Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 440

1.

Application of protective stents in endovascular repair of acute complicated Stanford type B aortic dissections.

Liu JF, Jiang WL, Lu HT, Li YL, Zhang TH, Yamakawa T.

J Endovasc Ther. 2013 Apr;20(2):210-8. doi: 10.1583/1545-1550-20.2.210.

PMID:
23581765
2.

Volume analysis of true and false lumens in acute complicated type B aortic dissections after thoracic endovascular aortic repair with stent grafts alone or with a composite device design.

Sobocinski J, Lombardi JV, Dias NV, Berger L, Zhou Q, Jia F, Resch T, Haulon S.

J Vasc Surg. 2016 May;63(5):1216-24. doi: 10.1016/j.jvs.2015.11.037. Epub 2016 Jan 22.

PMID:
26806523
3.

Endovascular repair of Stanford B aortic dissection using two stent grafts with different sizes.

Huang X, Huang L, Sun L, Xu S, Xue Y, Zeng Q, Guo X, Peng M.

J Vasc Surg. 2015 Jul;62(1):43-8. doi: 10.1016/j.jvs.2015.02.022.

4.

Restrictive bare stent for prevention of stent graft-induced distal redissection after thoracic endovascular aortic repair for type B aortic dissection.

Feng J, Lu Q, Zhao Z, Bao J, Feng X, Qu L, Zhou J, Jing Z.

J Vasc Surg. 2013 Feb;57(2 Suppl):44S-52S. doi: 10.1016/j.jvs.2012.06.117.

5.

Prospective multicenter clinical trial (STABLE) on the endovascular treatment of complicated type B aortic dissection using a composite device design.

Lombardi JV, Cambria RP, Nienaber CA, Chiesa R, Teebken O, Lee A, Mossop P, Bharadwaj P; STABLE investigators.

J Vasc Surg. 2012 Mar;55(3):629-640.e2. doi: 10.1016/j.jvs.2011.10.022. Epub 2011 Dec 9.

6.

Modified Petticoat Technique with Pre-placement of a Distal Bare Stent Improves Early Aortic Remodeling after Complicated Acute Stanford Type B Aortic Dissection.

He H, Yao K, Nie WP, Wang Z, Liang Q, Shu C, Dardik A.

Eur J Vasc Endovasc Surg. 2015 Oct;50(4):450-9. doi: 10.1016/j.ejvs.2015.04.035. Epub 2015 Jun 19.

7.

A morphologic study of chronic type B aortic dissections and aneurysms after thoracic endovascular stent grafting.

Qing KX, Yiu WK, Cheng SW.

J Vasc Surg. 2012 May;55(5):1268-75; discussion 1275-6. doi: 10.1016/j.jvs.2011.11.099. Epub 2012 Jan 17.

8.

Aortic remodeling after endovascular repair with stainless steel-based stent graft in acute and chronic type B aortic dissection.

Yang CP, Hsu CP, Chen WY, Chen IM, Weng CF, Chen CK, Shih CC.

J Vasc Surg. 2012 Jun;55(6):1600-10. doi: 10.1016/j.jvs.2011.12.008. Epub 2012 Mar 28.

9.

Early results of left carotid chimney technique in endovascular repair of acute non-a-non-B aortic dissections.

Shu C, Luo MY, Li QM, Li M, Wang T, He H.

J Endovasc Ther. 2011 Aug;18(4):477-84. doi: 10.1583/11-3401.1.

PMID:
21861733
10.

Factors predictive of distal stent graft-induced new entry after hybrid arch elephant trunk repair with stainless steel-based device in aortic dissection.

Huang CY, Weng SH, Weng CF, Chen WY, Chen IM, Hsu CP, Shih CC.

J Thorac Cardiovasc Surg. 2013 Sep;146(3):623-30. doi: 10.1016/j.jtcvs.2012.07.052. Epub 2012 Oct 4.

11.

