Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 108

1.

Atrial fibrillation burden estimates derived from intermittent rhythm monitoring are unreliable estimates of the true atrial fibrillation burden.

Charitos EI, Ziegler PD, Stierle U, Robinson DR, Graf B, Sievers HH, Hanke T.

Pacing Clin Electrophysiol. 2014 Sep;37(9):1210-8. doi: 10.1111/pace.12389. Epub 2014 Mar 25.

PMID:
24665972
2.

A comprehensive evaluation of rhythm monitoring strategies for the detection of atrial fibrillation recurrence: insights from 647 continuously monitored patients and implications for monitoring after therapeutic interventions.

Charitos EI, Stierle U, Ziegler PD, Baldewig M, Robinson DR, Sievers HH, Hanke T.

Circulation. 2012 Aug 14;126(7):806-14. doi: 10.1161/CIRCULATIONAHA.112.098079. Epub 2012 Jul 23. Erratum in: Circulation. 2012 Sep 25;126(13):e216.

3.

How often should we monitor for reliable detection of atrial fibrillation recurrence? Efficiency considerations and implications for study design.

Charitos EI, Ziegler PD, Stierle U, Robinson DR, Graf B, Sievers HH, Hanke T.

PLoS One. 2014 Feb 12;9(2):e89022. doi: 10.1371/journal.pone.0089022. eCollection 2014.

4.

Comparison of continuous versus intermittent monitoring of atrial arrhythmias.

Ziegler PD, Koehler JL, Mehra R.

Heart Rhythm. 2006 Dec;3(12):1445-52. Epub 2006 Aug 3.

PMID:
17161787
5.

The relationship between right ventricular pacing and atrial fibrillation burden and disease progression in patients with paroxysmal atrial fibrillation: the long-MinVPACE study.

Veasey RA, Arya A, Silberbauer J, Sharma V, Lloyd GW, Patel NR, Sulke AN.

Europace. 2011 Jun;13(6):815-20. doi: 10.1093/europace/euq463. Epub 2011 Jan 5.

6.

A detector for a chronic implantable atrial tachyarrhythmia monitor.

Sarkar S, Ritscher D, Mehra R.

IEEE Trans Biomed Eng. 2008 Mar;55(3):1219-24. doi: 10.1109/TBME.2007.903707.

PMID:
18334416
7.

Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter.

Mittal S, Pokushalov E, Romanov A, Ferrara M, Arshad A, Musat D, Preminger M, Sichrovsky T, Steinberg JS.

Heart Rhythm. 2013 Nov;10(11):1598-604. doi: 10.1016/j.hrthm.2013.07.044. Epub 2013 Jul 30.

PMID:
23911429
8.

Assessment of concomitant paroxysmal atrial fibrillation ablation in mitral valve surgery patients based on continuous monitoring: does a different lesion set matter?

Bogachev-Prokophiev A, Zheleznev S, Pivkin A, Pokushalov E, Romanov A, Nazarov V, Karaskov A.

Interact Cardiovasc Thorac Surg. 2014 Feb;18(2):177-81; discussion 182. doi: 10.1093/icvts/ivt461. Epub 2013 Nov 19.

9.

Clinical classifications of atrial fibrillation poorly reflect its temporal persistence: insights from 1,195 patients continuously monitored with implantable devices.

Charitos EI, PĆ¼rerfellner H, Glotzer TV, Ziegler PD.

J Am Coll Cardiol. 2014 Jul 1;63(25 Pt A):2840-8. doi: 10.1016/j.jacc.2014.04.019. Epub 2014 May 7.

10.

Burden of atrial fibrillation and poor rate control detected by continuous monitoring and the risk for heart failure hospitalization.

Sarkar S, Koehler J, Crossley GH, Tang WH, Abraham WT, Warman EN, Whellan DJ.

Am Heart J. 2012 Oct;164(4):616-24. doi: 10.1016/j.ahj.2012.06.020.

PMID:
23067922
11.

Assessing arrhythmia burden after catheter ablation of atrial fibrillation using an implantable loop recorder: the ABACUS study.

