Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 234

1.

Evaluation of rotator cuff tendon tears: comparison of multidetector CT arthrography and 1.5-T MR arthrography.

Omoumi P, Bafort AC, Dubuc JE, Malghem J, Vande Berg BC, Lecouvet FE.

Radiology. 2012 Sep;264(3):812-22. doi: 10.1148/radiol.12112062.

PMID:
22919041
2.

Tears of the supraspinatus tendon: assessment with indirect magnetic resonance arthrography in 67 patients with arthroscopic correlation.

Van Dyck P, Gielen JL, Veryser J, Weyler J, Vanhoenacker FM, Van Glabbeek F, De Weerdt W, Maas M, van der Woude HJ, Parizel PM.

Acta Radiol. 2009 Nov;50(9):1057-63. doi: 10.3109/02841850903232723.

PMID:
19863417
3.

Reproducibility and reliability of subscapularis tendon assessment using CT-arthrography.

Szymanski C, Staquet V, Deladerrière JY, Vervoort T, Audebert S, Maynou C.

Orthop Traumatol Surg Res. 2013 Feb;99(1):2-9. doi: 10.1016/j.otsr.2012.07.014. Epub 2012 Dec 12.

4.

Comparison of indirect isotropic MR arthrography and conventional MR arthrography of labral lesions and rotator cuff tears: a prospective study.

Oh DK, Yoon YC, Kwon JW, Choi SH, Jung JY, Bae S, Yoo J.

AJR Am J Roentgenol. 2009 Feb;192(2):473-9. doi: 10.2214/AJR.08.1223.

PMID:
19155413
5.

Indirect MR arthrography of the shoulder: use of abduction and external rotation to detect full- and partial-thickness tears of the supraspinatus tendon.

Herold T, Bachthaler M, Hamer OW, Hente R, Feuerbach S, Fellner C, Strotzer M, Lenhart M, Paetzel C.

Radiology. 2006 Jul;240(1):152-60. Epub 2006 May 18.

PMID:
16709790
6.

Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation.

Waldt S, Bruegel M, Mueller D, Holzapfel K, Imhoff AB, Rummeny EJ, Woertler K.

Eur Radiol. 2007 Feb;17(2):491-8. Epub 2006 Sep 13.

PMID:
16969638
7.

Rotator cuff tears noncontrast MRI compared to MR arthrography.

Lee JH, Yoon YC, Jung JY, Yoo JC.

Skeletal Radiol. 2015 Dec;44(12):1745-54. doi: 10.1007/s00256-015-2228-z. Epub 2015 Aug 11.

PMID:
26260536
8.

Supraspinatus tendon tears at 3.0 T shoulder MR arthrography: diagnosis with 3D isotropic turbo spin-echo SPACE sequence versus 2D conventional sequences.

Jung JY, Jee WH, Park MY, Lee SY, Kim YS.

Skeletal Radiol. 2012 Nov;41(11):1401-10. Epub 2012 Feb 10.

PMID:
22322904
9.

Diagnostic performance of indirect MR arthrography for the diagnosis of rotator cuff tears at 3.0 T.

Lee JH, Yoon YC, Jee S.

Acta Radiol. 2015 Jun;56(6):720-6. doi: 10.1177/0284185114537817. Epub 2014 Jun 17.

PMID:
24938663
10.

Detection of partial-thickness supraspinatus tendon tears: is a single direct MR arthrography series in ABER position as accurate as conventional MR arthrography?

Schreinemachers SA, van der Hulst VP, Willems WJ, Bipat S, van der Woude HJ.

Skeletal Radiol. 2009 Oct;38(10):967-75. doi: 10.1007/s00256-009-0680-3. Epub 2009 Mar 18.

11.

Accuracy of CT arthrography in the assessment of tears of the rotator cuff.

Charousset C, Bellaïche L, Duranthon LD, Grimberg J.

J Bone Joint Surg Br. 2005 Jun;87(6):824-8.

12.

Subscapularis tendon tears: detection and grading at MR arthrography.

Pfirrmann CW, Zanetti M, Weishaupt D, Gerber C, Hodler J.

Radiology. 1999 Dec;213(3):709-14.

PMID:
10580943
13.

MR arthrographic depiction of tears of the rotator cuff: benefit of abduction and external rotation of the arm.

Tirman PF, Bost FW, Steinbach LS, Mall JC, Peterfy CG, Sampson TG, Sheehan WE, Forbes JR, Genant HK.

Radiology. 1994 Sep;192(3):851-6.

PMID:
8058959
14.

Comparison of three-dimensional isotropic and two-dimensional conventional indirect MR arthrography for the diagnosis of rotator cuff tears.

Lee JH, Yoon YC, Jee S, Kwon JW, Cha JG, Yoo JC.

Korean J Radiol. 2014 Nov-Dec;15(6):771-80. doi: 10.3348/kjr.2014.15.6.771. Epub 2014 Nov 7.

15.

Comparison of three-dimensional isotropic T1-weighted fast spin-echo MR arthrography with two-dimensional MR arthrography of the shoulder.

Choo HJ, Lee SJ, Kim OH, Seo SS, Kim JH.

Radiology. 2012 Mar;262(3):921-31. doi: 10.1148/radiol.11111261. Epub 2012 Jan 20.

PMID:
22267587
16.

Comparisons of the various partial-thickness rotator cuff tears on MR arthrography and arthroscopic correlation.

Chun KA, Kim MS, Kim YJ.

Korean J Radiol. 2010 Sep-Oct;11(5):528-35. doi: 10.3348/kjr.2010.11.5.528. Epub 2010 Aug 27.

17.

Magnetic resonance arthrography including ABER view in diagnosing partial-thickness tears of the rotator cuff: accuracy, and inter- and intra-observer agreements.

Jung JY, Jee WH, Chun HJ, Ahn MI, Kim YS.

Acta Radiol. 2010 Mar;51(2):194-201. doi: 10.3109/02841850903300298.

PMID:
20001474
18.

Assessment of the long head of the biceps tendon of the shoulder with 3T magnetic resonance arthrography and CT arthrography.

De Maeseneer M, Boulet C, Pouliart N, Kichouh M, Buls N, Verhelle F, De Mey J, Shahabpour M.

Eur J Radiol. 2012 May;81(5):934-9. doi: 10.1016/j.ejrad.2011.01.121. Epub 2011 Mar 1.

PMID:
21367551
19.

Comparison study of indirect MR arthrography and direct MR arthrography of the shoulder.

Jung JY, Yoon YC, Yi SK, Yoo J, Choe BK.

Skeletal Radiol. 2009 Jul;38(7):659-67. doi: 10.1007/s00256-009-0660-7. Epub 2009 Feb 19.

PMID:
19225775
20.

Preoperative agreement on the geometric classification and 2-dimensional measurement of rotator cuff tears based on magnetic resonance arthrography.

van der Zwaal P, Thomassen BJ, Urlings TA, de Rooy TP, Swen JW, van Arkel ER.

Arthroscopy. 2012 Oct;28(10):1329-36. doi: 10.1016/j.arthro.2012.04.054. Epub 2012 Aug 10.

PMID:
22885159

Supplemental Content

Support Center