Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 203

1.

Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up.

Sakai T, Ohzono K, Nishii T, Takao M, Miki H, Nakamura N, Sugano N.

Int Orthop. 2013 Apr;37(4):605-10. doi: 10.1007/s00264-013-1818-4. Epub 2013 Feb 20.

2.

Use of porous tantalum components in Paprosky two and three acetabular revision. A minimum five-year follow-up of fifty one hips.

Flecher X, Appy B, Parratte S, Ollivier M, Argenson JN.

Int Orthop. 2017 May;41(5):911-916. doi: 10.1007/s00264-016-3312-2. Epub 2016 Oct 21.

PMID:
27766385
3.

[Acetabular revision for aseptic loosening in total hip arthroplasty using cementless cup and impacted morselized allograft].

Parratte S, Argenson JN, Flecher X, Aubaniac JM.

Rev Chir Orthop Reparatrice Appar Mot. 2007 May;93(3):255-63. French.

PMID:
17534208
4.

THA revisions using impaction allografting with mesh is durable for medial but not lateral acetabular defects.

García-Rey E, Madero R, García-Cimbrelo E.

Clin Orthop Relat Res. 2015 Dec;473(12):3882-91. doi: 10.1007/s11999-015-4483-7.

5.

[Oblong acetabular cup, type TC, for revision total hip arthroplasty].

Trč T, Stastný E.

Acta Chir Orthop Traumatol Cech. 2012;79(6):506-11. Czech.

PMID:
23286682
6.

[Hooked roof cup in revision of difficult loose hip prosthesis cups. Results after a minimum of 10 years].

Siebenrock KA, Trochsler M, Sadri H, Ganz R.

Orthopade. 2001 May;30(5):273-9. German.

PMID:
11417234
7.

Acetabular reconstruction with impaction bone-grafting and a cemented cup in patients younger than fifty years old.

Schreurs BW, Busch VJ, Welten ML, Verdonschot N, Slooff TJ, Gardeniers JW.

J Bone Joint Surg Am. 2004 Nov;86-A(11):2385-92.

PMID:
15523007
8.
9.

[Long-term results of the CLS acetabular cup in primary total hip replacement].

Rozkydal Z, Janícek P, Tomás T, Florian Z.

Acta Chir Orthop Traumatol Cech. 2009 Apr;76(2):90-7. Czech.

PMID:
19439127
10.

[Structural femoral head allografts in revision surgery of loosened acetabular cups].

Wedemeyer C, Otte S, von Knoch M, Quint U, von Knoch F, Löer F, Saxler G.

Unfallchirurg. 2007 Feb;110(2):104-10. German.

PMID:
17109174
11.

Porous-ingrowth revision acetabular implants secured with peripheral screws. A minimum twelve-year follow-up.

Weeden SH, Paprosky WG.

J Bone Joint Surg Am. 2006 Jun;88(6):1266-71.

PMID:
16757760
12.

Can cemented dual-mobility cups be used without a reinforcement device in cases of mild acetabular bone stock alteration in total hip arthroplasty?

Haen TX, Lonjon G, Vandenbussche E.

Orthop Traumatol Surg Res. 2015 Dec;101(8):923-7. doi: 10.1016/j.otsr.2015.09.027. Epub 2015 Nov 2.

13.

Radiological evaluation of allograft reconstruction in acetabulum with Ganz reinforcement ring in revision total hip replacement.

Uchiyama K, Takahira N, Fukushima K, Yamamoto T, Moriya M, Itoman M.

J Orthop Sci. 2010 Nov;15(6):764-71. doi: 10.1007/s00776-010-1549-y. Epub 2010 Nov 30.

PMID:
21116894
14.

Acetabular reconstruction with impacted morsellised cancellous bone graft and cement. A 10- to 15-year follow-up of 60 revision arthroplasties.

Schreurs BW, Slooff TJ, Buma P, Gardeniers JW, Huiskes R.

J Bone Joint Surg Br. 1998 May;80(3):391-5.

15.

[Revision of failed acetabular cups with extensive structural allografts].

Saxler G, Fitzek JG, Sterner T, von Knoch M, Barden B, Löer F.

Z Orthop Ihre Grenzgeb. 2005 Jan-Feb;143(1):56-63. German.

PMID:
15754233
16.

[Reconstruction of severe acetabular bone defects using Burch-Schneider cage].

Gallo J, Rozkydal Z, Sklenský M.

Acta Chir Orthop Traumatol Cech. 2006 Jun;73(3):157-63. Czech.

PMID:
16846560
17.

Uncemented jumbo cups for revision total hip arthroplasty: a concise follow-up, at a mean of twenty years, of a previous report.

von Roth P, Abdel MP, Harmsen WS, Berry DJ.

J Bone Joint Surg Am. 2015 Feb 18;97(4):284-7. doi: 10.2106/JBJS.N.00798.

PMID:
25695978
18.

Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty.

Nehme A, Lewallen DG, Hanssen AD.

Clin Orthop Relat Res. 2004 Dec;(429):201-8.

PMID:
15577488
19.

Acetabular revision surgery with the LOR cup: three to 8 years' follow-up.

Surace MF, Zatti G, De Pietri M, Cherubino P.

J Arthroplasty. 2006 Jan;21(1):114-21.

PMID:
16446195
20.

The Exeter Contemporary flanged cemented acetabular component in primary total hip arthroplasty.

Maggs JL, Smeatham A, Whitehouse SL, Charity J, Timperley AJ, Gie GA.

Bone Joint J. 2016 Mar;98-B(3):307-12. doi: 10.1302/0301-620X.98B3.35901.

PMID:
26920954

Supplemental Content

Support Center