Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 147

1.

Evaluation of closed-loop anesthesia delivery for propofol anesthesia in pediatric cardiac surgery.

Biswas I, Mathew PJ, Singh RS, Puri GD.

Paediatr Anaesth. 2013 Dec;23(12):1145-52. doi: 10.1111/pan.12265. Epub 2013 Oct 7.

PMID:
24118468
2.

Closed-loop isoflurane administration with bispectral index in open heart surgery: randomized controlled trial with manual control.

Madhavan JS, Puri GD, Mathew PJ.

Acta Anaesthesiol Taiwan. 2011 Dec;49(4):130-5. doi: 10.1016/j.aat.2011.11.007. Epub 2011 Dec 22.

3.

The accuracy and clinical feasibility of a new bayesian-based closed-loop control system for propofol administration using the bispectral index as a controlled variable.

De Smet T, Struys MM, Neckebroek MM, Van den Hauwe K, Bonte S, Mortier EP.

Anesth Analg. 2008 Oct;107(4):1200-10. doi: 10.1213/ane.0b013e31817bd1a6.

PMID:
18806028
4.

Comparison of closed loop vs. manual administration of propofol using the Bispectral index in cardiac surgery.

Agarwal J, Puri GD, Mathew PJ.

Acta Anaesthesiol Scand. 2009 Mar;53(3):390-7. doi: 10.1111/j.1399-6576.2008.01884.x.

PMID:
19243324
5.

Comparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus "standard practice" controlled administration.

Struys MM, De Smet T, Versichelen LF, Van De Velde S, Van den Broecke R, Mortier EP.

Anesthesiology. 2001 Jul;95(1):6-17.

PMID:
11465585
6.

A randomized controlled trial demonstrates that a novel closed-loop propofol system performs better hypnosis control than manual administration.

Hemmerling TM, Charabati S, Zaouter C, Minardi C, Mathieu PA.

Can J Anaesth. 2010 Aug;57(8):725-35. doi: 10.1007/s12630-010-9335-z. Epub 2010 Jun 9.

PMID:
20533013
7.

Robust closed-loop control of induction and maintenance of propofol anesthesia in children.

West N, Dumont GA, van Heusden K, Petersen CL, Khosravi S, Soltesz K, Umedaly A, Reimer E, Ansermino JM.

Paediatr Anaesth. 2013 Aug;23(8):712-9. doi: 10.1111/pan.12183. Epub 2013 May 13.

PMID:
23668370
8.

A Multicenter Evaluation of a Closed-Loop Anesthesia Delivery System: A Randomized Controlled Trial.

Puri GD, Mathew PJ, Biswas I, Dutta A, Sood J, Gombar S, Palta S, Tsering M, Gautam PL, Jayant A, Arora I, Bajaj V, Punia TS, Singh G.

Anesth Analg. 2016 Jan;122(1):106-14. doi: 10.1213/ANE.0000000000000769.

PMID:
25902324
9.

Feasibility of closed-loop titration of propofol and remifentanil guided by the bispectral monitor in pediatric and adolescent patients: a prospective randomized study.

Orliaguet GA, Benabbes Lambert F, Chazot T, Glasman P, Fischler M, Liu N.

Anesthesiology. 2015 Apr;122(4):759-67. doi: 10.1097/ALN.0000000000000577.

PMID:
25545655
10.

Automated titration of propofol and remifentanil decreases the anesthesiologist's workload during vascular or thoracic surgery: a randomized prospective study.

Dussaussoy C, Peres M, Jaoul V, Liu N, Chazot T, Picquet J, Fischler M, Beydon L.

J Clin Monit Comput. 2014 Feb;28(1):35-40. doi: 10.1007/s10877-013-9453-6. Epub 2013 Mar 15.

PMID:
23494090
11.

Closed-loop anaesthesia delivery system (CLADS) using bispectral index: a performance assessment study.

Puri GD, Kumar B, Aveek J.

Anaesth Intensive Care. 2007 Jun;35(3):357-62.

12.

Titration of propofol for anesthetic induction and maintenance guided by the bispectral index: closed-loop versus manual control: a prospective, randomized, multicenter study.

Liu N, Chazot T, Genty A, Landais A, Restoux A, McGee K, Laloë PA, Trillat B, Barvais L, Fischler M.

Anesthesiology. 2006 Apr;104(4):686-95.

PMID:
16571963
13.

Closed-loop control of anesthesia using the bispectral index in open heart surgery.

Puri GD, Mathew PJ.

Acta Anaesthesiol Taiwan. 2009 Sep;47(3):123-7. doi: 10.1016/S1875-4597(09)60038-2.

14.

A new closed-loop control system for isoflurane using bispectral index outperforms manual control.

Locher S, Stadler KS, Boehlen T, Bouillon T, Leibundgut D, Schumacher PM, Wymann R, Zbinden AM.

Anesthesiology. 2004 Sep;101(3):591-602.

PMID:
15329583
15.

Bispectral index-controlled postoperative sedation in cardiac surgery patients: a comparative trial between closed loop and manual administration of propofol.

Solanki A, Puri GD, Mathew PJ.

Eur J Anaesthesiol. 2010 Aug;27(8):708-13. doi: 10.1097/EJA.0b013e328335b2d4.

PMID:
20299990
16.
17.

Dexmedetomidine reduces propofol and remifentanil requirements during bispectral index-guided closed-loop anesthesia: a double-blind, placebo-controlled trial.

Le Guen M, Liu N, Tounou F, Augé M, Tuil O, Chazot T, Dardelle D, Laloë PA, Bonnet F, Sessler DI, Fischler M.

Anesth Analg. 2014 May;118(5):946-55. doi: 10.1213/ANE.0000000000000185.

PMID:
24722260
18.

Remifentanil, fentanyl, and cardiac surgery: a double-blinded, randomized, controlled trial of costs and outcomes.

Myles PS, Hunt JO, Fletcher H, Watts J, Bain D, Silvers A, Buckland MR.

Anesth Analg. 2002 Oct;95(4):805-12, table of contents.

PMID:
12351249
19.

Closed loop control of anaesthesia: an assessment of the bispectral index as the target of control.

Morley A, Derrick J, Mainland P, Lee BB, Short TG.

Anaesthesia. 2000 Oct;55(10):953-9.

20.

Feasibility of closed-loop titration of propofol and remifentanil guided by the spectral M-Entropy monitor.

Liu N, Le Guen M, Benabbes-Lambert F, Chazot T, Trillat B, Sessler DI, Fischler M.

Anesthesiology. 2012 Feb;116(2):286-95. doi: 10.1097/ALN.0b013e318242ad4f.

PMID:
22222478

Supplemental Content

Support Center