1.

Serial echocardiography using tissue Doppler and speckle tracking imaging to monitor right ventricular failure before and after left ventricular assist device surgery.

Kato TS, Jiang J, Schulze PC, Jorde U, Uriel N, Kitada S, Takayama H, Naka Y, Mancini D, Gillam L, Homma S, Farr M.

JACC Heart Fail. 2013 Jun;1(3):216-22. doi: 10.1016/j.jchf.2013.02.005. Epub 2013 Jun 3.

2.

Postoperative right ventricular failure after left ventricular assist device placement is predicted by preoperative echocardiographic structural, hemodynamic, and functional parameters.

Raina A, Seetha Rammohan HR, Gertz ZM, Rame JE, Woo YJ, Kirkpatrick JN.

J Card Fail. 2013 Jan;19(1):16-24. doi: 10.1016/j.cardfail.2012.11.001.

PMID:
23273590
3.

Preoperative three-dimensional echocardiography to assess risk of right ventricular failure after left ventricular assist device surgery.

Kiernan MS, French AL, DeNofrio D, Parmar YJ, Pham DT, Kapur NK, Pandian NG, Patel AR.

J Card Fail. 2015 Mar;21(3):189-97. doi: 10.1016/j.cardfail.2014.12.009. Epub 2014 Dec 20.

PMID:
25535957
4.

Assessment of right ventricular dysfunction predictors before the implantation of a left ventricular assist device in end-stage heart failure patients using echocardiographic measures (ARVADE): Combination of left and right ventricular echocardiographic variables.

Aissaoui N, Salem JE, Paluszkiewicz L, Morshuis M, Guerot E, Gorria GM, Fagon JY, Gummert J, Diebold B.

Arch Cardiovasc Dis. 2015 May;108(5):300-9. doi: 10.1016/j.acvd.2015.01.011. Epub 2015 Apr 8.

5.

The Right Ventricular Function After Left Ventricular Assist Device (RVF-LVAD) study: rationale and preliminary results.

Kalogeropoulos AP, Al-Anbari R, Pekarek A, Wittersheim K, Pernetz MA, Hampton A, Steinberg J, Georgiopoulou VV, Butler J, Vega JD, Smith AL.

Eur Heart J Cardiovasc Imaging. 2016 Apr;17(4):429-37. doi: 10.1093/ehjci/jev162. Epub 2015 Jul 9.

6.

Pulmonary artery pulsatility index predicts right ventricular failure after left ventricular assist device implantation.

Kang G, Ha R, Banerjee D.

J Heart Lung Transplant. 2016 Jan;35(1):67-73. doi: 10.1016/j.healun.2015.06.009. Epub 2015 Jun 17.

PMID:
26212656
7.

Usefulness of two-dimensional echocardiographic parameters of the left side of the heart to predict right ventricular failure after left ventricular assist device implantation.

Kato TS, Farr M, Schulze PC, Maurer M, Shahzad K, Iwata S, Homma S, Jorde U, Takayama H, Naka Y, Gillam L, Mancini D.

Am J Cardiol. 2012 Jan 15;109(2):246-51. doi: 10.1016/j.amjcard.2011.08.040. Epub 2011 Nov 14.

PMID:
22088200
8.

Right ventricular systolic and diastolic function as assessed by speckle-tracking echocardiography improve with prolonged isolated left ventricular assist device support.

Herod JW, Ambardekar AV.

J Card Fail. 2014 Jul;20(7):498-505. doi: 10.1016/j.cardfail.2014.04.017. Epub 2014 Apr 28.

PMID:
24785158
9.

Pulmonary Artery Pulsatility Index Is Associated With Right Ventricular Failure After Left Ventricular Assist Device Surgery.

Morine KJ, Kiernan MS, Pham DT, Paruchuri V, Denofrio D, Kapur NK.

J Card Fail. 2016 Feb;22(2):110-6. doi: 10.1016/j.cardfail.2015.10.019. Epub 2015 Nov 10.

PMID:
26564619
10.

Increased right-to-left ventricle diameter ratio is a strong predictor of right ventricular failure after left ventricular assist device.

Vivo RP, Cordero-Reyes AM, Qamar U, Garikipati S, Trevino AR, Aldeiri M, Loebe M, Bruckner BA, Torre-Amione G, Bhimaraj A, Trachtenberg BH, Estep JD.

J Heart Lung Transplant. 2013 Aug;32(8):792-9. doi: 10.1016/j.healun.2013.05.016.

PMID:
23856216
11.

