Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 165

1.

Estimating the lowest detectable dose of ionizing radiation by the cytokinesis-block micronucleus assay.

Tucker JD, Vadapalli M, Joiner MC, Ceppi M, Fenech M, Bonassi S.

Radiat Res. 2013 Sep;180(3):284-91. doi: 10.1667/RR3346.1. Epub 2013 Aug 9.

PMID:
23931722
2.

Estimating the lowest detectable dose of ionizing radiation by FISH whole-chromosome painting.

Tucker JD, Luckinbill LS.

Radiat Res. 2011 May;175(5):631-7. doi: 10.1667/RR2506.1. Epub 2011 Mar 28.

PMID:
21443424
3.

Dose estimation using dicentric chromosome assay and cytokinesis block micronucleus assay: comparison between manual and automated scoring in triage mode.

De Amicis A, De Sanctis S, Di Cristofaro S, Franchini V, Regalbuto E, Mammana G, Lista F.

Health Phys. 2014 Jun;106(6):787-97. doi: 10.1097/HP.0000000000000097.

PMID:
24776913
4.
5.

Micronucleus frequencies in cytokinesis-blocked human B lymphocytes after low dose gamma-irradiation.

Vral A, Louagie H, Thierens H, Philippé J, Cornelissen M, de Ridder L.

Int J Radiat Biol. 1998 May;73(5):549-55.

PMID:
9652813
6.

HUman MicroNucleus project: international database comparison for results with the cytokinesis-block micronucleus assay in human lymphocytes: I. Effect of laboratory protocol, scoring criteria, and host factors on the frequency of micronuclei.

Bonassi S, Fenech M, Lando C, Lin YP, Ceppi M, Chang WP, Holland N, Kirsch-Volders M, Zeiger E, Ban S, Barale R, Bigatti MP, Bolognesi C, Jia C, Di Giorgio M, Ferguson LR, Fucic A, Lima OG, Hrelia P, Krishnaja AP, Lee TK, Migliore L, Mikhalevich L, Mirkova E, Mosesso P, Müller WU, Odagiri Y, Scarffi MR, Szabova E, Vorobtsova I, Vral A, Zijno A.

Environ Mol Mutagen. 2001;37(1):31-45.

PMID:
11170240
7.

The cytokinesis-blocked micronucleus assay: dose estimation and inter-individual differences in the response to γ-radiation.

Antunes AC, Martins V, Cardoso J, Santos L, Monteiro Gil O.

Mutat Res Genet Toxicol Environ Mutagen. 2014 Jan 15;760:17-22. doi: 10.1016/j.mrgentox.2013.09.012. Epub 2013 Dec 24.

PMID:
24374146
8.

Cytokinesis-block micronucleus assay by manual and automated scoring: calibration curves and dose prediction.

De Sanctis S, De Amicis A, Di Cristofaro S, Franchini V, Regalbuto E, Mammana G, Lista F.

Health Phys. 2014 Jun;106(6):745-9. doi: 10.1097/HP.0000000000000052.

PMID:
24776908
9.

The cytokinesis-blocked micronucleus assay: dose-response calibration curve, background frequency in the population and dose estimation.

Rastkhah E, Zakeri F, Ghoranneviss M, Rajabpour MR, Farshidpour MR, Mianji F, Bayat M.

Radiat Environ Biophys. 2016 Mar;55(1):41-51. doi: 10.1007/s00411-015-0624-3. Epub 2015 Oct 27.

PMID:
26507139
10.

Adaption of the Cytokinesis-Block Micronucleus Cytome Assay for Improved Triage Biodosimetry.

Beinke C, Port M, Riecke A, Ruf CG, Abend M.

Radiat Res. 2016 May;185(5):461-72. doi: 10.1667/RR14294.1. Epub 2016 Apr 19.

PMID:
27092766
11.

Cytogenetic monitoring by use of the micronucleus assay among hospital workers exposed to low doses of ionizing radiation.

Sari-Minodier I, Orsière T, Auquier P, Martin F, Botta A.

Mutat Res. 2007 May 18;629(2):111-21. Epub 2007 Feb 23.

PMID:
17428723
12.

Validation of the cytokinesis-block micronucleus (CBMN) assay for use as a triage biological dosimetry tool.

McNamee JP, Flegal FN, Greene HB, Marro L, Wilkins RC.

Radiat Prot Dosimetry. 2009 Aug;135(4):232-42. doi: 10.1093/rpd/ncp119.

PMID:
19628702
13.

Response of human lymphocytes to proton radiation of 60 MeV compared to 250 kV X-rays by the cytokinesis-block micronucleus assay.

Miszczyk J, Rawojć K, Panek A, Swakoń J, Prasanna PG, Rydygier M.

Radiother Oncol. 2015 Apr;115(1):128-34. doi: 10.1016/j.radonc.2015.03.003. Epub 2015 Mar 24.

PMID:
25818831
14.

Validating high-throughput micronucleus analysis of peripheral reticulocytes for radiation biodosimetry: benchmark against dicentric and CBMN assays in a mouse model.

Chen Y, Tsai Y, Nowak I, Wang N, Hyrien O, Wilkins R, Ferrarotto C, Sun H, Dertinger SD.

Health Phys. 2010 Feb;98(2):218-27. doi: 10.1097/HP.0b013e3181abaae5.

PMID:
20065686
15.

Effect of dose rate on residual γ-H2AX levels and frequency of micronuclei in X-irradiated mouse lymphocytes.

Turner HC, Shuryak I, Taveras M, Bertucci A, Perrier JR, Chen C, Elliston CD, Johnson GW, Smilenov LB, Amundson SA, Brenner DJ.

Radiat Res. 2015 Mar;183(3):315-24. doi: 10.1667/RR13860.1. Epub 2015 Mar 4.

16.

Radiobiological effect of 99mTechnetium-MIBI in human peripheral blood lymphocytes: ex vivo study using micronucleus/FISH assay.

Taibi N, Aka P, Kirsch-Volders M, Bourgeois P, Frühling J, Szpireer C.

Cancer Lett. 2006 Feb 20;233(1):68-78. Epub 2005 Apr 22.

PMID:
16473669
17.

The micronucleus assay as a biological dosimeter of in vivo ionising radiation exposure.

Vral A, Fenech M, Thierens H.

Mutagenesis. 2011 Jan;26(1):11-7. doi: 10.1093/mutage/geq078. Review.

PMID:
21164177
18.

The micronucleus assay as a biological dosimeter in hospital workers exposed to low doses of ionizing radiation.

Ropolo M, Balia C, Roggieri P, Lodi V, Nucci MC, Violante FS, Silingardi P, Colacci A, Bolognesi C.

Mutat Res. 2012 Aug 30;747(1):7-13. doi: 10.1016/j.mrgentox.2012.02.014. Epub 2012 Apr 14.

PMID:
22525360
20.

Supplemental Content

Support Center