Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 137

1.

Compact pulse width modulation circuitry for silicon photomultiplier readout.

Bieniosek MF, Olcott PD, Levin CS.

Phys Med Biol. 2013 Aug 7;58(15):5049-59. doi: 10.1088/0031-9155/58/15/5049. Epub 2013 Jul 8.

2.

Development of a prototype PET scanner with depth-of-interaction measurement using solid-state photomultiplier arrays and parallel readout electronics.

Shao Y, Sun X, Lan KA, Bircher C, Lou K, Deng Z.

Phys Med Biol. 2014 Mar 7;59(5):1223-38. doi: 10.1088/0031-9155/59/5/1223. Epub 2014 Feb 20.

3.

Achieving fast timing performance with multiplexed SiPMs.

Bieniosek MF, Cates JW, Levin CS.

Phys Med Biol. 2016 Apr 7;61(7):2879-92. doi: 10.1088/0031-9155/61/7/2879. Epub 2016 Mar 17.

PMID:
26987898
4.

Sensitivity encoded silicon photomultiplier--a new sensor for high-resolution PET-MRI.

Schulz V, Berker Y, Berneking A, Omidvari N, Kiessling F, Gola A, Piemonte C.

Phys Med Biol. 2013 Jul 21;58(14):4733-48. doi: 10.1088/0031-9155/58/14/4733. Epub 2013 Jun 20.

PMID:
23782507
5.

Optical delay encoding for fast timing and detector signal multiplexing in PET.

Grant AM, Levin CS.

Med Phys. 2015 Aug;42(8):4526-35. doi: 10.1118/1.4923176.

6.

Delay grid multiplexing: simple time-based multiplexing and readout method for silicon photomultipliers.

Won JY, Ko GB, Lee JS.

Phys Med Biol. 2016 Oct 7;61(19):7113-7135. Epub 2016 Sep 20.

PMID:
27648783
7.

Evaluation of Matrix9 silicon photomultiplier array for small-animal PET.

Du J, Schmall JP, Yang Y, Di K, Roncali E, Mitchell GS, Buckley S, Jackson C, Cherry SR.

Med Phys. 2015 Feb;42(2):585. doi: 10.1118/1.4905088.

8.

Optimizing timing performance of silicon photomultiplier-based scintillation detectors.

Yeom JY, Vinke R, Levin CS.

Phys Med Biol. 2013 Feb 21;58(4):1207-20. doi: 10.1088/0031-9155/58/4/1207. Epub 2013 Jan 31.

9.

Highly-Integrated CMOS Interface Circuits for SiPM-Based PET Imaging Systems.

Dey S, Lewellen TK, Miyaoka RS, Rudell JC.

IEEE Nucl Sci Symp Conf Rec (1997). 2012:3556-3559.

10.

A Simple Capacitive Charge-Division Readout for Position-Sensitive Solid-State Photomultiplier Arrays.

Du J, Schmall JP, Yang Y, Di K, Dokhale PA, Shah KS, Cherry SR.

IEEE Trans Nucl Sci. 2013 Oct;60(5):3188-3197.

11.

Depth-of-interaction measurement in a single-layer crystal array with a single-ended readout using digital silicon photomultiplier.

Lee MS, Lee JS.

Phys Med Biol. 2015 Aug 21;60(16):6495-514. doi: 10.1088/0031-9155/60/16/6495. Epub 2015 Aug 6.

PMID:
26247294
12.

Hybrid charge division multiplexing method for silicon photomultiplier based PET detectors.

Park H, Ko GB, Lee JS.

Phys Med Biol. 2017 Apr 3. doi: 10.1088/1361-6560/aa6aea. [Epub ahead of print]

PMID:
28368851
13.

A PET detector prototype based on digital SiPMs and GAGG scintillators.

Schneider FR, Shimazoe K, Somlai-Schweiger I, Ziegler SI.

Phys Med Biol. 2015 Feb 21;60(4):1667-79. doi: 10.1088/0031-9155/60/4/1667. Epub 2015 Jan 29.

PMID:
25633017
14.

Single transmission-line readout method for silicon photomultiplier based time-of-flight and depth-of-interaction PET.

Ko GB, Lee JS.

Phys Med Biol. 2017 Mar 21;62(6):2194-2207. doi: 10.1088/1361-6560/aa5a44. Epub 2017 Jan 18.

PMID:
28099158
15.

Highly multiplexed signal readout for a time-of-flight positron emission tomography detector based on silicon photomultipliers.

Cates JW, Bieniosek MF, Levin CS.

J Med Imaging (Bellingham). 2017 Jan;4(1):011012. doi: 10.1117/1.JMI.4.1.011012. Epub 2017 Mar 23.

PMID:
28382312
16.

A novel depth-of-interaction block detector for positron emission tomography using a dichotomous orthogonal symmetry decoding concept.

Zhang Y, Yan H, Baghaei H, Wong WH.

Phys Med Biol. 2016 Feb 21;61(4):1608-33. doi: 10.1088/0031-9155/61/4/1608. Epub 2016 Feb 2.

PMID:
26836144
17.

A Study of Position-Sensitive Solid-State Photomultiplier Signal Properties.

Schmall JP, Du J, Judenhofer MS, Dokhale P, Christian J, McClish M, Shah KS, Cherry SR.

IEEE Trans Nucl Sci. 2014 Jun 12;61(3):1074-1083.

18.

Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.

Yeom JY, Vinke R, Levin CS.

Med Phys. 2014 Dec;41(12):122501. doi: 10.1118/1.4901524.

19.

Energy and Timing Measurement with Time-Based Detector Readout for PET Applications: Principle and Validation with Discrete Circuit Components.

Sun X, Lan AK, Bircher C, Deng Z, Liu Y, Shao Y.

Nucl Instrum Methods Phys Res A. 2011 Jun 11;641(1):128-135.

20.

Development of brain PET using GAPD arrays.

Jung JH, Choi Y, Hong KJ, Kang J, Hu W, Lim HK, Huh Y, Kim S, Jung J, Kim KB.

Med Phys. 2012 Mar;39(3):1227-33. doi: 10.1118/1.3681012.

PMID:
22380353

Supplemental Content

Support Center