Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 123

1.

Determination of vessel wall dynamics by optical microsensors.

Ruh D, Sherman S, Theodor M, Ruhhammer J, Foerster K, Heilmann C, Beyersdorf F, Zappe H, Seifert A.

Conf Proc IEEE Eng Med Biol Soc. 2012;2012:2359-62. doi: 10.1109/EMBC.2012.6346437.

PMID:
23366398
2.

Development of a novel pulse wave velocity measurement system: using dual piezoelectric elements.

Kitamura K, Takeuchi R, Ogai K, Xin Z, Chen W, Nemoto T.

Med Eng Phys. 2014 Jul;36(7):927-32. doi: 10.1016/j.medengphy.2014.02.024. Epub 2014 Mar 25.

PMID:
24674743
3.

Cantilever arrayed blood pressure sensor for arterial applanation tonometry.

Lee B, Jeong J, Kim J, Kim B, Chun K.

IET Nanobiotechnol. 2014 Mar;8(1):37-43.

PMID:
24888190
4.

Pulse transit time differential measurement by fiber Bragg grating pulse recorder.

Umesh S, Padma S, Ambastha S, Kalegowda A, Asokan S.

J Biomed Opt. 2015 May;20(5):57005. doi: 10.1117/1.JBO.20.5.057005.

PMID:
26021719
5.

Development of an implantable pulse oximeter.

Reichelt S, Fiala J, Werber A, Förster K, Heilmann C, Klemm R, Zappe H.

IEEE Trans Biomed Eng. 2008 Feb;55(2 Pt 1):581-8. doi: 10.1109/TBME.2007.902242.

PMID:
18269993
6.

Pseudo-random single photon counting for time-resolved optical measurement.

Zhang Q, Soon HW, Tian H, Fernando S, Ha Y, Chen NG.

Opt Express. 2008 Aug 18;16(17):13233-9.

PMID:
18711561
7.

On-chip interferometric detection of nanomechanical motion.

Unterreithmeier QP, Faust T, Manus S, Kotthaus JP.

Nano Lett. 2010 Mar 10;10(3):887-90. doi: 10.1021/nl903556s.

PMID:
20131919
8.

Arterial strain measurement by implantable capacitive sensor without vessel constriction.

Ruhhammer J, Ruh D, Foerster K, Heilmann C, Beyersdorf F, Barker A, Jung B, Seifert A, Goldschmidtboeing F, Woias P.

Conf Proc IEEE Eng Med Biol Soc. 2012;2012:535-8. doi: 10.1109/EMBC.2012.6345986.

PMID:
23365947
9.

Nonpulsatile and noninvasive transmittance and reflectance tissue-bed oximetry.

Kemeny A, Geddes LA.

Cardiovasc Eng. 2006 Dec;6(4):145-50.

PMID:
17109240
10.

An implantable optical blood pressure sensor based on pulse transit time.

Fiala J, Bingger P, Ruh D, Foerster K, Heilmann C, Beyersdorf F, Zappe H, Seifert A.

Biomed Microdevices. 2013 Feb;15(1):73-81. doi: 10.1007/s10544-012-9689-9.

PMID:
23053446
11.

Subcutaneous blood pressure monitoring with an implantable optical sensor.

Theodor M, Ruh D, Fiala J, Förster K, Heilmann C, Manoli Y, Beyersdorf F, Zappe H, Seifert A.

Biomed Microdevices. 2013 Oct;15(5):811-20. doi: 10.1007/s10544-013-9768-6.

PMID:
23657895
12.

Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Mukkamala R, Hahn JO, Inan OT, Mestha LK, Kim CS, Töreyin H, Kyal S.

IEEE Trans Biomed Eng. 2015 Aug;62(8):1879-901. doi: 10.1109/TBME.2015.2441951. Epub 2015 Jun 5.

13.

Scanning evanescent fields using a pointlike light source and a nanomechanical DNA gear.

Brutzer H, Schwarz FW, Seidel R.

Nano Lett. 2012 Jan 11;12(1):473-8. doi: 10.1021/nl203876w. Epub 2011 Dec 16.

PMID:
22148854
14.

In-plane all-photonic transduction with differential splitter using double-step rib waveguide for photonic microcantilever arrays.

Noh JW, Anderson RR, Kim S, Hu W, Nordin GP.

Opt Express. 2009 Oct 26;17(22):20012-20. doi: 10.1364/OE.17.020012.

PMID:
19997225
15.

Noninvasive measurement of instantaneous radial artery blood pressure. An instrument based on the volume-compensation method.

Tanaka S, Gao S, Nogawa M, Yamakoshi K.

IEEE Eng Med Biol Mag. 2005 Jul-Aug;24(4):32-7. No abstract available.

PMID:
16119210
16.
17.

Photonic textiles for pulse oximetry.

Rothmaier M, Selm B, Spichtig S, Haensse D, Wolf M.

Opt Express. 2008 Aug 18;16(17):12973-86.

PMID:
18711536
18.

A new noise reduction method for oscillometric blood pressure measurement.

Choi HS, Myoung HS, Lee HK, Park HD, Lee KJ.

Conf Proc IEEE Eng Med Biol Soc. 2008;2008:270-2. doi: 10.1109/IEMBS.2008.4649142.

PMID:
19162645
19.

Remote estimation of blood pulse pressure via temporal tracking of reflected secondary speckles pattern.

Beiderman Y, Horovitz I, Burshtein N, Teicher M, Garcia J, Mico V, Zalevsky Z.

J Biomed Opt. 2010 Nov-Dec;15(6):061707. doi: 10.1117/1.3505008.

PMID:
21198155
20.

A single source femtosecond-millisecond broadband spectrometer.

Carroll EC, Hill MP, Madsen D, Malley KR, Larsen DS.

Rev Sci Instrum. 2009 Feb;80(2):026102. doi: 10.1063/1.3070516.

PMID:
19256678

Supplemental Content

Support Center