Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 106

1.

Evaluation of poly(lactic-co-glycolic acid) plate and screw system for bone fixation.

Park S, Kim JH, Kim IH, Lee M, Heo S, Kim H, Kim EH, Choy YB, Heo CY.

J Craniofac Surg. 2013 May;24(3):1021-5. doi: 10.1097/SCS.0b013e31827fee09.

PMID:
23714938
2.

A prospective trial of poly-L-lactic/polyglycolic acid co-polymer plates and screws for internal fixation of mandibular fractures.

Ferretti C.

Int J Oral Maxillofac Surg. 2008 Mar;37(3):242-8. doi: 10.1016/j.ijom.2007.11.015. Epub 2008 Mar 4.

PMID:
18295449
3.

Use of bioresorbable plating systems in paediatric mandible fractures.

Stanton DC, Liu F, Yu JW, Mistretta MC.

J Craniomaxillofac Surg. 2014 Oct;42(7):1305-9. doi: 10.1016/j.jcms.2014.03.015. Epub 2014 Apr 4.

PMID:
24815762
4.

Zygomaticomaxillary fracture repair with resorbable plates and screws.

Eppley BL.

J Craniofac Surg. 2000 Jul;11(4):377-85.

PMID:
11314387
5.

The efficacy of bioresorbable fixation in the repair of mandibular fractures: an animal study.

Quereshy FA, Goldstein JA, Goldberg JS, Beg Z.

J Oral Maxillofac Surg. 2000 Nov;58(11):1263-9.

PMID:
11078138
6.

Rigid internal fixation with titanium versus bioresorbable miniplates in the repair of mandibular fractures in rabbits.

Hochuli-Vieira E, Cabrini Gabrielli MA, Pereira-Filho VA, Gabrielli MF, Padilha JG.

Int J Oral Maxillofac Surg. 2005 Mar;34(2):167-73.

PMID:
15695046
7.

Biomechanical and histological evaluation of the application of biodegradable poly-L-lactic cushion to the plate internal fixation for bone fracture healing.

Fan Y, Xiu K, Duan H, Zhang M.

Clin Biomech (Bristol, Avon). 2008;23 Suppl 1:S7-S16. doi: 10.1016/j.clinbiomech.2008.01.005. Epub 2008 Mar 4.

PMID:
18291564
8.

Histologic and Histometric Analysis of Bone Repair at the Site of Mandibular Body Osteotomy and at the Bone-Screw Interface After Using a Biodegradable 2.0-mm Internal Fixation System.

Sverzut CE, de Matos FP, Trivellato AE, Kato RB, Sverzut AT, Taba Junior M, de Rezende Duek EA, de Oliveira PT.

J Craniofac Surg. 2015 Jun;26(4):1214-9. doi: 10.1097/SCS.0000000000001723.

PMID:
26080160
9.

Bioabsorbable plates and screws fixation in mandible fractures: clinical retrospective research during a 10-year period.

Rha EY, Paik H, Byeon JH.

Ann Plast Surg. 2015 Apr;74(4):432-6. doi: 10.1097/SAP.0b013e3182a60693.

PMID:
25551864
10.

Tissue restoration after resorption of polyglycolide and poly-laevo-lactic acid screws.

Böstman OM, Laitinen OM, Tynninen O, Salminen ST, Pihlajamäki HK.

J Bone Joint Surg Br. 2005 Nov;87(11):1575-80.

11.

Fixation of mandibular fractures with biodegradable plates and screws.

Yerit KC, Enislidis G, Schopper C, Turhani D, Wanschitz F, Wagner A, Watzinger F, Ewers R.

Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002 Sep;94(3):294-300.

PMID:
12324781
12.

Nonmetallic fixation in traumatic midfacial fractures.

Eppley BL, Prevel CD.

J Craniofac Surg. 1997 Mar;8(2):103-9.

PMID:
10332276
13.

Fixation of osteotomies using bioabsorbable screws in the canine femur.

An YH, Friedman RJ, Powers DL, Draughn RA, Latour RA Jr.

Clin Orthop Relat Res. 1998 Oct;(355):300-11.

PMID:
9917616
14.

Use of a resorbable fixation technique for maxillary fractures.

Eppley BL.

J Craniofac Surg. 1998 Jul;9(4):317-21.

PMID:
9780925
15.

Bioabsorbable plates and screws in pediatric craniofacial surgery: a review of 22 cases.

Kumar AV, Staffenberg DA, Petronio JA, Wood RJ.

J Craniofac Surg. 1997 Mar;8(2):97-9.

PMID:
10332274
16.

Functional load of plates in fracture fixation in vivo and its correlate in bone healing.

Stoffel K, Klaue K, Perren SM.

Injury. 2000 May;31 Suppl 2:S-B37-50.

PMID:
10853760
17.

Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients.

Eppley BL, Morales L, Wood R, Pensler J, Goldstein J, Havlik RJ, Habal M, Losken A, Williams JK, Burstein F, Rozzelle AA, Sadove AM.

Plast Reconstr Surg. 2004 Sep 15;114(4):850-6; discussion 857.

PMID:
15468389
18.

Biodegradable internal fixation plates enabled with X-ray visibility by a radiopaque layer of β-tricalcium phosphate and poly (lactic-co-glycolic acid).

Shasteen C, Park KY, Kwong SM, Jung SY, Lee SH, Park CG, Kim MH, Kim S, Son WC, Choi TH, Choy YB.

J Biomed Mater Res B Appl Biomater. 2013 Feb;101(2):320-9. doi: 10.1002/jbm.b.32842. Epub 2012 Nov 16. Erratum in: J Biomed Mater Res B Appl Biomater. 2014 Oct;102(7):1603.

PMID:
23165646
19.

Indications and limitations in resorbable P(L70/30DL)LA osteosyntheses of displaced mandibular fractures in 4.5-year follow-up.

Landes CA, Ballon A.

Plast Reconstr Surg. 2006 Feb;117(2):577-87; discussion 588-9.

PMID:
16462342
20.

Fixation of bimaxillary osteotomies with resorbable plates and screws: experience in 20 consecutive cases.

Edwards RC, Kiely KD, Eppley BL.

J Oral Maxillofac Surg. 2001 Mar;59(3):271-6.

PMID:
11243608

Supplemental Content

Support Center