Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 109

1.

Effect of head contact on the rim of the cup on the offset loading and torque in hip joint replacement.

Liu F, Williams S, Jin Z, Fisher J.

Proc Inst Mech Eng H. 2013 Nov;227(11):1147-54. doi: 10.1177/0954411913496016.

PMID:
23886972
2.

Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.

Williams S, Butterfield M, Stewart T, Ingham E, Stone M, Fisher J.

Proc Inst Mech Eng H. 2003;217(2):147-53.

PMID:
12666782
3.

Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements.

Mak MM, Besong AA, Jin ZM, Fisher J.

Proc Inst Mech Eng H. 2002;216(6):403-8.

PMID:
12502004
4.

Wear of surface-engineered metal-on-metal bearings for hip prostheses under adverse conditions with the head loading on the rim of the cup.

Leslie I, Williams S, Isaac G, Hatto P, Ingham E, Fisher J.

Proc Inst Mech Eng H. 2013 Apr;227(4):345-9. doi: 10.1177/0954411912468542.

PMID:
23637209
5.

Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.

Al-Hajjar M, Fisher J, Tipper JL, Williams S, Jennings LM.

Proc Inst Mech Eng H. 2013 May;227(5):535-42. doi: 10.1177/0954411912474613.

PMID:
23637263
6.

Effect of microseparation on contact mechanics in metal-on-metal hip replacements-A finite element analysis.

Liu F, Williams S, Fisher J.

J Biomed Mater Res B Appl Biomater. 2015 Aug;103(6):1312-9. doi: 10.1002/jbm.b.33313.

7.

Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint.

Scholes SC, Burgess IC, Marsden HR, Unsworth A, Jones E, Smith N.

Proc Inst Mech Eng H. 2006 Jul;220(5):583-96.

PMID:
16898216
8.

The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups--finite element simulations and experimental tests.

Korhonen RK, Koistinen A, Konttinen YT, Santavirta SS, Lappalainen R.

Biomed Eng Online. 2005 May 17;4:32.

9.

[Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].

Morscher EW, Widmer KH, Bereiter H, Elke R, Schenk R.

Acta Chir Orthop Traumatol Cech. 2002;69(1):8-15. German.

PMID:
11951572
10.

Effect of cup inclination angle during microseparation and rim loading on the wear of BIOLOX® delta ceramic-on-ceramic total hip replacement.

Al-Hajjar M, Leslie IJ, Tipper J, Williams S, Fisher J, Jennings LM.

J Biomed Mater Res B Appl Biomater. 2010 Nov;95(2):263-8. doi: 10.1002/jbm.b.31708.

PMID:
20860044
11.

Effect of cup abduction angle and head lateral microseparation on contact stresses in ceramic-on-ceramic total hip arthroplasty.

Sariali E, Stewart T, Jin Z, Fisher J.

J Biomech. 2012 Jan 10;45(2):390-3. doi: 10.1016/j.jbiomech.2011.10.033.

PMID:
22119582
12.

Edge loading in metal-on-metal hips: low clearance is a new risk factor.

Underwood RJ, Zografos A, Sayles RS, Hart A, Cann P.

Proc Inst Mech Eng H. 2012 Mar;226(3):217-26.

13.

Influence of acetabular cup rim design on the contact stress during edge loading in ceramic-on-ceramic hip prostheses.

Mak M, Jin Z, Fisher J, Stewart TD.

J Arthroplasty. 2011 Jan;26(1):131-6. doi: 10.1016/j.arth.2009.10.019.

PMID:
20149581
14.

A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.

Kang L, Galvin AL, Jin ZM, Fisher J.

Proc Inst Mech Eng H. 2006 Jan;220(1):33-46.

PMID:
16459444
15.

Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge-loading conditions.

Al-Hajjar M, Fisher J, Williams S, Tipper JL, Jennings LM.

J Biomed Mater Res B Appl Biomater. 2013 Feb;101(2):213-22. doi: 10.1002/jbm.b.32824.

16.

Measuring functional outcome after total hip replacement with subject-specific hip joint loading.

Weber T, Dendorfer S, Dullien S, Grifka J, Verkerke GJ, Renkawitz T.

Proc Inst Mech Eng H. 2012 Dec;226(12):939-46. doi: 10.1177/0954411912447728.

PMID:
23636957
17.

The effect of under-reaming on the cup/bone interface of a press fit hip replacement.

Zivkovic I, Gonzalez M, Amirouche F.

J Biomech Eng. 2010 Apr;132(4):041008. doi: 10.1115/1.2913228.

PMID:
20387971
18.

The effect of cup orientation and coverage on contact mechanics and range of motion of metal-on-metal hip resurfacing arthroplasty.

Wang L, Williams S, Udofia I, Isaac G, Fisher J, Jin Z.

Proc Inst Mech Eng H. 2012 Nov;226(11):877-86.

PMID:
23185958
19.

Effect of simplifications of bone and components inclination on the elastohydrodynamic lubrication modeling of metal-on-metal hip resurfacing prosthesis.

Meng Q, Liu F, Fisher J, Jin Z.

Proc Inst Mech Eng H. 2013 May;227(5):523-34. doi: 10.1177/0954411912472845.

PMID:
23637262
20.

Analysis of contact mechanics in McKee-farrar metal-on-metal hip implants.

Yew A, Jagatia M, Ensaff H, Jin ZM.

Proc Inst Mech Eng H. 2003;217(5):333-40.

PMID:
14558645
Items per page

Supplemental Content

Support Center