Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 72

1.
2.

The RABiT: a rapid automated biodosimetry tool for radiological triage. II. Technological developments.

Garty G, Chen Y, Turner HC, Zhang J, Lyulko OV, Bertucci A, Xu Y, Wang H, Simaan N, Randers-Pehrson G, Lawrence Yao Y, Brenner DJ.

Int J Radiat Biol. 2011 Aug;87(8):776-90. doi: 10.3109/09553002.2011.573612. Epub 2011 May 11.

3.

The RABIT: a rapid automated biodosimetry tool for radiological triage.

Garty G, Chen Y, Salerno A, Turner H, Zhang J, Lyulko O, Bertucci A, Xu Y, Wang H, Simaan N, Randers-Pehrson G, Yao YL, Amundson SA, Brenner DJ.

Health Phys. 2010 Feb;98(2):209-17. doi: 10.1097/HP.0b013e3181ab3cb6.

4.

DESIGN AND PRELIMINARY VALIDATION OF A RAPID AUTOMATED BIODOSIMETRY TOOL FOR HIGH THROUGPUT RADIOLOGICAL TRIAGE.

Chen Y, Zhang J, Wang H, Garty G, Xu Y, Lyulko OV, Turner HC, Randers-Pehrson G, Simaan N, Yao YL, Brenner DJ.

Proc ASME Des Eng Tech Conf. 2009 Jan 1;3:61-67.

5.

Validating high-throughput micronucleus analysis of peripheral reticulocytes for radiation biodosimetry: benchmark against dicentric and CBMN assays in a mouse model.

Chen Y, Tsai Y, Nowak I, Wang N, Hyrien O, Wilkins R, Ferrarotto C, Sun H, Dertinger SD.

Health Phys. 2010 Feb;98(2):218-27. doi: 10.1097/HP.0b013e3181abaae5.

PMID:
20065686
6.

Validation of the Cytokinesis-block Micronucleus Assay Using Imaging Flow Cytometry for High Throughput Radiation Biodosimetry.

Rodrigues MA, Beaton-Green LA, Wilkins RC.

Health Phys. 2016 Jan;110(1):29-36. doi: 10.1097/HP.0000000000000371.

PMID:
26606062
7.

Use of a centrifuge-based automated blood cell counter for radiation dose assessment.

Grace MB, Muderhwa JM, Salter CA, Blakely WF.

Mil Med. 2006 Sep;171(9):908-12.

PMID:
17036617
8.

Lactate accumulation in response to supramaximal exercise in rowers.

Maciejewski H, Bourdin M, Lacour JR, Denis C, Moyen B, Messonnier L.

Scand J Med Sci Sports. 2013 Oct;23(5):585-92. doi: 10.1111/j.1600-0838.2011.01423.x. Epub 2012 Jan 31.

PMID:
22288604
9.

Fast image analysis for the micronucleus assay in a fully automated high-throughput biodosimetry system.

Lyulko OV, Garty G, Randers-Pehrson G, Turner HC, Szolc B, Brenner DJ.

Radiat Res. 2014 Feb;181(2):146-61. doi: 10.1667/RR13441.1. Epub 2014 Feb 6.

10.

Infrastructure to support ultra high throughput biodosimetry screening after a radiological event.

Garty G, Karam A, Brenner DJ.

Int J Radiat Biol. 2011 Aug;87(8):754-65. doi: 10.3109/09553002.2011.583317. Epub 2011 Jun 15.

11.

Manual versus automated γ-H2AX foci analysis across five European laboratories: can this assay be used for rapid biodosimetry in a large scale radiation accident?

Rothkamm K, Barnard S, Ainsbury EA, Al-Hafidh J, Barquinero JF, Lindholm C, Moquet J, Perälä M, Roch-Lefèvre S, Scherthan H, Thierens H, Vral A, Vandersickel V.

Mutat Res. 2013 Aug 30;756(1-2):170-3. doi: 10.1016/j.mrgentox.2013.04.012. Epub 2013 May 3.

PMID:
23648320
12.

Radiation Dose Estimation by Automated Cytogenetic Biodosimetry.

Rogan PK, Li Y, Wilkins RC, Flegal FN, Knoll JH.

Radiat Prot Dosimetry. 2016 Dec;172(1-3):207-217. doi: 10.1093/rpd/ncw161. Epub 2016 Jul 13.

PMID:
27412514
13.

Rapid automated cell quantification on HIV microfluidic devices.

Alyassin MA, Moon S, Keles HO, Manzur F, Lin RL, Hæggstrom E, Kuritzkes DR, Demirci U.

Lab Chip. 2009 Dec 7;9(23):3364-9. doi: 10.1039/b911882a. Epub 2009 Sep 30.

14.

Analysis of chromosome damage for biodosimetry using imaging flow cytometry.

Beaton LA, Ferrarotto C, Kutzner BC, McNamee JP, Bellier PV, Wilkins RC.

Mutat Res. 2013 Aug 30;756(1-2):192-5. doi: 10.1016/j.mrgentox.2013.04.002. Epub 2013 Apr 22.

PMID:
23618924
15.

Application and Quantitative Validation of Computer-Automated Three-Dimensional Counting of Cell Nuclei.

Shain W, Kayali S, Szarowski D, Davis-Cox M, Ancin H, Bhattacharjya AK, Roysam B, Turner JN.

Microsc Microanal. 1999 Mar;5(2):106-119.

PMID:
10341010
16.
17.

Examining Radiation-Induced In Vivo and In Vitro Gene Expression Changes of the Peripheral Blood in Different Laboratories for Biodosimetry Purposes: First RENEB Gene Expression Study.

Abend M, Badie C, Quintens R, Kriehuber R, Manning G, Macaeva E, Njima M, Oskamp D, Strunz S, Moertl S, Doucha-Senf S, Dahlke S, Menzel J, Port M.

Radiat Res. 2016 Feb;185(2):109-23. doi: 10.1667/RR14221.1. Epub 2016 Feb 1.

PMID:
26829612
18.

A comparison of Makler counting chamber and improved Neubauer hemocytometer in sperm concentration measurement.

Sukcharoen N, Ngeamjirawat J, Chanprasit Y, Aribarg A.

J Med Assoc Thai. 1994 Sep;77(9):471-6.

PMID:
7706966
19.

Multi-parameter dose estimations in radiation biodosimetry using the automated cytokinesis-block micronucleus assay with imaging flow cytometry.

Rodrigues MA, Beaton-Green LA, Kutzner BC, Wilkins RC.

Cytometry A. 2014 Oct;85(10):883-93. doi: 10.1002/cyto.a.22511. Epub 2014 Aug 25.

20.

Flow cytometric validation of automated differentials in pediatric patients.

Finn LS, Hall J, Xu M, Rutledge JC.

Lab Hematol. 2004;10(2):112-8.

PMID:
15224768

Supplemental Content

Support Center