Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 186

1.

Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE.

Roujol S, Weingärtner S, Foppa M, Chow K, Kawaji K, Ngo LH, Kellman P, Manning WJ, Thompson RB, Nezafat R.

Radiology. 2014 Sep;272(3):683-9. doi: 10.1148/radiol.14140296.

2.

Myocardial T1-mapping at 3T using saturation-recovery: reference values, precision and comparison with MOLLI.

Weingärtner S, Meßner NM, Budjan J, Loßnitzer D, Mattler U, Papavassiliu T, Zöllner FG, Schad LR.

J Cardiovasc Magn Reson. 2016 Nov 18;18(1):84.

3.

Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold.

Piechnik SK, Ferreira VM, Dall'Armellina E, Cochlin LE, Greiser A, Neubauer S, Robson MD.

J Cardiovasc Magn Reson. 2010 Nov 19;12:69. doi: 10.1186/1532-429X-12-69.

4.

Selection of magnetization catalyzation and readout methods for modified Look-Locker inversion recovery: a T1 mapping primer.

Cameron D, Higgins DM, Stehning C, Kouwenhoven M, Bouhrara M, Frenneaux MP, Dawson DK, Redpath TW.

Magn Reson Imaging. 2015 May;33(4):363-73. doi: 10.1016/j.mri.2015.02.004.

PMID:
25660643
5.

Instantaneous signal loss simulation (InSiL): an improved algorithm for myocardial T₁ mapping using the MOLLI sequence.

Shao J, Nguyen KL, Natsuaki Y, Spottiswoode B, Hu P.

J Magn Reson Imaging. 2015 Mar;41(3):721-9. doi: 10.1002/jmri.24599.

PMID:
24677371
6.
7.

Comparison of different cardiovascular magnetic resonance sequences for native myocardial T1 mapping at 3T.

Teixeira T, Hafyane T, Stikov N, Akdeniz C, Greiser A, Friedrich MG.

J Cardiovasc Magn Reson. 2016 Oct 4;18(1):65.

8.

Robust free-breathing SASHA T1 mapping with high-contrast image registration.

Chow K, Yang Y, Shaw P, Kramer CM, Salerno M.

J Cardiovasc Magn Reson. 2016 Aug 17;18(1):47. doi: 10.1186/s12968-016-0267-9.

9.

MOLLI and AIR T1 mapping pulse sequences yield different myocardial T1 and ECV measurements.

Hong K, Kim D.

NMR Biomed. 2014 Nov;27(11):1419-26. doi: 10.1002/nbm.3221.

10.

Saturation recovery single-shot acquisition (SASHA) for myocardial T(1) mapping.

Chow K, Flewitt JA, Green JD, Pagano JJ, Friedrich MG, Thompson RB.

Magn Reson Med. 2014 Jun;71(6):2082-95. doi: 10.1002/mrm.24878.

PMID:
23881866
11.

Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners.

Raman FS, Kawel-Boehm N, Gai N, Freed M, Han J, Liu CY, Lima JA, Bluemke DA, Liu S.

J Cardiovasc Magn Reson. 2013 Jul 26;15:64. doi: 10.1186/1532-429X-15-64.

12.

Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart.

Messroghli DR, Greiser A, Fröhlich M, Dietz R, Schulz-Menger J.

J Magn Reson Imaging. 2007 Oct;26(4):1081-6.

PMID:
17896383
13.

Comparison of T1 mapping techniques for ECV quantification. Histological validation and reproducibility of ShMOLLI versus multibreath-hold T1 quantification equilibrium contrast CMR.

Fontana M, White SK, Banypersad SM, Sado DM, Maestrini V, Flett AS, Piechnik SK, Neubauer S, Roberts N, Moon JC.

J Cardiovasc Magn Reson. 2012 Dec 28;14:88. doi: 10.1186/1532-429X-14-88.

14.

Saturation pulse design for quantitative myocardial T1 mapping.

Chow K, Kellman P, Spottiswoode BS, Nielles-Vallespin S, Arai AE, Salerno M, Thompson RB.

J Cardiovasc Magn Reson. 2015 Oct 1;17:84. doi: 10.1186/s12968-015-0187-0.

15.

Histological Validation of measurement of diffuse interstitial myocardial fibrosis by myocardial extravascular volume fraction from Modified Look-Locker imaging (MOLLI) T1 mapping at 3 T.

de Meester de Ravenstein C, Bouzin C, Lazam S, Boulif J, Amzulescu M, Melchior J, Pasquet A, Vancraeynest D, Pouleur AC, Vanoverschelde JL, Gerber BL.

J Cardiovasc Magn Reson. 2015 Jun 11;17:48. doi: 10.1186/s12968-015-0150-0.

16.

Characterization of T1 bias in skeletal muscle from fat in MOLLI and SASHA pulse sequences: Quantitative fat-fraction imaging with T1 mapping.

Larmour S, Chow K, Kellman P, Thompson RB.

Magn Reson Med. 2017 Jan;77(1):237-249. doi: 10.1002/mrm.26113.

PMID:
26860524
17.

T1 and extracellular volume mapping in the heart: estimation of error maps and the influence of noise on precision.

Kellman P, Arai AE, Xue H.

J Cardiovasc Magn Reson. 2013 Jun 21;15:56. doi: 10.1186/1532-429X-15-56.

18.

Free-breathing post-contrast three-dimensional T1 mapping: Volumetric assessment of myocardial T1 values.

Weingärtner S, Akçakaya M, Roujol S, Basha T, Stehning C, Kissinger KV, Goddu B, Berg S, Manning WJ, Nezafat R.

Magn Reson Med. 2015 Jan;73(1):214-22. doi: 10.1002/mrm.25124.

19.

Parallel simulations for QUAntifying RElaxation magnetic resonance constants (SQUAREMR): an example towards accurate MOLLI T1 measurements.

Xanthis CG, Bidhult S, Kantasis G, Heiberg E, Arheden H, Aletras AH.

J Cardiovasc Magn Reson. 2015 Nov 26;17:104. doi: 10.1186/s12968-015-0206-1.

20.

Free-breathing MOLLI: application to myocardial T(1) mapping.

Tsai JM, Huang TY, Tseng YS, Lin YR.

Med Phys. 2012 Dec;39(12):7291-302. doi: 10.1118/1.4764915.

PMID:
23231279
Items per page

Supplemental Content

Support Center