Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 208

1.

Suture technique does not affect hemodynamic performance of the small supra-annular Trifecta bioprosthesis.

Ugur M, Byrne JG, Bavaria JE, Cheung A, Petracek M, Groh MA, Suri RM, Borger MA, Schaff HV.

J Thorac Cardiovasc Surg. 2014 Oct;148(4):1347-51. doi: 10.1016/j.jtcvs.2013.12.006. Epub 2014 Jan 2.

PMID:
24518226
2.

Comparison of early hemodynamic performance of 3 aortic valve bioprostheses.

Ugur M, Suri RM, Daly RC, Dearani JA, Park SJ, Joyce LD, Burkhart HM, Greason KL, Schaff HV.

J Thorac Cardiovasc Surg. 2014 Nov;148(5):1940-6. doi: 10.1016/j.jtcvs.2013.12.051. Epub 2014 Jan 15.

3.

Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus.

Wagner IM, Eichinger WB, Bleiziffer S, Botzenhardt F, Gebauer I, Guenzinger R, Bauernschmitt R, Lange R.

J Thorac Cardiovasc Surg. 2007 May;133(5):1234-41.

4.

Early hemodynamic evaluation of Trifecta and Freestyle bioprostheses in patients with a small aortic root: preliminary results from a prospective randomized study.

Tasca G, Stefano A, Giannico F, Lobiati E, Riva B, Galanti A, Triggiani M, Gamba A.

J Heart Valve Dis. 2014 Sep;23(5):633-41.

PMID:
25799714
5.

Simple interrupted suturing increases valve performance after aortic valve replacement with a small supra-annular bioprosthesis.

Tabata M, Shibayama K, Watanabe H, Sato Y, Fukui T, Takanashi S.

J Thorac Cardiovasc Surg. 2014 Jan;147(1):321-5. doi: 10.1016/j.jtcvs.2012.11.020. Epub 2012 Dec 8.

6.

The St Jude Medical Trifecta aortic pericardial valve: results from a global, multicenter, prospective clinical study.

Bavaria JE, Desai ND, Cheung A, Petracek MR, Groh MA, Borger MA, Schaff HV.

J Thorac Cardiovasc Surg. 2014 Feb;147(2):590-7. doi: 10.1016/j.jtcvs.2012.12.087. Epub 2013 Mar 7.

7.

The new St Jude Trifecta versus Carpentier-Edwards Perimount Magna and Magna Ease aortic bioprosthesis: is there a hemodynamic superiority?

Wendt D, Thielmann M, Plicht B, Aßmann J, Price V, Neuhäuser M, Jakob H.

J Thorac Cardiovasc Surg. 2014 May;147(5):1553-60. doi: 10.1016/j.jtcvs.2013.05.045. Epub 2013 Jul 16.

8.

Comprehensive hemodynamic comparison and frequency of patient-prosthesis mismatch between the St. Jude Medical Trifecta and Epic Bioprosthetic aortic valves.

Yadlapati A, Diep J, Barnes M, Grogan T, Bethencourt DM, Vorobiof G.

J Am Soc Echocardiogr. 2014 Jun;27(6):581-9. doi: 10.1016/j.echo.2014.01.002. Epub 2014 Feb 15.

PMID:
24534651
9.

Comprehensive hemodynamic performance and frequency of patient-prosthesis mismatch of the St. Jude Medical Trifecta bioprosthetic aortic valve.

Yadlapati A, Diep J, Barnes MJ, Grogan T, Bethencourt DM, Vorobiof G.

J Heart Valve Dis. 2014 Jul;23(4):516-23.

PMID:
25803979
10.

The Toronto root stentless valve in the subcoronary position is hemodynamically superior to the mosaic stented completely supra-annular bioprosthesis.

Bleiziffer S, Eichinger WB, Wagner I, Guenzinger R, Bauernschmitt R, Lange R.

J Heart Valve Dis. 2005 Nov;14(6):814-21; discussion 821.

PMID:
16359064
11.

Stented bioprosthetic valve hemodynamics: is the supra-annular implant better than the intra-annular?

Badano LP, Pavoni D, Musumeci S, Frassani R, Gianfagna P, Baldassi M, Tursi V, Mazzaro E, Zakja E, Fioretti PM, Livi U.

