Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 113

1.

Quantitative Cherenkov emission spectroscopy for tissue oxygenation assessment.

Axelsson J, Glaser AK, Gladstone DJ, Pogue BW.

Opt Express. 2012 Feb 27;20(5):5133-42. doi: 10.1364/OE.20.005133.

2.

Time-gated Cherenkov emission spectroscopy from linear accelerator irradiation of tissue phantoms.

Glaser AK, Zhang R, Davis SC, Gladstone DJ, Pogue BW.

Opt Lett. 2012 Apr 1;37(7):1193-5. doi: 10.1364/OL.37.001193.

3.

Determination of oxygen saturation and hematocrit of flowing human blood using two different spectrally resolving sensors.

Meinke M, Müller G, Gersonde I, Friebel M.

Biomed Tech (Berl). 2006 Dec;51(5-6):347-54.

PMID:
17155871
6.

Design of a visible-light spectroscopy clinical tissue oximeter.

Benaron DA, Parachikov IH, Cheong WF, Friedland S, Rubinsky BE, Otten DM, Liu FW, Levinson CJ, Murphy AL, Price JW, Talmi Y, Weersing JP, Duckworth JL, Hörchner UB, Kermit EL.

J Biomed Opt. 2005 Jul-Aug;10(4):44005.

PMID:
16178639
7.

Optical fiber probe spectroscopy for laparoscopic monitoring of tissue oxygenation during esophagectomies.

Gareau DS, Truffer F, Perry KA, Pham TH, Enestvedt CK, Dolan JP, Hunter JG, Jacques SL.

J Biomed Opt. 2010 Nov-Dec;15(6):061712. doi: 10.1117/1.3512149. Erratum in: J Biomed Opt. 2011 Mar;16(3):039801. Perry, Kyle [corrected to Perry, Kyle A]; Pham, Thai [corrected to Pham, Thai H]; Dolan, James [corrected to Dolan, James P].

8.

Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

Häggblad E, Lindbergh T, Karlsson MG, Casimir-Ahn H, Salerud EG, Strömberg T.

J Biomed Opt. 2008 Sep-Oct;13(5):054030. doi: 10.1117/1.2976433.

PMID:
19021410
9.

Applications of quantum dots in optical fiber luminescent oxygen sensors.

Jorge PA, Mayeh M, Benrashid R, Caldas P, Santos JL, Farahi F.

Appl Opt. 2006 Jun 1;45(16):3760-7.

PMID:
16724134
10.

Investigation of an optical fiber cerebral oximeter using a Monte Carlo model.

Phillips JP, Langford RM, Jones DP.

Conf Proc IEEE Eng Med Biol Soc. 2007;2007:1113-6.

PMID:
18002157
11.

Optical imaging of hemoglobin oxygen saturation using a small number of spectral images for endoscopic application.

Saito T, Yamaguchi H.

J Biomed Opt. 2015;20(12):126011. doi: 10.1117/1.JBO.20.12.126011.

PMID:
26720878
12.

Oxygen measurement by multimode diode lasers employing gas correlation spectroscopy.

Lou X, Somesfalean G, Chen B, Zhang Z.

Appl Opt. 2009 Feb 10;48(5):990-7.

PMID:
19209216
13.

Noninvasive measurement of total hemoglobin and hemoglobin derivatives using multiwavelength pulse spectrophotometry -In vitro study with a mock circulatory system.

Suzaki H, Kobayashi N, Nagaoka T, Iwasaki K, Umezu M, Takeda S, Togawa T.

Conf Proc IEEE Eng Med Biol Soc. 2006;1:799-802.

PMID:
17946423
14.

Measuring tumor cycling hypoxia and angiogenesis using a side-firing fiber optic probe.

Yu B, Shah A, Wang B, Rajaram N, Wang Q, Ramanujam N, Palmer GM, Dewhirst MW.

J Biophotonics. 2014 Jul;7(7):552-64. doi: 10.1002/jbio.201200187.

15.

Fiber-optic Cherenkov radiation in the few-cycle regime.

Chang G, Chen LJ, Kärtner FX.

Opt Express. 2011 Mar 28;19(7):6635-47. doi: 10.1364/OE.19.006635.

PMID:
21451691
16.

Inverse Monte Carlo method in a multilayered tissue model for diffuse reflectance spectroscopy.

Fredriksson I, Larsson M, Strömberg T.

J Biomed Opt. 2012 Apr;17(4):047004. doi: 10.1117/1.JBO.17.4.047004.

PMID:
22559695
17.

Multifrequency frequency-domain spectrometer for tissue analysis.

Spichtig S, Hornung R, Brown DW, Haensse D, Wolf M.

Rev Sci Instrum. 2009 Feb;80(2):024301. doi: 10.1063/1.3082024.

PMID:
19256664
18.

In vivo depth-resolved oxygen saturation by Dual-Wavelength Photothermal (DWP) OCT.

Kuranov RV, Kazmi S, McElroy AB, Kiel JW, Dunn AK, Milner TE, Duong TQ.

Opt Express. 2011 Nov 21;19(24):23831-44. doi: 10.1364/OE.19.023831.

19.

An optical fiber photoplethysmographic system for central nervous system tissue.

Phillips JP, Kyriacou PA, George KJ, Priestley JV, Langford RM.

Conf Proc IEEE Eng Med Biol Soc. 2006;1:803-6.

PMID:
17946001
20.

In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy.

Chen Z, Yang S, Xing D.

Opt Lett. 2012 Aug 15;37(16):3414-6. doi: 10.1364/OL.37.003414.

PMID:
23381275
Items per page

Supplemental Content

Support Center