Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 157

1.

The impact of amplitude-integrated electroencephalography on NICU practice.

Appendino JP, McNamara PJ, Keyzers M, Stephens D, Hahn CD.

Can J Neurol Sci. 2012 May;39(3):355-60.

PMID:
22547518
2.

Utility of prolonged bedside amplitude-integrated encephalogram in encephalopathic infants.

Mathur AM, Morris LD, Teteh F, Inder TE, Zempel J.

Am J Perinatol. 2008 Nov;25(10):611-5. doi: 10.1055/s-0028-1090598. Epub 2008 Oct 7.

PMID:
18841534
3.

Acute neonatal encephalopathy and seizures recurrence: a combined aEEG/EEG study.

Mastrangelo M, Fiocchi I, Fontana P, Gorgone G, Lista G, Belcastro V.

Seizure. 2013 Nov;22(9):703-7. doi: 10.1016/j.seizure.2013.05.006. Epub 2013 May 29.

4.

Recording conventional and amplitude-integrated EEG in neonatal intensive care unit.

Neubauer D, Osredkar D, Paro-Panjan D, Skofljanec A, Derganc M.

Eur J Paediatr Neurol. 2011 Sep;15(5):405-16. doi: 10.1016/j.ejpn.2011.03.001. Epub 2011 Jul 29. Review.

PMID:
21802965
5.

How to use: amplitude-integrated EEG (aEEG).

Shah NA, Wusthoff CJ.

Arch Dis Child Educ Pract Ed. 2015 Apr;100(2):75-81. doi: 10.1136/archdischild-2013-305676. Epub 2014 Jul 17. Review.

PMID:
25035312
6.

Clinical utility of early amplitude integrated EEG in monitoring term newborns at risk of neurological injury.

Toso PA, González AJ, Pérez ME, Kattan J, Fabres JG, Tapia JL, González HS.

J Pediatr (Rio J). 2014 Mar-Apr;90(2):143-8. doi: 10.1016/j.jped.2013.07.004. Epub 2013 Oct 30.

7.

Accuracy of amplitude integrated EEG in a neonatal cohort.

Evans E, Koh S, Lerner J, Sankar R, Garg M.

Arch Dis Child Fetal Neonatal Ed. 2010 May;95(3):F169-73. doi: 10.1136/adc.2009.165969.

PMID:
20444809
8.

Single-channel amplitude integrated EEG recording for the identification of epileptic seizures by nonexpert physicians in the adult acute care setting.

Nitzschke R, Müller J, Engelhardt R, Schmidt GN.

J Clin Monit Comput. 2011 Oct;25(5):329-37. doi: 10.1007/s10877-011-9312-2. Epub 2011 Oct 19.

PMID:
22009108
9.

Single versus bihemispheric amplitude-integrated electroencephalography in relation to cerebral injury and outcome in the term encephalopathic infant.

Lavery S, Shah DK, Hunt RW, Filan PM, Doyle LW, Inder TE.

J Paediatr Child Health. 2008 May;44(5):285-90. doi: 10.1111/j.1440-1754.2007.01270.x.

PMID:
18416705
10.

Diagnostic value of amplitude-integrated electroencephalogram in neonatal seizures.

Zhang L, Zhou YX, Chang LW, Luo XP.

Neurosci Bull. 2011 Aug;27(4):251-7. doi: 10.1007/s12264-011-1413-x.

PMID:
21788996
11.

[Continuous two channel electroencephalography: description, applications, benefits and pitfalls].

Bednarek N, Delebarre G, Saad S, Loron G, Mezguiche F, Morville P.

Arch Pediatr. 2008 Aug;15(8):1326-31. doi: 10.1016/j.arcped.2008.04.033. Epub 2008 Jun 26. Review. French.

PMID:
18585014
12.

Detection of subclinical electroencephalographic seizure patterns with multichannel amplitude-integrated EEG in full-term neonates.

Bourez-Swart MD, van Rooij L, Rizzo C, de Vries LS, Toet MC, Gebbink TA, Ezendam AG, van Huffelen AC.

Clin Neurophysiol. 2009 Nov;120(11):1916-22. doi: 10.1016/j.clinph.2009.08.015. Epub 2009 Sep 25.

PMID:
19782640
13.

Long-term monitoring of a critically ill preterm infant with two-channel amplitude integrated electroencephalography.

Kazanci E, Kolsal E, Ergenekon E, Vural O, Gucuyener K.

Neuropediatrics. 2011 Dec;42(6):237-9. doi: 10.1055/s-0031-1297932. Epub 2011 Dec 5.

PMID:
22144011
14.

Need for quality control for aEEG monitoring of the preterm infant: a 2-year experience.

Griesmaier E, Neubauer V, Ralser E, Trawöger R, Kiechl-Kohlendorfer U, Keller M.

Acta Paediatr. 2011 Aug;100(8):1079-83. doi: 10.1111/j.1651-2227.2011.02206.x. Epub 2011 Mar 22.

PMID:
21352354
15.

Clinical severity, rather than body temperature, during the rewarming phase of therapeutic hypothermia affect quantitative EEG in neonates with hypoxic ischemic encephalopathy.

Burnsed J, Quigg M, Zanelli S, Goodkin HP.

J Clin Neurophysiol. 2011 Feb;28(1):10-4. doi: 10.1097/WNP.0b013e318205134b.

PMID:
21221006
16.

[The application of amplitude-integrated EEG in the cerebral function monitoring of neonates].

Zhang D, Ding H, Ye D.

Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008 Aug;25(4):950-3. Review. Chinese.

PMID:
18788316
17.

Impact of amplitude-integrated electroencephalograms on clinical care for neonates with seizures.

Shellhaas RA, Barks AK.

Pediatr Neurol. 2012 Jan;46(1):32-5. doi: 10.1016/j.pediatrneurol.2011.11.004.

18.

Brief electroencephalography rhythmic discharges (BERDs) in the neonate with seizures: their significance and prognostic implications.

Nagarajan L, Palumbo L, Ghosh S.

J Child Neurol. 2011 Dec;26(12):1529-33. doi: 10.1177/0883073811409750. Epub 2011 Jun 7.

PMID:
21652591
19.

Assessment of neonatal electroencephalography (EEG) background by conventional and two amplitude-integrated EEG classification systems.

Shellhaas RA, Gallagher PR, Clancy RR.

J Pediatr. 2008 Sep;153(3):369-74. doi: 10.1016/j.jpeds.2008.03.004. Epub 2008 Apr 18.

PMID:
18534239
20.

Amplitude-integrated EEG for detection of neonatal seizures: a systematic review.

Rakshasbhuvankar A, Paul S, Nagarajan L, Ghosh S, Rao S.

Seizure. 2015 Dec;33:90-8. doi: 10.1016/j.seizure.2015.09.014. Epub 2015 Sep 26. Review.

Supplemental Content

Support Center