Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 126

1.

Comparison of left ventricular geometry after HeartMate II and HeartWare left ventricular assist device implantation.

Hosseini MT, Popov AF, Simon AR, Amrani M, Bahrami T.

J Cardiothorac Surg. 2013 Feb 28;8:31. doi: 10.1186/1749-8090-8-31.

2.

Design changes in continuous-flow left ventricular assist devices and life-threatening pump malfunctions.

Soltani S, Kaufmann F, Vierecke J, Kretzschmar A, Hennig E, Stein J, Hetzer R, Krabatsch T, Potapov EV.

Eur J Cardiothorac Surg. 2015 Jun;47(6):984-9. doi: 10.1093/ejcts/ezu347.

PMID:
25209626
3.

Comparative cost-effectiveness of the HeartWare versus HeartMate II left ventricular assist devices used in the United Kingdom National Health Service bridge-to-transplant program for patients with heart failure.

Pulikottil-Jacob R, Suri G, Connock M, Kandala NB, Sutcliffe P, Maheswaran H, Banner NR, Clarke A.

J Heart Lung Transplant. 2014 Apr;33(4):350-8. doi: 10.1016/j.healun.2014.01.003.

4.

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

Patel ND, Weiss ES, Schaffer J, Ullrich SL, Rivard DC, Shah AS, Russell SD, Conte JV.

Ann Thorac Surg. 2008 Sep;86(3):832-40; discussion 832-40. doi: 10.1016/j.athoracsur.2008.05.016.

PMID:
18721570
5.

Perioperative blood product use: a comparison between HeartWare and HeartMate II devices.

Haglund NA, Davis ME, Tricarico NM, Ahmad RM, DiSalvo TG, Keebler ME, Schlendorf KH, Wigger MA, Stulak JM, Maltais S.

Ann Thorac Surg. 2014 Sep;98(3):842-9. doi: 10.1016/j.athoracsur.2014.05.016.

PMID:
25085559
6.

Readmissions After Continuous Flow Left Ventricular Assist Device Implantation: Differences Observed Between Two Contemporary Device Types.

Haglund NA, Davis ME, Tricarico NM, Keebler ME, Maltais S.

ASAIO J. 2015 Jul-Aug;61(4):410-6. doi: 10.1097/MAT.0000000000000218.

PMID:
25806614
7.

Left ventricular reverse remodeling with a continuous flow left ventricular assist device measured by left ventricular end-diastolic dimensions and severity of mitral regurgitation.

Morgan JA, Brewer RJ, Nemeh HW, Murthy R, Williams CT, Lanfear DE, Tita C, Paone G.

ASAIO J. 2012 Nov-Dec;58(6):574-7. doi: 10.1097/MAT.0b013e31826e4267.

PMID:
23103696
8.

Results of the post-U.S. Food and Drug Administration-approval study with a continuous flow left ventricular assist device as a bridge to heart transplantation: a prospective study using the INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support).

Starling RC, Naka Y, Boyle AJ, Gonzalez-Stawinski G, John R, Jorde U, Russell SD, Conte JV, Aaronson KD, McGee EC Jr, Cotts WG, DeNofrio D, Pham DT, Farrar DJ, Pagani FD.

J Am Coll Cardiol. 2011 May 10;57(19):1890-8. doi: 10.1016/j.jacc.2010.10.062. Erratum in: J Am Coll Cardiol. 2011 Nov 8;58(20):2142.

9.
10.

End-stage heart failure: is there a role for the Batista procedure?

Frota Filho JD, Pereira WM, Leães PE, Blacher C, Jung LA, Lucchese F.

Heart Surg Forum. 1998;1(1):41-8.

PMID:
11276439
11.

Outcomes in patients receiving HeartMate II versus HVAD left ventricular assist device as a bridge to transplantation.

Sabashnikov A, Mohite PN, Zych B, Popov AF, Fatullayev J, Zeriouh M, Hards R, Sáez DG, Capoccia M, Choi YH, Wahlers T, De Robertis F, Bahrami T, Amrani M, Simon AR.

Transplant Proc. 2014 Jun;46(5):1469-75. doi: 10.1016/j.transproceed.2013.12.057.

PMID:
24935315
12.

Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy.

John R, Kamdar F, Liao K, Colvin-Adams M, Boyle A, Joyce L.

Ann Thorac Surg. 2008 Oct;86(4):1227-34; discussion 1234-5. doi: 10.1016/j.athoracsur.2008.06.030.

PMID:
18805167
13.

A case of late-onset right ventricular failure after implantation of a continuous-flow left ventricular assist device.

Imamura T, Kinugawa K, Shiga T, Endo M, Inaba T, Maki H, Hatano M, Yao A, Nishimura T, Hirata Y, Kyo S, Ono M, Nagai R.

J Artif Organs. 2012 Jun;15(2):200-3. doi: 10.1007/s10047-011-0627-z.

PMID:
22249901
14.

Ischemic versus nonischemic dilated cardiomyopathy: the implications of heart failure etiology on left ventricular assist device outcomes.

Tsiouris A, Borgi J, Karam J, Nemeh HW, Paone G, Brewer RJ, Morgan JA.

ASAIO J. 2013 Mar-Apr;59(2):130-5. doi: 10.1097/MAT.0b013e31828579af.

PMID:
23438774
15.

Variability in fibrosis in tissue samples obtained during diaphragmatic and apical LVAD implantation.

Segura AM, Radovancevic R, Aguayo A, Frazier OH, Buja LM.

Cardiovasc Pathol. 2014 May-Jun;23(3):121-5. doi: 10.1016/j.carpath.2013.12.002.

PMID:
24484611
16.

Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation.

Uriel N, Pak SW, Jorde UP, Jude B, Susen S, Vincentelli A, Ennezat PV, Cappleman S, Naka Y, Mancini D.

J Am Coll Cardiol. 2010 Oct 5;56(15):1207-13. doi: 10.1016/j.jacc.2010.05.016.

17.

Surgical technique influences HeartMate II left ventricular assist device thrombosis.

Taghavi S, Ward C, Jayarajan SN, Gaughan J, Wilson LM, Mangi AA.

Ann Thorac Surg. 2013 Oct;96(4):1259-65. doi: 10.1016/j.athoracsur.2013.05.081.

PMID:
23968757
18.

Who would be a candidate for bridge to recovery during prolonged mechanical left ventricular support in idiopathic dilated cardiomyopathy?

Matsumiya G, Monta O, Fukushima N, Sawa Y, Funatsu T, Toda K, Matsuda H.

J Thorac Cardiovasc Surg. 2005 Sep;130(3):699-704.

19.

Implantation of HeartMate II Left Ventricular Assist Device in a Single-Lung Patient.

Copeland H, Stoletniy L, Sakr A, Razzouk A.

Ann Thorac Surg. 2015 Jun;99(6):2216-8. doi: 10.1016/j.athoracsur.2014.08.053.

PMID:
26046884
20.

Minimally invasive, off-pump explant of a continuous-flow left ventricular assist device.

Cheung A, Bashir J, Kaan A, Kealy J, Moss R, Shayan H.

J Heart Lung Transplant. 2010 Jul;29(7):808-10. doi: 10.1016/j.healun.2010.01.006.

PMID:
20363154

Supplemental Content

Support Center