Kapa S, Epstein AE, Callans DJ, Garcia FC, Lin D, Bala R, Riley MP, Hutchinson MD, Gerstenfeld EP, Tzou W, Marchlinski FE, Frankel DS, Cooper JM, Supple G, Deo R, Verdino RJ, Patel VV, Dixit S.

J Cardiovasc Electrophysiol. 2013 Aug;24(8):875-81. doi: 10.1111/jce.12141. Epub 2013 Apr 11.

PMID:
23577826
12.

The relationship between high-frequency right ventricular pacing and paroxysmal atrial fibrillation burden.

Silberbauer J, Veasey RA, Freemantle N, Arya A, Boodhoo L, Sulke N.

Europace. 2009 Nov;11(11):1456-61. doi: 10.1093/europace/eup218. Epub 2009 Aug 6.

13.

Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial.

Hindricks G, Pokushalov E, Urban L, Taborsky M, Kuck KH, Lebedev D, Rieger G, PĆ¼rerfellner H; XPECT Trial Investigators.

Circ Arrhythm Electrophysiol. 2010 Apr;3(2):141-7. doi: 10.1161/CIRCEP.109.877852. Epub 2010 Feb 16.

14.

Identification of good responders to rhythm control of paroxysmal and persistent atrial fibrillation by transthoracic and transesophageal echocardiography.

Wang YC, Lin LC, Lin MS, Lai LP, Hwang JJ, Tseng YZ, Tseng CD, Lin JL.

Cardiology. 2005;104(4):202-9. Epub 2005 Sep 9.

PMID:
16155395
15.

Monitoring of atrial fibrillation burden after surgical ablation: relevancy of end-point criteria after radiofrequency ablation treatment of patients with lone atrial fibrillation.

Beukema R, Beukema WP, Sie HT, Misier AR, Delnoy PP, Elvan A.

Interact Cardiovasc Thorac Surg. 2009 Dec;9(6):956-9. doi: 10.1510/icvts.2009.209759. Epub 2009 Sep 17.

16.

Usefulness of continuous electrocardiographic monitoring for atrial fibrillation.

Camm AJ, Corbucci G, Padeletti L.

Am J Cardiol. 2012 Jul 15;110(2):270-6. doi: 10.1016/j.amjcard.2012.03.021. Epub 2012 Apr 12. Review.

PMID:
22503584
17.

Performance of an external transtelephonic loop recorder for automated detection of paroxysmal atrial fibrillation.

Velthuis BO, Bos J, Kraaier K, Stevenhagen J, van Opstal JM, van der Palen J, Scholten MF.

Ann Noninvasive Electrocardiol. 2013 Nov;18(6):564-70. doi: 10.1111/anec.12075. Epub 2013 Sep 9.

PMID:
24303971
18.

Effectiveness of atrial fibrillation monitor characteristics to predict severity of symptoms of atrial fibrillation.

Patel N, Chung EH, Mounsey JP, Schwartz JD, Pursell I, Gehi AK.

Am J Cardiol. 2014 May 15;113(10):1674-8. doi: 10.1016/j.amjcard.2014.02.022. Epub 2014 Mar 1.

PMID:
24698459
19.

Paroxysmal atrial fibrillation with silent episodes: intermittent versus continuous monitoring.

Doliwa PS, Rosenqvist M, Frykman V.

Scand Cardiovasc J. 2012 Jun;46(3):144-8. doi: 10.3109/14017431.2012.661873. Epub 2012 Feb 27.

PMID:
22292612
20.

Twenty-four-hour holter monitor follow-up does not provide accurate heart rhythm status after surgical atrial fibrillation ablation therapy: up to 12 months experience with a novel permanently implantable heart rhythm monitor device.

Hanke T, Charitos EI, Stierle U, Karluss A, Kraatz E, Graf B, Hagemann A, Misfeld M, Sievers HH.

Circulation. 2009 Sep 15;120(11 Suppl):S177-84. doi: 10.1161/CIRCULATIONAHA.108.838474.

Items per page

Supplemental Content

Write to the Help Desk