Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 153

1.

Root Cause Investigation of Rubber Seal Cracking in Pre-filled Cartridges: Ozone and Packaging Effects.

Chan EK, Hubbard A, Hsu CC, Vedrine L, Maa YF.

PDA J Pharm Sci Technol. 2011 Sep-Oct;65(5):445-56. doi: 10.5731/pdajpst.2011.00769.

PMID:
22293834
2.

Container/Closure Integrity Testing and the Identification of a Suitable Vial/Stopper Combination for Low-Temperature Storage at -80 {degrees}C.

Zuleger B, Werner U, Kort A, Glowienka R, Wehnes E, Duncan D.

PDA J Pharm Sci Technol. 2012 Sep-Oct;66(5):453-65. doi: 10.5731/pdajpst.2012.00884.

PMID:
23035029
3.

Mass extraction container closure integrity physical testing method development for parenteral container closure systems.

Yoon SY, Sagi H, Goldhammer C, Li L.

PDA J Pharm Sci Technol. 2012 Sep-Oct;66(5):403-19. doi: 10.5731/pdajpst.2012.00878.

PMID:
23035025
4.

Delamination propensity of pharmaceutical glass containers by accelerated testing with different extraction media.

Guadagnino E, Zuccato D.

PDA J Pharm Sci Technol. 2012 Mar-Apr;66(2):116-25. doi: 10.5731/pdajpst.2012.00853.

PMID:
22492597
5.

Practical fundamentals of glass, rubber, and plastic sterile packaging systems.

Sacha GA, Saffell-Clemmer W, Abram K, Akers MJ.

Pharm Dev Technol. 2010 Jan-Feb;15(1):6-34. doi: 10.3109/10837450903511178. Review.

PMID:
20088708
6.

Novel Mechanism of Glass Delamination in Type 1A Borosilicate Vials Containing Frozen Protein Formulations.

Jiang G, Goss M, Li G, Jing W, Shen H, Fujimori K, Le L, Wong L, Wen ZQ, Nashed-Samuel Y, Riker K, Germansderfer A, Tsang P, Ricci M.

PDA J Pharm Sci Technol. 2013 Jul-Aug;67(4):323-35. doi: 10.5731/pdajpst.2013.00925.

PMID:
23872443
7.

Low Leachable Container System Consisting of a Polymer-Based Syringe with Chlorinated Isoprene Isobutene Rubber Plunger Stopper.

Kiminami H, Takeuchi K, Nakamura K, Abe Y, Lauwers P, Dierick W, Yoshino K, Suzuki S.

PDA J Pharm Sci Technol. 2015 Nov-Dec;69(6):713-24. doi: 10.5731/pdajpst.2015.01080.

PMID:
26659102
8.
10.

Stability of intravenous nitroglycerin solutions.

Scheife AH, Grisafe JA, Shargel L.

J Pharm Sci. 1982 Jan;71(1):55-9.

PMID:
6799641
11.

Evaluation of Container Closure System Integrity for Frozen Storage Drug Products.

Nieto A, Roehl H, Brown H, Nikoloff J, Adler M, Mahler HC.

PDA J Pharm Sci Technol. 2016 Mar-Apr;70(2):120-33. doi: 10.5731/pdajpst.2015.006098. Epub 2016 Jan 21.

PMID:
26797976
12.

The pharmaceutical vial capping process: Container closure systems, capping equipment, regulatory framework, and seal quality tests.

Mathaes R, Mahler HC, Buettiker JP, Roehl H, Lam P, Brown H, Luemkemann J, Adler M, Huwyler J, Streubel A, Mohl S.

Eur J Pharm Biopharm. 2016 Feb;99:54-64. doi: 10.1016/j.ejpb.2015.11.016. Epub 2015 Nov 30. Review.

PMID:
26654992
13.

Selection of containers and closure systems for injectable products.

Nedich RL.

Am J Hosp Pharm. 1983 Nov;40(11):1924-7.

PMID:
6650521
14.

Microbial barrier assessment of Tyvek stopper packaging for rubber closures.

Moldenhauer JE, Bass SA, Kupinski MJ, Walters ML, Rubio SL.

PDA J Pharm Sci Technol. 1996 Nov-Dec;50(6):391-8.

PMID:
9038086
15.

Physical stability of 20% lipid injectable emulsions via simulated syringe infusion: effects of glass vs plastic product packaging.

Driscoll DF, Ling PR, Bistrian BR.

JPEN J Parenter Enteral Nutr. 2007 Mar-Apr;31(2):148-53. Erratum in: JPEN J Parenter Enteral Nutr. 2007 May-Jun;31(3):261.

PMID:
17308256
16.

Extractables characterization for five materials of construction representative of packaging systems used for parenteral and ophthalmic drug products.

Jenke D, Castner J, Egert T, Feinberg T, Hendricker A, Houston C, Hunt DG, Lynch M, Shaw A, Nicholas K, Norwood DL, Paskiet D, Ruberto M, Smith EJ, Holcomb F.

PDA J Pharm Sci Technol. 2013 Sep-Oct;67(5):448-511. doi: 10.5731/pdajpst.2013.00933.

PMID:
24084660
18.

Aluminum and Phthalates in Calcium Gluconate: Contribution From Glass and Plastic Packaging.

Yokel RA, Unrine JM.

J Pediatr Gastroenterol Nutr. 2017 Jan;64(1):109-114. doi: 10.1097/MPG.0000000000001243.

PMID:
27111341
19.

Enhancing patient safety through the use of a pharmaceutical glass designed to prevent cracked containers.

Schaut RA, Hoff KC, DeMartino SE, Denson WK, Verkleeren RL.

PDA J Pharm Sci Technol. 2017 Sep 19. pii: pdajpst.2017.007807. doi: 10.5731/pdajpst.2017.007807. [Epub ahead of print]

PMID:
28928290
20.

Supplemental Content

Support Center