Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 97

1.

[Mechanism of lumen loss of the left circumflex ostium after main vessel stent implantation: observations by intravascular ultrasound].

Xiu J, Liao W, Liu B, Zhang X, Hou Y, Huang Z, Guo Z, Zhou Z, Cao S, Cui K.

Nan Fang Yi Ke Da Xue Xue Bao. 2013 Jul;33(7):1045-8. Chinese.

2.

Changes in left main bifurcation geometry after a single-stent crossover technique: an intravascular ultrasound study using direct imaging of both the left anterior descending and the left circumflex coronary arteries before and after intervention.

Kang SJ, Mintz GS, Kim WJ, Lee JY, Oh JH, Park DW, Lee SW, Kim YH, Lee CW, Park SW, Park SJ.

Circ Cardiovasc Interv. 2011 Aug;4(4):355-61. doi: 10.1161/CIRCINTERVENTIONS.110.961045. Epub 2011 Jun 28.

3.

Three-dimensional intravascular ultrasound evaluation of carina and plaque shift at the distal left main coronary artery bifurcation after treatment with a one-stent cross-over technique.

Xiu J, Choi SY, Mintz GS, Araki H, Masuda N, Morino Y, Sonoda S, Tahk SJ, Ochiai M, Maehara A.

Catheter Cardiovasc Interv. 2013 Jun 1;81(7):1142-9. doi: 10.1002/ccd.24681. Epub 2013 Feb 26.

PMID:
23008216
4.

Functional and morphological assessment of side branch after left main coronary artery bifurcation stenting with cross-over technique.

Kang SJ, Ahn JM, Kim WJ, Lee JY, Park DW, Lee SW, Kim YH, Lee CW, Park SW, Park SJ.

Catheter Cardiovasc Interv. 2014 Mar 1;83(4):545-52. doi: 10.1002/ccd.25057. Epub 2013 Nov 15.

PMID:
23765939
5.

Single-stent crossover technique from distal unprotected left main coronary artery to the left circumflex artery.

Naganuma T, Chieffo A, Basavarajaiah S, Takagi K, Costopoulos C, Latib A, Carlino M, Montorfano M, Bernelli C, Nakamura S, Colombo A.

Catheter Cardiovasc Interv. 2013 Nov 1;82(5):757-64. doi: 10.1002/ccd.24988. Epub 2013 Jun 14.

PMID:
23674385
7.

Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: intravascular ultrasound results of the AXXENT trial.

Hasegawa T, Ako J, Koo BK, Miyazawa A, Sakurai R, Chang H, Dens J, Verheye S, Grube E, Honda Y, Fitzgerald PJ.

Catheter Cardiovasc Interv. 2009 Jan 1;73(1):34-41. doi: 10.1002/ccd.21765.

PMID:
19089934
8.

Calcification analysis by intravascular ultrasound to define a predictor of left circumflex narrowing after cross-over stenting for unprotected left main bifurcation lesions.

Sato K, Naganuma T, Costopoulos C, Takebayashi H, Goto K, Miyazaki T, Yamane H, Hagikura A, Kikuta Y, Taniguchi M, Hiramatsu S, Latib A, Ito H, Haruta S, Colombo A.

Cardiovasc Revasc Med. 2014 Mar;15(2):80-5. doi: 10.1016/j.carrev.2014.01.014. Epub 2014 Feb 6.

PMID:
24684758
9.
10.

Intravascular ultrasound assessment of distal left main bifurcation disease: the importance of the polygon of confluence of the left main, left anterior descending, and left circumflex arteries.

Kang SJ, Mintz GS, Oh JH, Park DW, Lee SW, Kim YH, Lee CW, Park SW, Park SJ.

Catheter Cardiovasc Interv. 2013 Nov 1;82(5):737-45. doi: 10.1002/ccd.23263. Epub 2013 Mar 28.

PMID:
21805589
11.

Impact of kissing balloon inflation on the main vessel stent volume, area, and symmetry after side-branch dilation in patients with coronary bifurcation lesions: a serial volumetric intravascular ultrasound study.

Rahman S, Leesar T, Cilingiroglu M, Effat M, Arif I, Helmy T, Leesar MA.

