Links from PubMed

Items: 1 to 20 of 145

1.

Influence of a resilient, hard-carbon thin film on drilling efficiency and thermogenesis.

Gasiorowski JC, Richardson DW, Boston RC, Schaer TP.

Vet Surg. 2011 Oct;40(7):875-80. doi: 10.1111/j.1532-950X.2011.00894.x. Epub 2011 Sep 20.

PMID:
22380671
2.

In vitro comparison of cortical bone temperature generation between traditional sequential drilling and a newly designed step drill in the equine third metacarpal bone.

Bubeck KA, García-López J, Maranda LS.

Vet Comp Orthop Traumatol. 2009;22(6):442-7. doi: 10.3415/VCOT-09-03-0029. Epub 2009 Oct 29.

PMID:
19876527
3.

Performance test of different 3.5 mm drill bits and consequences for orthopaedic surgery.

Clement H, Zopf C, Brandner M, Tesch NP, Vallant R, Puchwein P.

Arch Orthop Trauma Surg. 2015 Dec;135(12):1675-82. doi: 10.1007/s00402-015-2338-z. Epub 2015 Sep 25.

PMID:
26407980
4.

Effect of sequential hole enlargement on cortical bone temperature during drilling of 6.2-mm-diameter transcortical holes in the third metacarpal bones of horse cadavers.

Lescun TB, Frank EA, Zacharias JR, Daggy JK, Moore GE.

Am J Vet Res. 2011 Dec;72(12):1687-94. doi: 10.2460/ajvr.72.12.1687.

PMID:
22126699
5.

Heat Generation During Bone Drilling: A Comparison Between Industrial and Orthopaedic Drill Bits.

Hein C, Inceoglu S, Juma D, Zuckerman L.

J Orthop Trauma. 2017 Feb;31(2):e55-e59. doi: 10.1097/BOT.0000000000000723.

PMID:
27682019
6.

Plunging when drilling: effect of using blunt drill bits.

Alajmo G, Schlegel U, Gueorguiev B, Matthys R, Gautier E.

J Orthop Trauma. 2012 Aug;26(8):482-7. doi: 10.1097/BOT.0b013e3182336ec3.

PMID:
22391404
7.

Surgical drilling: design and performance of an improved drill.

Saha S, Pal S, Albright JA.

J Biomech Eng. 1982 Aug;104(3):245-52.

PMID:
7120951
8.

Heat production by 3 implant drill systems after repeated drilling and sterilization.

Chacon GE, Bower DL, Larsen PE, McGlumphy EA, Beck FM.

J Oral Maxillofac Surg. 2006 Feb;64(2):265-9.

PMID:
16413899
9.

Effect of surgical drill guide on heat generated from implant drilling.

Misir AF, Sumer M, Yenisey M, Ergioglu E.

J Oral Maxillofac Surg. 2009 Dec;67(12):2663-8. doi: 10.1016/j.joms.2009.07.056.

PMID:
19925988
10.
11.

The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability.

Ercoli C, Funkenbusch PD, Lee HJ, Moss ME, Graser GN.

Int J Oral Maxillofac Implants. 2004 May-Jun;19(3):335-49.

PMID:
15214217
12.

Orthopaedic bone drills-can they be improved? Temperature changes near the drilling face.

Natali C, Ingle P, Dowell J.

J Bone Joint Surg Br. 1996 May;78(3):357-62.

13.

The effect of drill bit, pin, and wire tip design on drilling.

Fincham BM, Jaeblon T.

J Am Acad Orthop Surg. 2011 Sep;19(9):574-9. Review.

PMID:
21885703
14.

Effects of bone drilling on local temperature and bone regeneration: an in vivo study.

Karaca F, Aksakal B, Köm M.

Acta Orthop Traumatol Turc. 2014;48(3):326-32. doi: 10.3944/AOTT.2014.3074.

15.

Temperature rise during drilling through bone.

Abouzgia MB, James DF.

Int J Oral Maxillofac Implants. 1997 May-Jun;12(3):342-53. Review.

PMID:
9197099
16.

Influence of the implant drill design and sequence on temperature changes during site preparation.

Sannino G, Capparé P, Gherlone EF, Barlattani A.

Int J Oral Maxillofac Implants. 2015 Mar-Apr;30(2):351-8. doi: 10.11607/jomi.3747. Epub 2014 Dec 5.

PMID:
25153005
17.

Effect of feed rate and drill speed on temperatures in equine cortical bone.

Toews AR, Bailey JV, Townsend HG, Barber SM.

Am J Vet Res. 1999 Aug;60(8):942-4.

PMID:
10451201
18.

Influence of tool geometry on drilling performance of cortical and trabecular bone.

Tuijthof GJ, Frühwirt C, Kment C.

Med Eng Phys. 2013 Aug;35(8):1165-72. doi: 10.1016/j.medengphy.2012.12.004. Epub 2013 Jan 6.

PMID:
23298783
19.

The effects of drilling force on cortical temperatures and their duration: an in vitro study.

Bachus KN, Rondina MT, Hutchinson DT.

Med Eng Phys. 2000 Dec;22(10):685-91.

PMID:
11334754
20.

Accuracy study of computer-assisted drilling: the effect of bone density, drill bit characteristics, and use of a mechanical guide.

Hüfner T, Geerling J, Oldag G, Richter M, Kfuri M Jr, Pohlemann T, Krettek C.

J Orthop Trauma. 2005 May-Jun;19(5):317-22.

PMID:
15891540