Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 102

1.

Optimizing the pacing site in the ventricular septum by fluoroscopy and morphology of the paced QRS complex.

Kamenik L, Sedlon P, Hnatek T, Krcova E, Jarkovsky J, Taborsky M.

Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2013 Mar;157(1):56-63. doi: 10.5507/bp.2011.063.

2.

Right ventricular septal pacing- clinical and electrical predictors for LV contraction asynchrony.

Iorgulescu C, Radu DA, Constantinescu D, Caldararu C, Dorobantu M.

J Med Life. 2014;7 Spec No. 4:83-9.

3.

Radiological and electrocardiographic characterization of right ventricular outflow tract pacing.

Balt JC, van Hemel NM, Wellens HJ, de Voogt WG.

Europace. 2010 Dec;12(12):1739-44. doi: 10.1093/europace/euq341.

4.

Effect of right ventricular pacing site on QRS width.

Nakamura H, Mine T, Kanemori T, Ohyanagi M, Masuyama T.

Asian Cardiovasc Thorac Ann. 2011 Oct;19(5):339-45. doi: 10.1177/0218492311422485.

PMID:
22100929
5.

The relationship between right ventricular lead position and paced QRS duration.

Kawakami T, Tanaka N, Ohno H, Kobayakawa H, Sakurai T, Ishihara H, Ohmori H, Matsuzaki T.

Pacing Clin Electrophysiol. 2013 Feb;36(2):187-93. doi: 10.1111/pace.12047.

PMID:
23252677
6.
7.

Localization of precise origin of idiopathic ventricular tachycardia from the right ventricular outflow tract by a 12-lead ECG: a study of pace mapping using a multielectrode "basket" catheter.

Yoshida Y, Hirai M, Murakami Y, Kondo T, Inden Y, Akahoshi M, Tsuda M, Okamoto M, Yamada T, Tsuboi N, Hirayama H, Ito T, Toyama J, Saito H.

Pacing Clin Electrophysiol. 1999 Dec;22(12):1760-8.

PMID:
10642129
8.

Right ventricular outflow tract pacing: radiographic and electrocardiographic correlates of lead position.

McGavigan AD, Roberts-Thomson KC, Hillock RJ, Stevenson IH, Mond HG.

Pacing Clin Electrophysiol. 2006 Oct;29(10):1063-8.

PMID:
17038137
9.

The relation between the pacing sites in the right ventricular outflow tract and QRS morphology in the 12-lead ECG.

Shima T, Ohnishi Y, Inoue T, Yoshida A, Shimizu H, Itagaki T, Sekiya J, Yamashiro K, Takei A, Adachi K, Yokoyama M.

Jpn Circ J. 1998 Jun;62(6):399-404.

10.

Alternate site right ventricular pacing: defining template scoring.

Mond HG, Feldman A, Kumar S, Rosso R, Hung TT, Pang B.

Pacing Clin Electrophysiol. 2011 Sep;34(9):1080-6. doi: 10.1111/j.1540-8159.2011.03129.x.

PMID:
21605136
11.

The right ventricular outflow tract: a comparative study of septal, anterior wall, and free wall pacing.

Hillock RJ, Stevenson IH, Mond HG.

Pacing Clin Electrophysiol. 2007 Aug;30(8):942-7.

PMID:
17669075
12.

Selective site pacing from the right ventricular mid-septum. Follow-up of lead performance and procedure technique.

Yusu S, Mera H, Hoshida K, Miyakoshi M, Miwa Y, Tsukada T, Yoshino H, Ikeda T.

Int Heart J. 2012;53(2):113-6.

13.

Influence of right ventricular stimulation site on left ventricular function in atrial synchronous ventricular pacing.

Schwaab B, Fröhlig G, Alexander C, Kindermann M, Hellwig N, Schwerdt H, Kirsch CM, Schieffer H.

J Am Coll Cardiol. 1999 Feb;33(2):317-23.

14.

[Comparison of basic electrical features of ICD defibrillating leads implanted to right ventricular apex or right ventricular outflow track and septum].

Szafraniec Z, Kaczmarek K, Pałka K, Ptaszyński P, Ruta J, Chudzik M, Wranicz JK.

Pol Merkur Lekarski. 2014 Mar;36(213):155-9. Polish.

PMID:
24779211
15.

Analysis of the electrocardiographic waveforms produced by right ventricular pacing: relation to the nonpaced patterns.

Friedman HS.

Pacing Clin Electrophysiol. 2008 May;31(5):529-35. doi: 10.1111/j.1540-8159.2008.01036.x.

PMID:
18439164
16.

Paced QRS morphology for confirming septal pacemaker lead implantation: correction of a misconception.

Burri H.

Europace. 2010 Dec;12(12):1660-1. doi: 10.1093/europace/euq377. No abstract available.

17.

A stepwise electrocardiographic algorithm for differentiation of mid-septal vs. apical right ventricular lead positioning: the SPICE ECG substudy.

Andrikopoulos G, Tzeis S, Asbach S, Semmler V, Lennerz C, Solzbach U, Grebmer C, Kloppe A, Klein N, Pastromas S, Biermann J, Kolb C; SPICE Study Investigators..

Europace. 2015 Jun;17(6):915-20. doi: 10.1093/europace/euu344.

18.

Right ventricular septal pacing: a comparative study of outflow tract and mid ventricular sites.

Rosso R, Medi C, Teh AW, Hung TT, Feldman A, Lee G, Mond HG.

Pacing Clin Electrophysiol. 2010 Oct;33(10):1169-73. doi: 10.1111/j.1540-8159.2010.02836.x.

PMID:
20636311
19.

Morphology of ventricular arrhythmias in the boxer as measured by 12-lead electrocardiography with pace-mapping comparison.

Kraus MS, Moïse NS, Rishniw M, Dykes N, Erb HN.

J Vet Intern Med. 2002 Mar-Apr;16(2):153-8.

20.

Prolonged paced QRS duration as a predictor for congestive heart failure in patients with right ventricular apical pacing.

Miyoshi F, Kobayashi Y, Itou H, Onuki T, Matsuyama T, Watanabe N, Liu C, Kawamura M, Asano T, Miyata A, Nakagawa H, Tanno K, Baba T, Katagiri T.

Pacing Clin Electrophysiol. 2005 Nov;28(11):1182-8.

PMID:
16359284
Items per page

Supplemental Content

Support Center