Tissue Doppler imaging detects impaired biventricular performance shortly after congenital heart defect surgery.

Klitsie LM, Hazekamp MG, Roest AA, Van der Hulst AE, Gesink-van der Veer BJ, Kuipers IM, Blom NA, Ten Harkel AD.

Pediatr Cardiol. 2013 Mar;34(3):630-8. doi: 10.1007/s00246-012-0513-3. Epub 2012 Sep 22.

PMID:
23001517
12.

Validation of clinical scores for right ventricular failure prediction after implantation of continuous-flow left ventricular assist devices.

Kalogeropoulos AP, Kelkar A, Weinberger JF, Morris AA, Georgiopoulou VV, Markham DW, Butler J, Vega JD, Smith AL.

J Heart Lung Transplant. 2015 Dec;34(12):1595-603. doi: 10.1016/j.healun.2015.05.005. Epub 2015 Jun 1.

PMID:
26123950
13.

Independent and incremental role of quantitative right ventricular evaluation for the prediction of right ventricular failure after left ventricular assist device implantation.

Grant AD, Smedira NG, Starling RC, Marwick TH.

J Am Coll Cardiol. 2012 Aug 7;60(6):521-8. doi: 10.1016/j.jacc.2012.02.073.

14.

Risk factors predictive of right ventricular failure after left ventricular assist device implantation.

Drakos SG, Janicki L, Horne BD, Kfoury AG, Reid BB, Clayson S, Horton K, Haddad F, Li DY, Renlund DG, Fisher PW.

Am J Cardiol. 2010 Apr 1;105(7):1030-5. doi: 10.1016/j.amjcard.2009.11.026. Epub 2010 Feb 13.

PMID:
20346326
15.

Evaluation of Right Ventricular Function in the Management of Patients Referred for Left Ventricular Assist Device Therapy.

Cameli M, Sparla S, Focardi M, Righini FM, Solari M, Alvino F, Lisi M, D'Ascenzi F, Bernazzali S, Tsioulpas C, Sassi C, Dokollari A, Sani G, Maccherini M, Mondillo S.

Transplant Proc. 2015 Sep;47(7):2166-8. doi: 10.1016/j.transproceed.2015.02.032.

PMID:
26361669
16.

Right ventricular longitudinal strain correlates well with right ventricular stroke work index in patients with advanced heart failure referred for heart transplantation.

Cameli M, Lisi M, Righini FM, Tsioulpas C, Bernazzali S, Maccherini M, Sani G, Ballo P, Galderisi M, Mondillo S.

J Card Fail. 2012 Mar;18(3):208-15. doi: 10.1016/j.cardfail.2011.12.002. Epub 2012 Jan 13.

PMID:
22385941
17.

Three-dimensional echocardiography and 2D-3D speckle-tracking imaging in chronic pulmonary hypertension: diagnostic accuracy in detecting hemodynamic signs of right ventricular (RV) failure.

Vitarelli A, Mangieri E, Terzano C, Gaudio C, Salsano F, Rosato E, Capotosto L, D'Orazio S, Azzano A, Truscelli G, Cocco N, Ashurov R.

J Am Heart Assoc. 2015 Mar 19;4(3):e001584. doi: 10.1161/JAHA.114.001584.

18.

Left ventricular vs. biventricular mechanical support: Decision making and strategies for avoidance of right heart failure after left ventricular assist device implantation.

Dandel M, Krabatsch T, Falk V.

Int J Cardiol. 2015 Nov 1;198:241-50. doi: 10.1016/j.ijcard.2015.06.103. Epub 2015 Jul 2. Review.

PMID:
26232775
19.

Speckle tracking echocardiography as a new technique to evaluate right ventricular function in patients with left ventricular assist device therapy.

Cameli M, Lisi M, Righini FM, Focardi M, Lunghetti S, Bernazzali S, Marchetti L, Biagioli B, Galderisi M, Maccherini M, Sani G, Mondillo S.

J Heart Lung Transplant. 2013 Apr;32(4):424-30. doi: 10.1016/j.healun.2012.12.010.

PMID:
23498163
20.

Tricuspid annular motion as a predictor of severe right ventricular failure after left ventricular assist device implantation.

Puwanant S, Hamilton KK, Klodell CT, Hill JA, Schofield RS, Cleeton TS, Pauly DF, Aranda JM Jr.

J Heart Lung Transplant. 2008 Oct;27(10):1102-7. doi: 10.1016/j.healun.2008.07.022.

PMID:
18926401