Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 87

1.

Monte Carlo dosimetric study of the medium dose rate CSM40 source.

Vijande J, Granero D, Perez-Calatayud J, Ballester F.

Appl Radiat Isot. 2013 Dec;82:283-8. doi: 10.1016/j.apradiso.2013.09.003. Epub 2013 Sep 18.

PMID:
24121444
2.

Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

Campos LT, de Almeida CE.

PLoS One. 2015 Sep 29;10(9):e0139032. doi: 10.1371/journal.pone.0139032. eCollection 2015.

3.

Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE.

Casado FJ, García-Pareja S, Cenizo E, Mateo B, Bodineau C, Galán P.

Phys Med. 2010;26(3):132-9. doi: 10.1016/j.ejmp.2009.11.001. Epub 2010 Jan 14.

PMID:
20034828
4.

EGSnrc-based Monte Carlo dosimetry of CSA1 and CSA2 137Cs brachytherapy source models.

Selvam TP, Sahoo S, Vishwakarma RS.

Med Phys. 2009 Sep;36(9):3870-9.

PMID:
19810459
5.

Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism.

Ho Than MT, Munro Iii JJ, Medich DC.

J Appl Clin Med Phys. 2015 May 8;16(3):5270. doi: 10.1120/jacmp.v16i3.5270.

PMID:
26103489
6.

SU-E-T-467: Monte Carlo Dosimetric Study of the New Flexisource Co-60 High Dose Rate Source.

Vijande J, Granero D, Perez-Calatayud J, Ballester F.

Med Phys. 2012 Jun;39(6Part17):3812. doi: 10.1118/1.4735556.

PMID:
28517443
8.

Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source.

Vijande J, Granero D, Perez-Calatayud J, Ballester F.

J Contemp Brachytherapy. 2012 Mar;4(1):34-44. doi: 10.5114/jcb.2012.27950. Epub 2012 Mar 30.

9.

Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source.

Granero D, Pérez-Calatayud J, Ballester F.

Radiother Oncol. 2005 Jul;76(1):79-85.

PMID:
16019091
10.

Monte Carlo dosimetric study of the BEBIG Co-60 HDR source.

Ballester F, Granero D, Pérez-Calatayud J, Casal E, Agramunt S, Cases R.

Phys Med Biol. 2005 Nov 7;50(21):N309-16. Epub 2005 Oct 12.

PMID:
16237230
11.

Dosimetric characterization of the (60)Co BEBIG Co0.A86 high dose rate brachytherapy source using PENELOPE.

Guerrero R, Almansa JF, Torres J, Lallena AM.

Phys Med. 2014 Dec;30(8):960-7. doi: 10.1016/j.ejmp.2014.06.039. Epub 2014 Jul 19.

PMID:
25047841
12.

Monte Carlo simulation of COMS ophthalmic applicators loaded with Bebig I25.S16 seeds and comparison with planning system predictions.

Miras H, Terrón JA, Lallena AM.

Phys Med. 2013 Nov;29(6):670-6. doi: 10.1016/j.ejmp.2012.07.003. Epub 2012 Jul 31.

PMID:
22858007
13.

Dosimetry for 131Cs and 125I seeds in solid water phantom using radiochromic EBT film.

Chiu-Tsao ST, Napoli JJ, Davis SD, Hanley J, Rivard MJ.

Appl Radiat Isot. 2014 Sep;92:102-14. doi: 10.1016/j.apradiso.2014.06.014. Epub 2014 Jul 5.

PMID:
25038559
14.

Dosimetric characteristics, air-kerma strength calibration and verification of Monte Carlo simulation for a new Ytterbium-169 brachytherapy source.

Perera H, Williamson JF, Li Z, Mishra V, Meigooni AS.

Int J Radiat Oncol Biol Phys. 1994 Mar 1;28(4):953-70.

PMID:
8138449
15.

Evaluation of dosimetric parameters for various 192Ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation.

Devan K, Aruna P, Manigandan D, Bharanidharan G, Subbaiah KV, Sunny CS, Ganesan S.

Med Dosim. 2007 Winter;32(4):305-15.

PMID:
17980833
16.

Monte Carlo derivation of AAPM TG-43 dosimetric parameters for GZP6 Co-60 HDR sources.

Tabrizi SH, Asl AK, Azma Z.

Phys Med. 2012 Apr;28(2):153-60. doi: 10.1016/j.ejmp.2011.04.004. Epub 2011 May 31.

PMID:
21624844
17.

Dosimetric characteristics of the ¹⁹²Ir high-dose-rate afterloading brachytherapy source.

Sadeghi M, Taghdiri F, Saidi P.

Jpn J Radiol. 2011 Jun;29(5):324-9. doi: 10.1007/s11604-011-0562-1. Epub 2011 Jun 30.

PMID:
21717300
18.

A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: report of AAPM Task Group No. 138 and GEC-ESTRO.

DeWerd LA, Ibbott GS, Meigooni AS, Mitch MG, Rivard MJ, Stump KE, Thomadsen BR, Venselaar JL.

Med Phys. 2011 Feb;38(2):782-801.

19.

Monte Carlo characterization of 169Yb as a high-dose-rate source for brachytherapy application by FLUKA code.

Anjomrouz M, Sadeghi M, Haddadi A.

J Appl Clin Med Phys. 2013 Jul 8;14(4):4298. doi: 10.1120/jacmp.v14i4.4298.

PMID:
23835393
20.

A simplified analytical dose calculation algorithm accounting for tissue heterogeneity for low-energy brachytherapy sources.

Mashouf S, Lechtman E, Beaulieu L, Verhaegen F, Keller BM, Ravi A, Pignol JP.

Phys Med Biol. 2013 Sep 21;58(18):6299-315. doi: 10.1088/0031-9155/58/18/6299. Epub 2013 Aug 22.

PMID:
23965939

Supplemental Content

Support Center