Fenestrated and branched endovascular aortic repair for chronic type B aortic dissection with thoracoabdominal aneurysms.

Kitagawa A, Greenberg RK, Eagleton MJ, Mastracci TM, Roselli EE.

J Vasc Surg. 2013 Sep;58(3):625-34. doi: 10.1016/j.jvs.2013.01.049. Epub 2013 Jun 22.

12.

Emergency endovascular stent-grafting for acute type B aortic dissection with symptomatic malperfusion.

Shu C, Fang K, Luo M, Li Q, Wang Z.

Int Angiol. 2013 Oct;32(5):483-91.

PMID:
23903307
13.

Thoracic aortic aneurysm expansion due to late distal stent graft-induced new entry.

Jánosi RA, Tsagakis K, Bettin M, Kahlert P, Horacek M, Al-Rashid F, Schlosser T, Jakob H, Eggebrecht H, Erbel R.

Catheter Cardiovasc Interv. 2015 Feb 1;85(2):E43-53. doi: 10.1002/ccd.25614. Epub 2014 Aug 5.

PMID:
25044741
14.

Risk factors for stent graft-induced new entry after thoracic endovascular aortic repair for Stanford type B aortic dissection.

Jang H, Kim MD, Kim GM, Won JY, Ko YG, Choi D, Joo HC, Lee DY.

J Vasc Surg. 2017 Mar;65(3):676-685. doi: 10.1016/j.jvs.2016.09.022.

PMID:
28236916
15.

Volumetric analysis of type B aortic dissections treated with thoracic endovascular aortic repair.

Stanley GA, Murphy EH, Knowles M, Ilves M, Jessen ME, Dimaio JM, Modrall JG, Arko FR 3rd.

J Vasc Surg. 2011 Oct;54(4):985-92; discussion 992. doi: 10.1016/j.jvs.2011.03.263. Epub 2011 Sep 13.

16.

Thoracic Endovascular Aortic Repair Combined with Assistant Techniques and Devices for the Treatment of Acute Complicated Stanford Type B Aortic Dissections Involving Aortic Arch.

Zhang T, Jiang W, Lu H, Liu J.

Ann Vasc Surg. 2016 Apr;32:88-97. doi: 10.1016/j.avsg.2015.10.030. Epub 2016 Jan 22.

PMID:
26806251
17.

The single-centre experience of the supra-arch chimney technique in endovascular repair of type B aortic dissections.

Zhu Y, Guo W, Liu X, Jia X, Xiong J, Wang L.

Eur J Vasc Endovasc Surg. 2013 Jun;45(6):633-8. doi: 10.1016/j.ejvs.2013.02.016. Epub 2013 Mar 27.

18.

Association between Aortic Remodeling and Stent Graft-Induced New Entry in Extensive Residual Type A Dissecting Aortic Aneurysm after Hybrid Arch Repair.

Huang CY, Chen CW, Chen PL, Chen WY, Chen IM, Hsu CP, Shih CC.

Ann Vasc Surg. 2016 Feb;31:60-9. doi: 10.1016/j.avsg.2015.08.022. Epub 2015 Dec 2.

PMID:
26620378
19.

Reintervention after thoracic endovascular aortic repair of complicated aortic dissection.

Faure EM, Canaud L, Agostini C, Shaub R, Böge G, Marty-ané C, Alric P.

J Vasc Surg. 2014 Feb;59(2):327-33. doi: 10.1016/j.jvs.2013.08.089. Epub 2013 Oct 15.

20.

Midterm results with thoracic endovascular aortic repair for chronic type B aortic dissection with associated aneurysm.

Parsa CJ, Williams JB, Bhattacharya SD, Wolfe WG, Daneshmand MA, McCann RL, Hughes GC.

J Thorac Cardiovasc Surg. 2011 Feb;141(2):322-7. doi: 10.1016/j.jtcvs.2010.10.043.

Supplemental Content

Support Center