J Heart Valve Dis. 2006 Mar;15(2):238-46.

PMID:
16607907
12.

Do differences in early hemodynamic performance of current generation biologic aortic valves predict outcomes 1 year following surgery?

Thalji NM, Suri RM, Michelena HI, Greason KL, Dearani JA, Daly RC, Joyce LD, Stulak JM, Burkhart HM, Li Z, Schaff HV.

J Thorac Cardiovasc Surg. 2015 Jan;149(1):163-73.e2. doi: 10.1016/j.jtcvs.2014.09.027. Epub 2014 Sep 18.

13.

Hemodynamic performance during exercise of the new St. Jude Trifecta aortic bioprosthesis: results from a French multicenter study.

Levy F, Donal E, Bière L, Szymanski C, Remadi JP, Flécher E, Fouquet O, Leguerrier A, Tribouilloy C.

J Am Soc Echocardiogr. 2014 Jun;27(6):590-7. doi: 10.1016/j.echo.2014.01.022. Epub 2014 Mar 18.

PMID:
24656322
14.

Haemodynamic performance of the small supra-annular Trifecta bioprosthesis: results from a French multicentre study.

Fouquet O, Flecher E, Nzomvuama A, Remadi JP, Bière L, Donal E, Levy F, Dalmayrac E, Szymanski C, Leguerrier A, Tribouilloy C.

Interact Cardiovasc Thorac Surg. 2016 Apr;22(4):439-44. doi: 10.1093/icvts/ivv363. Epub 2016 Jan 10.

PMID:
27002012
15.

Early haemodynamic performance of a latest generation supra-annular aortic bioprosthesis: experience from a large single-centre series.

Deutsch MA, Prinzing A, Fiegl K, Wottke M, Badiu CC, Krane M, Goppel G, Bleiziffer S, Guenzinger R, Lange R.

Eur J Cardiothorac Surg. 2016 Jun;49(6):1691-8. doi: 10.1093/ejcts/ezv411. Epub 2015 Dec 10.

PMID:
26656235
16.

A prospective, randomized comparison of 3 contemporary bioprosthetic aortic valves: should hemodynamic performance influence device selection?

Suri RM, Michelena HI, Burkhart HM, Greason KL, Daly RC, Dearani JA, Park SJ, Joyce LD, Stulak JM, Sundt TM 3rd, Li Z, Schaff HV.

J Thorac Cardiovasc Surg. 2012 Dec;144(6):1387-95, 1398; discussion 1395-7. doi: 10.1016/j.jtcvs.2012.07.105.

17.

Matched Comparison of Two Different Biological Prostheses for Complete Supra-annular Aortic Valve Replacement.

Fiegl K, Deutsch MA, Rondak IC, Lange R, Guenzinger R.

Thorac Cardiovasc Surg. 2015 Sep;63(6):459-66. doi: 10.1055/s-0035-1548744. Epub 2015 Apr 20.

PMID:
25893918
18.

St. Jude Medical Trifecta™ aortic valve perioperative performance in 200 patients.

Permanyer E, Estigarribia AJ, Ysasi A, Herrero E, Semper O, Llorens R.

Interact Cardiovasc Thorac Surg. 2013 Oct;17(4):669-72. doi: 10.1093/icvts/ivt270. Epub 2013 Jul 3.

19.

Hemodynamic performance of the Medtronic Mosaic and Perimount Magna aortic bioprostheses: five-year results of a prospectively randomized study.

Dalmau MJ, González-Santos JM, Blázquez JA, Sastre JA, López-Rodríguez J, Bueno M, Castaño M, Arribas A.

Eur J Cardiothorac Surg. 2011 Jun;39(6):844-52; discussion 852. doi: 10.1016/j.ejcts.2010.11.015. Epub 2010 Dec 28.

PMID:
21193320
20.

Clinical performance of a sutureless aortic bioprosthesis: five-year results of the 3f Enable long-term follow-up study.

Englberger L, Carrel TP, Doss M, Sadowski J, Bartus K, Eckstein FF, Asch FM, Martens S.

J Thorac Cardiovasc Surg. 2014 Oct;148(4):1681-7. doi: 10.1016/j.jtcvs.2014.03.054. Epub 2014 Apr 4.

PMID:
24787699

Supplemental Content

Support Center