Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 78

1.

Four-dimensional real-time cine images of wrist joint kinematics using dual source CT with minimal time increment scanning.

Choi YS, Lee YH, Kim S, Cho HW, Song HT, Suh JS.

Yonsei Med J. 2013 Jul;54(4):1026-32. doi: 10.3349/ymj.2013.54.4.1026.

2.

Dynamic CT technique for assessment of wrist joint instabilities.

Leng S, Zhao K, Qu M, An KN, Berger R, McCollough CH.

Med Phys. 2011 Jul;38 Suppl 1:S50. doi: 10.1118/1.3577759.

3.

Four-dimensional computed tomographic imaging in the wrist: proof of feasibility in a cadaveric model.

Tay SC, Primak AN, Fletcher JG, Schmidt B, Amrami KK, Berger RA, McCollough CH.

Skeletal Radiol. 2007 Dec;36(12):1163-9. Epub 2007 Sep 6.

PMID:
17805530
5.

Development and validation of a computed tomography-based methodology to measure carpal kinematics.

Pfaeffle J, Blankenhorn B, Stabile K, Imbriglia J, Goitz R, Robertson D.

J Biomech Eng. 2005 Jun;127(3):541-8.

PMID:
16060362
6.

A method for carpal motion hysteresis quantification in 4-dimensional imaging of the wrist.

Mat Jais IS, Liu X, An KN, Tay SC.

Med Eng Phys. 2014 Dec;36(12):1699-703. doi: 10.1016/j.medengphy.2014.08.011. Epub 2014 Sep 30.

PMID:
25277831
7.

In vivo length changes of selected carpal ligaments during wrist radioulnar deviation.

Xu J, Tang JB.

J Hand Surg Am. 2009 Mar;34(3):401-8. doi: 10.1016/j.jhsa.2008.11.013.

PMID:
19258136
8.

Wide field of view computed tomography and mid-carpal instability: the value of the sagittal radius-lunate-capitate axis--preliminary experience.

Repse SE, Koulouris G, Troupis JM.

Eur J Radiol. 2015 May;84(5):908-14. doi: 10.1016/j.ejrad.2015.01.020. Epub 2015 Feb 9.

PMID:
25708808
9.

In vivo kinematic study of normal wrist motion: an ultrafast computed tomographic study.

Sun JS, Shih TT, Ko CM, Chang CH, Hang YS, Hou SM.

Clin Biomech (Bristol, Avon). 2000 Mar;15(3):212-6.

PMID:
10656983
10.

[Three-dimensional CT study of the carpus under pronation-supination constraints].

Kapandji AI, Martin-Bouyer Y, Verdeille S.

Ann Chir Main Memb Super. 1991;10(1):36-47. French.

PMID:
1712612
11.

4D rotational x-ray imaging of wrist joint dynamic motion.

Carelsen B, Bakker NH, Strackee SD, Boon SN, Maas M, Sabczynski J, Grimbergen CA, Streekstra GJ.

Med Phys. 2005 Sep;32(9):2771-6.

PMID:
16266090
12.

The effect of lunate morphology on the 3-dimensional kinematics of the carpus.

Bain GI, Clitherow HD, Millar S, Fraysse F, Costi JJ, Eng K, McGuire DT, Thewlis D.

J Hand Surg Am. 2015 Jan;40(1):81-9.e1. doi: 10.1016/j.jhsa.2014.09.019. Epub 2014 Oct 23.

PMID:
25447001
13.

Kinematics of the wrist using 2D and 3D analysis: biomechanical and clinical deductions.

Camus EJ, Millot F, Lariviere J, Raoult S, Rtaimate M.

Surg Radiol Anat. 2004 Oct;26(5):399-410.

PMID:
15290105
14.

In-vivo three-dimensional carpal bone kinematics during flexion-extension and radio-ulnar deviation of the wrist: Dynamic motion versus step-wise static wrist positions.

Foumani M, Strackee SD, Jonges R, Blankevoort L, Zwinderman AH, Carelsen B, Streekstra GJ.

J Biomech. 2009 Dec 11;42(16):2664-71. doi: 10.1016/j.jbiomech.2009.08.016. Epub 2009 Sep 12.

PMID:
19748626
15.

In vivo gliding and contact characteristics of the sigmoid notch and the ulna in forearm rotation.

Chen YR, Tang JB.

J Hand Surg Am. 2013 Aug;38(8):1513-9. doi: 10.1016/j.jhsa.2013.04.023. Epub 2013 Jun 21.

PMID:
23796715
16.

Noninvasive technique for measuring in vivo three-dimensional carpal bone kinematics.

Crisco JJ, McGovern RD, Wolfe SW.

J Orthop Res. 1999 Jan;17(1):96-100.

PMID:
10073653
17.

In vivo changes in lengths of the ligaments stabilizing the distal radioulnar joint.

Xu J, Tang JB.

J Hand Surg Am. 2009 Jan;34(1):40-5. doi: 10.1016/j.jhsa.2008.08.006. Epub 2008 Dec 5.

PMID:
19058922
19.

The triquetrum-hamate joint: an anatomic and in vivo three-dimensional kinematic study.

Moritomo H, Goto A, Sato Y, Sugamoto K, Murase T, Yoshikawa H.

J Hand Surg Am. 2003 Sep;28(5):797-805.

PMID:
14507511
20.

Pisiform kinematics in vivo.

Moojen TM, Snel JG, Ritt MJ, Venema HW, den Heeten GJ, Bos KE.

J Hand Surg Am. 2001 Sep;26(5):901-7.

PMID:
11561244

Supplemental Content

Support Center