Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 81

1.

Polyacrylamide phantom for self-actuating needle-tissue interaction studies.

Datla NV, Konh B, Koo JJ, Choi DJ, Yu Y, Dicker AP, Podder TK, Darvish K, Hutapea P.

Med Eng Phys. 2014 Jan;36(1):140-5. doi: 10.1016/j.medengphy.2013.07.004. Epub 2013 Aug 8.

PMID:
23932314
2.

Needle deflection estimation: prostate brachytherapy phantom experiments.

Sadjadi H, Hashtrudi-Zaad K, Fichtinger G.

Int J Comput Assist Radiol Surg. 2014 Nov;9(6):921-9. doi: 10.1007/s11548-014-0985-0. Epub 2014 Feb 17.

PMID:
24531917
3.

A model to predict deflection of bevel-tipped active needle advancing in soft tissue.

Datla NV, Konh B, Honarvar M, Podder TK, Dicker AP, Yu Y, Hutapea P.

Med Eng Phys. 2014 Mar;36(3):285-93. doi: 10.1016/j.medengphy.2013.11.006. Epub 2013 Dec 2.

PMID:
24296105
4.

Estimation of flexible needle deflection in layered soft tissues with different elastic moduli.

Lee H, Kim J.

Med Biol Eng Comput. 2014 Sep;52(9):729-40. doi: 10.1007/s11517-014-1173-7. Epub 2014 Jul 10.

PMID:
25008003
5.

A polyacrylamide gel phantom for radiofrequency ablation.

Bu-Lin Z, Bing H, Sheng-Li K, Huang Y, Rong W, Jia L.

Int J Hyperthermia. 2008 Nov;24(7):568-76. doi: 10.1080/02656730802104732.

PMID:
18608575
6.

A tissue mimicking polyacrylamide hydrogel phantom for visualizing thermal lesions generated by high intensity focused ultrasound.

Choi MJ, Guntur SR, Lee KI, Paeng DG, Coleman A.

Ultrasound Med Biol. 2013 Mar;39(3):439-48. doi: 10.1016/j.ultrasmedbio.2012.10.002. Epub 2013 Jan 9.

PMID:
23312531
7.

Gel phantom for use in high-intensity focused ultrasound dosimetry.

Lafon C, Zderic V, Noble ML, Yuen JC, Kaczkowski PJ, Sapozhnikov OA, Chavrier F, Crum LA, Vaezy S.

Ultrasound Med Biol. 2005 Oct;31(10):1383-9.

PMID:
16223642
8.

Measurement of the thermal conductivity of polyacrylamide tissue-equivalent material.

Davidson SR, Sherar MD.

Int J Hyperthermia. 2003 Sep-Oct;19(5):551-62.

PMID:
12944169
9.

Real-time optical measurement of biologically relevant thermal damage in tissue-mimicking hydrogels containing bovine serum albumin.

Nandlall SD, Schiffter HA, Vonhoff S, Bazán-Peregrino M, Arora M, Coussios CC.

Int J Hyperthermia. 2010;26(5):456-64. doi: 10.3109/02656731003789292.

PMID:
20569110
10.

Needle geometry, target migration and substrate interactions in high resolution.

Oldfield M, Leibinger A, Kaufmann PA, Bertucchi M, Beyrau F, Rodriguez y Baena F.

Conf Proc IEEE Eng Med Biol Soc. 2014;2014:852-5. doi: 10.1109/EMBC.2014.6943725.

PMID:
25570093
11.
12.

An improved tissue-mimicking polyacrylamide hydrogel phantom for visualizing thermal lesions with high-intensity focused ultrasound.

Guntur SR, Choi MJ.

Ultrasound Med Biol. 2014 Nov;40(11):2680-91. doi: 10.1016/j.ultrasmedbio.2014.06.010. Epub 2014 Sep 12.

PMID:
25220272
13.

Development of a dynamic model for bevel-tip flexible needle insertion into soft tissues.

Haddadi A, Hashtrudi-Zaad K.

Conf Proc IEEE Eng Med Biol Soc. 2011;2011:7478-82. doi: 10.1109/IEMBS.2011.6091845.

PMID:
22256068
14.
15.

Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study.

Blumenfeld P, Hata N, DiMaio S, Zou K, Haker S, Fichtinger G, Tempany CM.

J Magn Reson Imaging. 2007 Sep;26(3):688-94.

PMID:
17729363
16.

An investigation of the use of transmission ultrasound to measure acoustic attenuation changes in thermal therapy.

Parmar N, Kolios MC.

Med Biol Eng Comput. 2006 Jul;44(7):583-91. Epub 2006 Jun 10.

PMID:
16937194
17.

Needle-Tissue Interaction Forces for Bevel-Tip Steerable Needles.

Misra S, Reed KB, Douglas AS, Ramesh KT, Okamura AM.

Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron. 2008 Oct 19:224-231.

18.

Characterizing tissue stiffness at the tip of a rigid needle using an opto-mechanical force sensor.

Beekmans SV, Iannuzzi D.

Biomed Microdevices. 2016 Feb;18(1):15. doi: 10.1007/s10544-016-0039-1.

19.

Influence of acrylamide monomer addition to the acrylic denture-base resins on mechanical and physical properties.

Aydogan Ayaz E, Durkan R.

Int J Oral Sci. 2013 Dec;5(4):229-35. doi: 10.1038/ijos.2013.69. Epub 2013 Sep 13.

20.

Ultrasound visibility of needles used for regional nerve block: an in vitro study.

Schafhalter-Zoppoth I, McCulloch CE, Gray AT.

Reg Anesth Pain Med. 2004 Sep-Oct;29(5):480-8.

PMID:
15372394

Supplemental Content

Support Center