JACC Cardiovasc Interv. 2013 Sep;6(9):923-31. doi: 10.1016/j.jcin.2013.04.019. Epub 2013 Aug 14.

12.

Hemodynamic impact of changes in bifurcation geometry after single-stent cross-over technique assessed by intravascular ultrasound and fractional flow reserve.

Kang SJ, Kim WJ, Lee JY, Park DW, Lee SW, Kim YH, Lee CW, Mintz GS, Park SW, Park SJ.

Catheter Cardiovasc Interv. 2013 Dec 1;82(7):1075-82. doi: 10.1002/ccd.24956. Epub 2013 Aug 1.

PMID:
23592548
13.

Intravascular ultrasound comparison of the self-expanding Sideguard stent in the side branch versus a balloon-expandable stent in the main vessel to assess mechanisms of acute lumen gain in bifurcation lesions.

Ma S, Maehara A, Hauptmann KE, Guagliumi G, Valsecchi O, Vassileva A, Appelman Y, Sangiorgi G, Prati F, Mintz GS.

Catheter Cardiovasc Interv. 2013 Nov 1;82(5):748-54. doi: 10.1002/ccd.24953. Epub 2013 Jun 26.

PMID:
23592513
14.

Intravascular ultrasound classification of plaque distribution in left main coronary artery bifurcations: where is the plaque really located?

Oviedo C, Maehara A, Mintz GS, Araki H, Choi SY, Tsujita K, Kubo T, Doi H, Templin B, Lansky AJ, Dangas G, Leon MB, Mehran R, Tahk SJ, Stone GW, Ochiai M, Moses JW.

Circ Cardiovasc Interv. 2010 Apr;3(2):105-12. doi: 10.1161/CIRCINTERVENTIONS.109.906016. Epub 2010 Mar 2.

15.
16.

Mechanism of Residual Lumen Stenosis at the Side Branch Ostium After Final Kissing Balloon Inflation: A Volumetric Intracoronary Ultrasound Study of Coronary Bifurcation Lesions.

Yamawaki M, Murasato Y, Kinoshita Y, Fujii K, Fujino Y, Shinke T, Takeda Y, Yamada S, Shimada Y, Tsukahara R, Muramatsu T, Suzuki T; J-REVERSE investigators.

J Interv Cardiol. 2016 Apr;29(2):188-96. doi: 10.1111/joic.12281. Epub 2016 Jan 29.

PMID:
26822855
17.

Serial intravascular ultrasound analysis comparing double kissing and classical crush stenting for coronary bifurcation lesions.

Chen SL, Mintz G, Kan J, Zhang JJ, Hu ZY, Ye F, Tian NL, Zhang JX, Xu T, Liu ZZ.

Catheter Cardiovasc Interv. 2011 Nov 1;78(5):729-36. doi: 10.1002/ccd.23110.

PMID:
21538789
18.

Preintervention angiographic and intravascular ultrasound predictors for side branch compromise after a single-stent crossover technique.

Kang SJ, Mintz GS, Kim WJ, Lee JY, Park DW, Lee SW, Kim YH, Lee CW, Park SW, Park SJ.

Am J Cardiol. 2011 Jun 15;107(12):1787-93. doi: 10.1016/j.amjcard.2011.02.323. Epub 2011 Apr 18.

PMID:
21507367
19.

Intravascular Ultrasound Classification of Plaque in Angiographic True Bifurcation Lesions of the Left Main Coronary Artery.

Li L, Dash D, Gai LY, Cao YS, Zhao Q, Wang YR, Zhang YJ, Zhang JX.

Chin Med J (Engl). 2016 Jul 5;129(13):1538-43. doi: 10.4103/0366-6999.184456.

20.

Usual dose of simvastatin does not inhibit plaque progression and lumen loss at the peri-stent reference segments after bare-metal stent implantation: a serial intravascular ultrasound analysis.

Hong YJ, Jeong MH, Choi YH, Ma EH, Ko JS, Lee MG, Park KH, Sim DS, Yoon NS, Youn HJ, Kim KH, Park HW, Kim JH, Ahn Y, Cho JG, Park JC, Kang JC.

Korean J Intern Med. 2010 Dec;25(4):356-63. doi: 10.3904/kjim.2010.25.4.356. Epub 2010 Nov 27.

Supplemental Content

Support Center