Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 133

1.

In-focus electrostatic Zach phase plate imaging for transmission electron microscopy with tunable phase contrast of frozen hydrated biological samples.

Frindt N, Oster M, Hettler S, Gamm B, Dieterle L, Kowalsky W, Gerthsen D, Schröder RR.

Microsc Microanal. 2014 Feb;20(1):175-83. doi: 10.1017/S1431927613013901.

PMID:
24382158
2.

A nanocrystalline Hilbert phase-plate for phase-contrast transmission electron microscopy.

Dries M, Hettler S, Gamm B, Müller E, Send W, Müller K, Rosenauer A, Gerthsen D.

Ultramicroscopy. 2014 Apr;139:29-37. doi: 10.1016/j.ultramic.2014.01.002.

PMID:
24556533
3.

Practical aspects of Boersch phase contrast electron microscopy of biological specimens.

Walter A, Muzik H, Vieker H, Turchanin A, Beyer A, Gölzhäuser A, Lacher M, Steltenkamp S, Schmitz S, Holik P, Kühlbrandt W, Rhinow D.

Ultramicroscopy. 2012 May;116:62-72. doi: 10.1016/j.ultramic.2012.03.009.

PMID:
22537744
4.

In-focus electron microscopy of frozen-hydrated biological samples with a Boersch phase plate.

Barton B, Rhinow D, Walter A, Schröder R, Benner G, Majorovits E, Matijevic M, Niebel H, Müller H, Haider M, Lacher M, Schmitz S, Holik P, Kühlbrandt W.

Ultramicroscopy. 2011 Dec;111(12):1696-705. doi: 10.1016/j.ultramic.2011.09.007.

PMID:
22088444
5.

Transfer doublet and an elaborated phase plate holder for 120 kV electron-phase microscope.

Hosokawa F, Danev R, Arai Y, Nagayama K.

J Electron Microsc (Tokyo). 2005 Aug;54(4):317-24.

PMID:
16123062
6.

Improved Zernike-type phase contrast for transmission electron microscopy.

Koeck PJ.

J Microsc. 2015 Jul;259(1):74-8. doi: 10.1111/jmi.12250.

PMID:
25865092
7.

Phase plates for transmission electron microscopy.

Danev R, Nagayama K.

Methods Enzymol. 2010;481:343-69. doi: 10.1016/S0076-6879(10)81014-6.

PMID:
20887864
8.

Optimizing phase contrast in transmission electron microscopy with an electrostatic (Boersch) phase plate.

Majorovits E, Barton B, Schultheiss K, Pérez-Willard F, Gerthsen D, Schröder RR.

Ultramicroscopy. 2007 Feb-Mar;107(2-3):213-26.

PMID:
16949755
9.

On-chip thin film Zernike phase plate for in-focus transmission electron microscopy imaging of organic materials.

Kuo PC, Chen IH, Chen CT, Lee KP, Chen CW, Lin CC, Chiu SW, Hsieh YF, Wang YL, Shiue J.

ACS Nano. 2013 Jan 22;7(1):465-70. doi: 10.1021/nn304511p.

PMID:
23268656
10.

Object-wave reconstruction by carbon film-based Zernike- and Hilbert-phase plate microscopy: a theoretical study not restricted to weak-phase objects.

Dries M, Schultheiss K, Gamm B, Rosenauer A, Schröder RR, Gerthsen D.

Ultramicroscopy. 2011 Jan;111(2):159-68. doi: 10.1016/j.ultramic.2010.10.009.

PMID:
21185461
11.

Phase contrast electron microscopy: development of thin-film phase plates and biological applications.

Nagayama K, Danev R.

Philos Trans R Soc Lond B Biol Sci. 2008 Jun 27;363(1500):2153-62. doi: 10.1098/rstb.2008.2268. Review.

12.

Phase TEM for biological imaging utilizing a Boersch electrostatic phase plate: theory and practice.

Shiue J, Chang CS, Huang SH, Hsu CH, Tsai JS, Chang WH, Wu YM, Lin YC, Kuo PC, Huang YS, Hwu Y, Kai JJ, Tseng FG, Chen FR.

J Electron Microsc (Tokyo). 2009 Jun;58(3):137-45. doi: 10.1093/jmicro/dfp006.

PMID:
19289850
13.

Towards an optimum design for electrostatic phase plates.

Walter A, Steltenkamp S, Schmitz S, Holik P, Pakanavicius E, Sachser R, Huth M, Rhinow D, Kühlbrandt W.

Ultramicroscopy. 2015 Jun;153:22-31. doi: 10.1016/j.ultramic.2015.01.005.

PMID:
25697462
14.

Contrast enhancement in the phase plate transmission electron microscopy using an objective lens with a long focal length.

Minoda H, Okabe T, Iijima H.

J Electron Microsc (Tokyo). 2011;60(5):337-43. doi: 10.1093/jmicro/dfr067.

PMID:
21880612
15.

Development of phase plates for electron microscopes and their biological application.

Nagayama K.

Eur Biophys J. 2008 Apr;37(4):345-58. doi: 10.1007/s00249-008-0264-5. Review.

PMID:
18259741
16.

Minimizing electrostatic charging of an aperture used to produce in-focus phase contrast in the TEM.

Glaeser RM, Sassolini S, Cambie R, Jin J, Cabrini S, Schmid AK, Danev R, Buijsse B, Csencsits R, Downing KH, Larson DM, Typke D, Han BG.

Ultramicroscopy. 2013 Dec;135:6-15. doi: 10.1016/j.ultramic.2013.05.023.

17.

Zernike phase contrast cryo-electron tomography of whole mounted frozen cells.

Fukuda Y, Nagayama K.

J Struct Biol. 2012 Feb;177(2):484-9. doi: 10.1016/j.jsb.2011.11.018.

PMID:
22119892
18.

Another 60 years in electron microscopy: development of phase-plate electron microscopy and biological applications.

Nagayama K.

J Electron Microsc (Tokyo). 2011;60 Suppl 1:S43-62. doi: 10.1093/jmicro/dfr037. Review.

PMID:
21844600
19.

Improving fabrication and application of Zach phase plates for phase-contrast transmission electron microscopy.

Hettler S, Gamm B, Dries M, Frindt N, Schröder RR, Gerthsen D.

Microsc Microanal. 2012 Oct;18(5):1010-5. doi: 10.1017/S1431927612001560.

PMID:
23058718
20.

Design of a hybrid double-sideband/single-sideband (schlieren) objective aperture suitable for electron microscopy.

Buijsse B, van Laarhoven FM, Schmid AK, Cambie R, Cabrini S, Jin J, Glaeser RM.

Ultramicroscopy. 2011 Dec;111(12):1688-95. doi: 10.1016/j.ultramic.2011.09.015.

Supplemental Content

Support Center