Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 110

1.

Impact of dry weight determined by calf bioimpedance ratio on carotid stiffness and left ventricular hypertrophy in hemodialysis patients.

Zhou YL, Liu J, Ma L, Sun F, Shen Y, Huang J, Cui T.

Artif Organs. 2014 Apr;38(4):327-34. doi: 10.1111/aor.12156. Epub 2013 Aug 27.

PMID:
23981096
2.

Bioimpedance-guided fluid management in maintenance hemodialysis: a pilot randomized controlled trial.

Onofriescu M, Hogas S, Voroneanu L, Apetrii M, Nistor I, Kanbay M, Covic AC.

Am J Kidney Dis. 2014 Jul;64(1):111-8. doi: 10.1053/j.ajkd.2014.01.420. Epub 2014 Feb 28.

PMID:
24583055
3.

Calf bioimpedance spectroscopy for determination of dry weight in hemodialysis patients: effects on hypertension and left ventricular hypertrophy.

Seibert E, Müller SG, Fries P, Pattmöller J, Kuss O, Heine GH, Girndt M, Schneider G, Kotanko P, Zhu F, Levin NW, Kuhlmann MK.

Kidney Blood Press Res. 2013;37(1):58-67. doi: 10.1159/000343400. Epub 2013 Mar 17.

4.

Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial.

Hur E, Usta M, Toz H, Asci G, Wabel P, Kahvecioglu S, Kayikcioglu M, Demirci MS, Ozkahya M, Duman S, Ok E.

Am J Kidney Dis. 2013 Jun;61(6):957-65. doi: 10.1053/j.ajkd.2012.12.017. Epub 2013 Feb 15.

PMID:
23415416
5.

Bioimpedance analysis and cardiovascular status in pediatric patients on chronic hemodialysis.

Paglialonga F, Ardissino G, Galli MA, Scarfia RV, Testa S, Edefonti A.

Hemodial Int. 2012 Oct;16 Suppl 1:S20-5. doi: 10.1111/j.1542-4758.2012.00743.x.

PMID:
23036032
6.

Adjustment of dry weight in hemodialysis patients using intradialytic continuous multifrequency bioimpedance of the calf.

Zhu F, Kuhlmann MK, Sarkar S, Kaitwatcharachai C, Khilnani R, Leonard EF, Greenwood R, Levin NW.

Int J Artif Organs. 2004 Feb;27(2):104-9.

PMID:
15061473
7.

Changes of the cardiac architectures and functions for chronic hemodialysis patients with dry weight determined by echocardiography.

Chang ST, Chen CC, Chen CL, Cheng HW, Chung CM, Yang TY.

Blood Purif. 2004;22(4):351-9. Epub 2004 Aug 3.

PMID:
15297785
8.

Calf bioimpedance ratio improves dry weight assessment and blood pressure control in hemodialysis patients.

Zhou YL, Liu J, Sun F, Ma LJ, Han B, Shen Y, Cui TG.

Am J Nephrol. 2010;32(2):109-16. doi: 10.1159/000315135. Epub 2010 Jun 18.

PMID:
20558982
9.

Effects of an increase in time vs. frequency on cardiovascular parameters in chronic hemodialysis patients.

Weinreich T, De los Ríos T, Gauly A, Passlick-Deetjen J.

Clin Nephrol. 2006 Dec;66(6):433-9.

PMID:
17176915
10.

Randomized trial of bioelectrical impedance analysis versus clinical criteria for guiding ultrafiltration in hemodialysis patients: effects on blood pressure, hydration status, and arterial stiffness.

Onofriescu M, Mardare NG, Segall L, Voroneanu L, Cuşai C, Hogaş S, Ardeleanu S, Nistor I, Prisadă OV, Sascău R, Covic A.

Int Urol Nephrol. 2012 Apr;44(2):583-91. doi: 10.1007/s11255-011-0022-y. Epub 2011 Jun 19.

PMID:
21688195
11.

Effective determination of dry weight by intradialytic bioimpedance analysis in hemodialysis.

Chongthanakorn K, Tiranathanagul K, Susantitaphong P, Praditpornsilpa K, Eiam-Ong S.

Blood Purif. 2009;27(3):235-41. doi: 10.1159/000199428. Epub 2009 Feb 4.

PMID:
19190396
12.

Left ventricular hypertrophy is associated with arterial stiffness and vascular calcification in hemodialysis patients.

Nitta K, Akiba T, Uchida K, Otsubo S, Otsubo Y, Takei T, Ogawa T, Yumura W, Kabaya T, Nihei H.

Hypertens Res. 2004 Jan;27(1):47-52.

13.

Determination of fluid status in haemodialysis patients with whole body and calf bioimpedance techniques.

Liu L, Zhu F, G Raimann J, Thijssen S, Sipahioglu MH, Wystrychowski G, Kitzler T, Tetta C, Wabel P, Kotanko P, Levin NW.

Nephrology (Carlton). 2012 Feb;17(2):131-40. doi: 10.1111/j.1440-1797.2011.01526.x.

PMID:
21951636
14.

Efficacy of losartan for improving insulin resistance and vascular remodeling in hemodialysis patients.

Sun F, Song Y, Liu J, Ma LJ, Shen Y, Huang J, Zhou YL.

Hemodial Int. 2016 Jan;20(1):22-30. doi: 10.1111/hdi.12327. Epub 2015 Jun 24.

PMID:
26104969
15.

Estimation of body composition and normal fluid status using a calf bioimpedance technique.

Zhu F, Levin NW.

Blood Purif. 2015;39(1-3):25-31. doi: 10.1159/000368937. Epub 2015 Jan 20.

16.

Association between left ventricular hypertrophy and changes in arterial stiffness during hypertensive treatment.

Masugata H, Senda S, Inukai M, Himoto T, Hosomi N, Murao K, Okada H, Goda F.

Clin Exp Hypertens. 2014;36(4):258-62. doi: 10.3109/10641963.2013.810229. Epub 2013 Jul 12.

PMID:
23848250
17.

Estimation of normal hydration in dialysis patients using whole body and calf bioimpedance analysis.

Zhu F, Kotanko P, Handelman GJ, Raimann JG, Liu L, Carter M, Kuhlmann MK, Seibert E, Leonard EF, Levin NW.

Physiol Meas. 2011 Jul;32(7):887-902. doi: 10.1088/0967-3334/32/7/S12. Epub 2011 Jun 7.

PMID:
21646705
18.

Association between extracellular water, left ventricular mass and hypertension in haemodialysis patients.

Fagugli RM, Pasini P, Quintaliani G, Pasticci F, Ciao G, Cicconi B, Ricciardi D, Santirosi PV, Buoncristiani E, Timio F, Valente F, Buoncristiani U.

Nephrol Dial Transplant. 2003 Nov;18(11):2332-8.

19.

Effects of short daily hemodialysis and extended standard hemodialysis on blood pressure and cardiac hypertrophy: a comparative study.

Fagugli RM, Pasini P, Pasticci F, Ciao G, Cicconi B, Buoncristiani U.

J Nephrol. 2006 Jan-Feb;19(1):77-83.

PMID:
16523430
20.

A method for the estimation of hydration state during hemodialysis using a calf bioimpedance technique.

Zhu F, Kuhlmann MK, Kotanko P, Seibert E, Leonard EF, Levin NW.

Physiol Meas. 2008 Jun;29(6):S503-16. doi: 10.1088/0967-3334/29/6/S42. Epub 2008 Jun 11.

PMID:
18544816
Items per page

Supplemental Content

Write to the Help Desk