Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 114

1.

Meta-analysis on biomechanical properties of meniscus repairs: are devices better than sutures?

M Buckland D, Sadoghi P, Wimmer MD, Vavken P, Pagenstert GI, Valderrabano V, Rosso C.

Knee Surg Sports Traumatol Arthrosc. 2015 Jan;23(1):83-9. doi: 10.1007/s00167-014-2966-9. Epub 2014 May 20. Review.

PMID:
24841938
2.

Biomechanical testing of suture-based meniscal repair devices containing ultrahigh-molecular-weight polyethylene suture: update 2011.

Barber FA, Herbert MA, Bava ED, Drew OR.

Arthroscopy. 2012 Jun;28(6):827-34. doi: 10.1016/j.arthro.2011.11.020. Epub 2012 Feb 7.

PMID:
22317797
3.
4.

A biomechanical comparison of the FasT-Fix meniscal repair suture system and the RapidLoc device in cadaver meniscus.

Kocabey Y, Chang HC, Brand JC Jr, Nawab A, Nyland J, Caborn DN.

Arthroscopy. 2006 Apr;22(4):406-13.

PMID:
16581453
5.

Biomechanical testing of new meniscal repair techniques containing ultra high-molecular weight polyethylene suture.

Barber FA, Herbert MA, Schroeder FA, Aziz-Jacobo J, Sutker MJ.

Arthroscopy. 2009 Sep;25(9):959-67. doi: 10.1016/j.arthro.2009.03.020.

PMID:
19732633
6.

A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.

Ramappa AJ, Chen A, Hertz B, Wexler M, Grimaldi Bournissaint L, DeAngelis JP, Nazarian A.

Am J Sports Med. 2014 Jan;42(1):194-9. doi: 10.1177/0363546513505190. Epub 2013 Oct 10.

PMID:
24114752
7.

Repair of peripheral vertical meniscus lesions in porcine menisci: in vitro biomechanical testing of 3 different meniscus repair devices.

Lee YH, Nyland J, Burden R, Caborn DN.

Am J Sports Med. 2013 May;41(5):1074-81. doi: 10.1177/0363546513479775. Epub 2013 Mar 8.

PMID:
23475943
8.

All-inside meniscal repair devices compared with their matched inside-out vertical mattress suture repair: introducing 10,000 and 100,000 loading cycles.

Rosso C, Müller S, Buckland DM, Schwenk T, Zimmermann S, de Wild M, Valderrabano V.

Am J Sports Med. 2014 Sep;42(9):2226-33. doi: 10.1177/0363546514538394. Epub 2014 Jun 25.

PMID:
24966304
9.

[Biodegradable meniscus fixations: a comparative biomechanical study].

Seil R, Rupp S, Jurecka C, Georg T, Kohn D.

Rev Chir Orthop Reparatrice Appar Mot. 2003 Feb;89(1):35-43. French.

PMID:
12610434
10.

Biomechanical testing of a shape memory alloy suture in a meniscal suture model.

Lamprakis AA, Fortis AP, Kostopoulos V, Vlasis K.

Arthroscopy. 2009 Jun;25(6):632-8. doi: 10.1016/j.arthro.2008.11.013. Epub 2009 Feb 12.

PMID:
19501294
11.

What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes.

Hardeman F, Corten K, Mylle M, Van Herck B, Verdonk R, Verdonk P, Bellemans J.

Knee Surg Sports Traumatol Arthrosc. 2015 Jan;23(1):59-64. doi: 10.1007/s00167-013-2495-y. Epub 2013 Apr 12.

PMID:
23579226
12.

Mechanical comparison of meniscal repair devices with mattress suture devices in vitro.

Aros BC, Pedroza A, Vasileff WK, Litsky AS, Flanigan DC.

Knee Surg Sports Traumatol Arthrosc. 2010 Nov;18(11):1594-8. doi: 10.1007/s00167-010-1188-z. Epub 2010 Jun 9.

PMID:
20532866
13.

Load to failure testing of new meniscal repair devices.

Barber FA, Herbert MA, Richards DP.

Arthroscopy. 2004 Jan;20(1):45-50.

PMID:
14716278
14.

Elongation and structural properties of meniscal repair using suture techniques in distraction and shear force scenarios: biomechanical evaluation using a cyclic loading protocol.

Zantop T, Temmig K, Weimann A, Eggers AK, Raschke MJ, Petersen W.

Am J Sports Med. 2006 May;34(5):799-805. Epub 2006 Mar 27.

PMID:
16567460
16.

A biomechanical comparison of the Mitek RapidLoc, Mitek Meniscal repair system, clearfix screws and vertical PDS and Ti-Cron sutures.

Naqui SZ, Thiryayi WA, Hopgood P, Ryan WG.

Knee. 2006 Mar;13(2):151-7. Epub 2005 Dec 7.

PMID:
16338137
17.

Cyclic testing of flexible all-inside meniscus suture anchors: biomechanical analysis.

Zantop T, Eggers AK, Musahl V, Weimann A, Petersen W.

Am J Sports Med. 2005 Mar;33(3):388-94.

PMID:
15716254
18.

A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.

Bhatia S, Civitarese DM, Turnbull TL, LaPrade CM, Nitri M, Wijdicks CA, LaPrade RF.

Am J Sports Med. 2016 Mar;44(3):639-45. doi: 10.1177/0363546515615565. Epub 2015 Dec 8.

PMID:
26646516
19.

Failure strengths of suture vs. biodegradable arrow and staple for meniscal repair: an in vitro study.

Walsh SP, Evans SL, O'Doherty DM, Barlow IW.

Knee. 2001 Jun;8(2):151-6.

PMID:
11337243
20.

Biomechanical comparison of the FasT-Fix meniscal repair suture system with vertical mattress sutures and meniscus arrows.

Borden P, Nyland J, Caborn DN, Pienkowski D.

Am J Sports Med. 2003 May-Jun;31(3):374-8.

PMID:
12750129

Supplemental Content

Support Center