Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 97

1.

Procore and flexible 19 gauge needle can replace trucut biopsy needle?

Bang JY, Varadarajulu S.

Clin Endosc. 2013 Sep;46(5):503-5. doi: 10.5946/ce.2013.46.5.503. Epub 2013 Sep 30. Review.

2.

Endoscopic ultrasound-guided tissue acquisition.

Varadarajulu S, Hasan MK, Bang JY, Hebert-Magee S, Hawes RH.

Dig Endosc. 2014 Jan;26 Suppl 1:62-9. doi: 10.1111/den.12146. Epub 2013 Aug 28. Review.

PMID:
24033879
3.

Endoscopic ultrasound-guided fine-needle aspiration biopsy and trucut biopsy in gastroenterology - An overview.

Jenssen C, Dietrich CF.

Best Pract Res Clin Gastroenterol. 2009;23(5):743-59. doi: 10.1016/j.bpg.2009.05.006. Review.

PMID:
19744637
4.

Comparison of EUS-guided 19-gauge Trucut needle biopsy with EUS-guided fine-needle aspiration.

Varadarajulu S, Fraig M, Schmulewitz N, Roberts S, Wildi S, Hawes RH, Hoffman BJ, Wallace MB.

Endoscopy. 2004 May;36(5):397-401.

PMID:
15100946
5.

An animal experimental study to assess the core tissue acquisition ability of endoscopic ultrasound-guided histology needles.

Mukai S, Itoi T, Katanuma A, Irisawa A.

Endosc Ultrasound. 2017 Aug 24. doi: 10.4103/eus.eus_16_17. [Epub ahead of print]

6.

Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses.

Sakamoto H, Kitano M, Komaki T, Noda K, Chikugo T, Dote K, Takeyama Y, Das K, Yamao K, Kudo M.

J Gastroenterol Hepatol. 2009 Mar;24(3):384-90. doi: 10.1111/j.1440-1746.2008.05636.x. Epub 2008 Nov 20.

PMID:
19032453
7.

EUS-guided 22-gauge fine-needle aspiration versus core biopsy needle in the evaluation of solid pancreatic neoplasms.

Strand DS, Jeffus SK, Sauer BG, Wang AY, Stelow EB, Shami VM.

Diagn Cytopathol. 2014 Sep;42(9):751-8. doi: 10.1002/dc.23116. Epub 2014 Feb 18.

PMID:
24550162
8.

Assessment of the technical performance of the flexible 19-gauge EUS-FNA needle.

Varadarajulu S, Bang JY, Hebert-Magee S.

Gastrointest Endosc. 2012 Aug;76(2):336-43. doi: 10.1016/j.gie.2012.04.455.

PMID:
22817786
9.

A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition.

Bang JY, Hawes R, Varadarajulu S.

Endoscopy. 2016 Apr;48(4):339-49. doi: 10.1055/s-0034-1393354. Epub 2015 Nov 12. Review.

PMID:
26561917
10.
11.

Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles.

Yang MJ, Yim H, Hwang JC, Lee D, Kim YB, Lim SG, Kim SS, Kang JK, Yoo BM, Kim JH.

BMC Gastroenterol. 2015 Sep 29;15:122. doi: 10.1186/s12876-015-0352-9.

12.

Puncture of solid pancreatic tumors guided by endoscopic ultrasonography: a pilot study series comparing Trucut and 19-gauge and 22-gauge aspiration needles.

Itoi T, Itokawa F, Sofuni A, Nakamura K, Tsuchida A, Yamao K, Kawai T, Moriyasu F.

Endoscopy. 2005 Apr;37(4):362-6.

PMID:
15824948
13.

Endoscopic ultrasound-guided FNA and ProCore biopsy in sampling pancreatic and intra-abdominal masses.

Dwyer J, Pantanowitz L, Ohori NP, Pai RK, Vrbin C, Brand RE, Monaco SE.

Cancer Cytopathol. 2016 Feb;124(2):110-21. doi: 10.1002/cncy.21623. Epub 2015 Oct 2.

14.

A comparative needle study: EUS-FNA procedures using the HD ProCore(™) and EchoTip(®) 22-gauge needle types.

Witt BL, Adler DG, Hilden K, Layfield LJ.

Diagn Cytopathol. 2013 Dec;41(12):1069-74. doi: 10.1002/dc.22971. Epub 2013 Mar 20.

PMID:
23513000
15.

Endoscopic ultrasound-guided tissue sampling by combined fine needle aspiration and trucut needle biopsy: a prospective study.

Wittmann J, Kocjan G, Sgouros SN, Deheragoda M, Pereira SP.

Cytopathology. 2006 Feb;17(1):27-33.

PMID:
16417562
16.

Comparison of endoscopic ultrasound guided 22-gauge core needle with standard 25-gauge fine-needle aspiration for diagnosing solid pancreatic lesions.

Berzosa M, Villa N, El-Serag HB, Sejpal DV, Patel KK.

Endosc Ultrasound. 2015 Jan-Mar;4(1):28-33. doi: 10.4103/2303-9027.151320.

17.

Endoscopic ultrasound-guided tissue sampling: How can we improve the results?

Alper E, Onur İ, Arabul M, Ünsal B.

Turk J Gastroenterol. 2016 Jan;27(1):1-3. doi: 10.5152/tjg.2015.150497. Review.

18.

Prospective evaluation of the optimal number of 25-gauge needle passes for endoscopic ultrasound-guided fine-needle aspiration biopsy of solid pancreatic lesions in the absence of an onsite cytopathologist.

Suzuki R, Irisawa A, Bhutani MS, Hikichi T, Takagi T, Sato A, Sato M, Ikeda T, Watanabe K, Nakamura J, Tasaki K, Obara K, Ohira H.

Dig Endosc. 2012 Nov;24(6):452-6. doi: 10.1111/j.1443-1661.2012.01311.x. Epub 2012 Apr 10.

PMID:
23078439
19.

Feasibility and Diagnostic Yield of Endoscopic Ultrasonography-Guided Fine Needle Biopsy With a New Core Biopsy Needle Device in Patients With Gastric Subepithelial Tumors.

Lee M, Min BH, Lee H, Ahn S, Lee JH, Rhee PL, Kim JJ, Sohn TS, Kim S, Kim KM.

Medicine (Baltimore). 2015 Oct;94(40):e1622. doi: 10.1097/MD.0000000000001622.

20.

Endoscopic ultrasound-guided fine needle aspiration in submucosal lesion.

Moon JS.

Clin Endosc. 2012 Jun;45(2):117-23. doi: 10.5946/ce.2012.45.2.117. Epub 2012 Jun 30.

Supplemental Content

Support Center