nanosci Nanotechnol. 2011 Jul;11(7):5689-97.

PMID:
22121592
11.

Paclitaxel releasing films consisting of poly(vinyl alcohol)-graft-poly(lactide-co-glycolide) and their potential as biodegradable stent coatings.

Westedt U, Wittmar M, Hellwig M, Hanefeld P, Greiner A, Schaper AK, Kissel T.

J Control Release. 2006 Mar 10;111(1-2):235-46.

PMID:
16466824
12.

The role of lipopolysaccharide on the electrochemical behavior of titanium.

Barão VA, Mathew MT, Assunção WG, Yuan JC, Wimmer MA, Sukotjo C.

J Dent Res. 2011 May;90(5):613-8. doi: 10.1177/0022034510396880.

PMID:
21335537
14.

Preparation and characterization of rapamycin-loaded PLGA coating stent.

Pan CJ, Tang JJ, Weng YJ, Wang J, Huang N.

J Mater Sci Mater Med. 2007 Nov;18(11):2193-8.

PMID:
17607513
15.

A mechanistic model for drug release in PLGA biodegradable stent coatings coupled with polymer degradation and erosion.

Zhu X, Braatz RD.

J Biomed Mater Res A. 2015 Jul;103(7):2269-79. doi: 10.1002/jbm.a.35357.

16.

Controllable biodegradability, drug release behavior and hemocompatibility of PTX-eluting magnesium stents.

Lu P, Fan H, Liu Y, Cao L, Wu X, Xu X.

Colloids Surf B Biointerfaces. 2011 Mar;83(1):23-8. doi: 10.1016/j.colsurfb.2010.10.038.

PMID:
21087842
17.

Improving the packing density of calcium phosphate coating on a magnesium alloy for enhanced degradation resistance.

Kannan MB.

J Biomed Mater Res A. 2013 May;101(5):1248-54. doi: 10.1002/jbm.a.34423.

PMID:
23008190
18.

Controlled degradation of multilayered poly(lactide-co-glycolide) films using electron beam irradiation.

Chia NK, Venkatraman SS, Boey FY, Cadart S, Loo JS.

J Biomed Mater Res A. 2008 Mar 15;84(4):980-7.

PMID:
17647238
19.

Evaluation of drug-eluting stents' coating durability--clinical and regulatory implications.

Levy Y, Mandler D, Weinberger J, Domb AJ.

J Biomed Mater Res B Appl Biomater. 2009 Oct;91(1):441-51. doi: 10.1002/jbm.b.31420.

PMID:
19489011
20.

Evaluation of a novel slow-release paclitaxel-eluting stent with a bioabsorbable polymeric surface coating.

Jabara R, Chronos N, Conway D, Molema W, Robinson K.

JACC Cardiovasc Interv. 2008 Feb;1(1):81-7. doi: 10.1016/j.jcin.2007.11.009.

Items per page

Supplemental Content

Support Center