Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 113

1.

Validation for clinical use of a novel HIV-2 plasma RNA viral load assay using the Abbott m2000 platform.

Chang M, Gottlieb GS, Dragavon JA, Cherne SL, Kenney DL, Hawes SE, Smith RA, Kiviat NB, Sow PS, Coombs RW.

J Clin Virol. 2012 Oct;55(2):128-33. doi: 10.1016/j.jcv.2012.06.024. Epub 2012 Jul 24.

2.

Comparison of HIV-1 RNA measurements obtained by using plasma and dried blood spots in the automated abbott real-time viral load assay.

Arredondo M, Garrido C, Parkin N, Zahonero N, Bertagnolio S, Soriano V, de Mendoza C.

J Clin Microbiol. 2012 Mar;50(3):569-72. doi: 10.1128/JCM.00418-11. Epub 2011 Dec 14.

3.

Validation and clinical use of a sensitive HIV-2 viral load assay that uses a whole virus internal control.

Styer LM, Miller TT, Parker MM.

J Clin Virol. 2013 Dec;58 Suppl 1:e127-33. doi: 10.1016/j.jcv.2013.09.007. Epub 2013 Sep 13.

PMID:
24342472
4.

Quantitative detection of plasma human immunodeficiency virus type 2 subtype A RNA by the Nuclisens EasyQ Assay (version 1.1).

Rodés B, Sheldon J, Toro C, Cuevas L, Pérez-Pastrana E, Herrera I, Soriano V.

J Clin Microbiol. 2007 Jan;45(1):88-92. Epub 2006 Nov 8.

5.

Comparison of the Abbott m2000 HIV-1 Real-Time and Roche AMPLICOR Monitor v1.5 HIV-1 assays on plasma specimens from Rakai, Uganda.

Ssebugenyi I, Kizza A, Mpoza B, Aluma G, Boaz I, Newell K, Laeyendecker O, Shott JP, Serwadda D, Reynolds SJ.

Int J STD AIDS. 2011 Jul;22(7):373-5. doi: 10.1258/ijsa.2009.009526.

6.

Highly sensitive plasma RNA quantification by real-time PCR in HIV-2 group A and group B infection.

Delarue S, Didier E, Damond F, Ponscarme D, Brengle-Pesce K, Resche-Rigon M, Vray M, Gueudin M, Simon F.

J Clin Virol. 2013 Oct;58(2):461-7. doi: 10.1016/j.jcv.2013.08.003. Epub 2013 Aug 14.

PMID:
24008204
7.

An in-house assay for BK polyomavirus quantification using the Abbott m2000 RealTime system.

Muldrew KL, Lovett JL.

J Med Microbiol. 2013 Nov;62(Pt 11):1714-20. doi: 10.1099/jmm.0.058388-0. Epub 2013 Aug 7.

PMID:
23924663
8.

Comparison of Three Different FDA-Approved Plasma HIV-1 RNA Assay Platforms Confirms the Virologic Failure Endpoint of 200 Copies per Milliliter Despite Improved Assay Sensitivity.

Lalama CM, Jennings C, Johnson VA, Coombs RW, McKinnon JE, Bremer JW, Cobb BR, Cloherty GA, Mellors JW, Ribaudo HJ; AIDS Clinical Trials Group.

J Clin Microbiol. 2015 Aug;53(8):2659-66. doi: 10.1128/JCM.00801-15. Epub 2015 Jun 10.

10.

Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece.

Katsoulidou A, Rokka C, Issaris C, Haida C, Tzannis K, Sypsa V, Detsika M, Paraskevis D, Hatzakis A.

Virol J. 2011 Jan 11;8:10. doi: 10.1186/1743-422X-8-10.

11.

Preparation and evaluation of the 1st international standard for the quantitation of HIV-2 RNA in plasma.

Holmes H, Berry N, Heath A, Morris C.

J Virol Methods. 2011 Aug;175(2):246-52. doi: 10.1016/j.jviromet.2011.05.025. Epub 2011 May 27.

PMID:
21640139
12.

Development of a real-time quantitative RT-PCR for the detection of HIV-2 RNA in plasma.

Schutten M, van den Hoogen B, van der Ende ME, Gruters RA, Osterhaus AD, Niesters HG.

J Virol Methods. 2000 Jul;88(1):81-7.

PMID:
10921845
13.

Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays.

Hopkins M, Hau S, Tiernan C, Papadimitropoulos A, Chawla A, Beloukas A, Geretti AM.

J Clin Virol. 2015 Aug;69:56-62. doi: 10.1016/j.jcv.2015.05.020. Epub 2015 May 29.

14.

Measurement of viral load by the automated Abbott real-time HIV-1 assay using dried blood spots collected and processed in Malawi and Mozambique.

Erba F, Brambilla D, Ceffa S, Ciccacci F, Luhanga R, Sidumo Z, Palombi L, Mancinelli S, Marazzi MC, Andreotti M, Giuliano M.

S Afr Med J. 2015 Nov 8;105(12):1036-8. doi: 10.7196/SAMJ.2015.v105i12.9673.

PMID:
26792161
15.

Evaluation of different RNA extraction methods and storage conditions of dried plasma or blood spots for human immunodeficiency virus type 1 RNA quantification and PCR amplification for drug resistance testing.

Monleau M, Montavon C, Laurent C, Segondy M, Montes B, Delaporte E, Boillot F, Peeters M.

J Clin Microbiol. 2009 Apr;47(4):1107-18. doi: 10.1128/JCM.02255-08. Epub 2009 Feb 4.

16.

High correlation between the Roche COBAS® AmpliPrep/COBAS® TaqMan® HIV-1, v2.0 and the Abbott m2000 RealTime HIV-1 assays for quantification of viral load in HIV-1 B and non-B subtypes.

Karasi JC, Dziezuk F, Quennery L, Förster S, Reischl U, Colucci G, Schoener D, Seguin-Devaux C, Schmit JC.

J Clin Virol. 2011 Nov;52(3):181-6. doi: 10.1016/j.jcv.2011.07.002. Epub 2011 Aug 3.

PMID:
21813320
17.

Comparative evaluation of the Artus HIV-1 QS-RGQ assay and the Abbott RealTime HIV-1 assay for the quantification of HIV-1 RNA in plasma.

Garcia-Diaz A, Labbett W, Clewley GS, Guerrero-Ramos A, Geretti AM.

J Clin Virol. 2013 May;57(1):66-9. doi: 10.1016/j.jcv.2013.01.006. Epub 2013 Jan 28.

PMID:
23369887
18.

Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma.

Erice A, Brambilla D, Bremer J, Jackson JB, Kokka R, Yen-Lieberman B, Coombs RW.

J Clin Microbiol. 2000 Aug;38(8):2837-45.

19.
20.

A new quantitative HIV load assay based on plasma virion reverse transcriptase activity for the different types, groups and subtypes.

Braun J, Plantier JC, Hellot MF, Tuaillon E, Gueudin M, Damond F, Malmsten A, Corrigan GE, Simon F.

AIDS. 2003 Feb 14;17(3):331-6.

PMID:
12556686

Supplemental Content

Support Center