Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 133

1.

Material attrition and bone micromorphology after conventional and ultrasonic implant site preparation.

Rashad A, Sadr-Eshkevari P, Weuster M, Schmitz I, Prochnow N, Maurer P.

Clin Oral Implants Res. 2013 Aug;24 Suppl A100:110-4. doi: 10.1111/j.1600-0501.2011.02389.x. Epub 2012 Jan 17.

PMID:
22248387
2.

Heat production during different ultrasonic and conventional osteotomy preparations for dental implants.

Rashad A, Kaiser A, Prochnow N, Schmitz I, Hoffmann E, Maurer P.

Clin Oral Implants Res. 2011 Dec;22(12):1361-5. doi: 10.1111/j.1600-0501.2010.02126.x. Epub 2011 Mar 21.

PMID:
21435005
3.

Piezoelectric vs. conventional implant site preparation: ex vivo implant primary stability.

Baker JA, Vora S, Bairam L, Kim HI, Davis EL, Andreana S.

Clin Oral Implants Res. 2012 Apr;23(4):433-7. doi: 10.1111/j.1600-0501.2011.02286.x. Epub 2011 Sep 15.

PMID:
22092442
4.

Ultrasonic versus drills implant site preparation: a histologic analysis in bovine ribs.

Scarano A, Iezzi G, Perrotti V, Tetè S, Staiti G, Mortellaro C, Cappucci C.

J Craniofac Surg. 2014 May;25(3):814-7. doi: 10.1097/SCS.0000000000000713.

PMID:
24777015
5.

Piezosurgery applied to implant dentistry: clinical and biological aspects.

Pereira CC, Gealh WC, Meorin-Nogueira L, Garcia-Júnior IR, Okamoto R.

J Oral Implantol. 2014 Jul;40 Spec No:401-8. doi: 10.1563/AAID-JOI-D-11-00196. Review.

PMID:
25020222
6.

Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills.

Oliveira N, Alaejos-Algarra F, Mareque-Bueno J, Ferrés-Padró E, Hernández-Alfaro F.

Clin Oral Implants Res. 2012 Aug;23(8):963-9. doi: 10.1111/j.1600-0501.2011.02248.x. Epub 2011 Aug 2.

PMID:
21806686
7.

Micromorphometrical analyses of five different ultrasonic osteotomy devices at the rabbit skull.

Hollstein S, Hoffmann E, Vogel J, Heyroth F, Prochnow N, Maurer P.

Clin Oral Implants Res. 2012 Jun;23(6):713-8. doi: 10.1111/j.1600-0501.2011.02185.x. Epub 2011 Apr 13.

PMID:
21488969
8.

Primary stability comparison using piezoelectric or conventional implant site preparation systems in cancellous bone: a pilot study.

Gandhi SA, Baker JA, Bairam L, Kim HI, Davis EL, Andreana S.

Implant Dent. 2014 Feb;23(1):79-84. doi: 10.1097/ID.0000000000000022.

PMID:
24398848
9.

Intraosseous heat generation during sonic, ultrasonic and conventional osteotomy.

Rashad A, Sadr-Eshkevari P, Heiland M, Smeets R, Hanken H, Gröbe A, Assaf AT, Köhnke RH, Mehryar P, Riecke B, Wikner J.

J Craniomaxillofac Surg. 2015 Sep;43(7):1072-7. doi: 10.1016/j.jcms.2015.05.018. Epub 2015 Jun 4.

PMID:
26116310
10.
11.

Descriptive study of the longevity of dental implant surgery drills.

Allsobrook OF, Leichter J, Holborrow D, Swain M.

Clin Implant Dent Relat Res. 2011 Sep;13(3):244-54.

PMID:
22106473
12.

In Vitro Assessment with the Infrared Thermometer of Temperature Differences Generated During Implant Site Preparation: The Traditional Technique Versus the Single-Drill Technique.

Lucchiari N, Frigo AC, Stellini E, Coppe M, Berengo M, Bacci C.

Clin Implant Dent Relat Res. 2016 Feb;18(1):182-91. doi: 10.1111/cid.12246. Epub 2014 Jul 17.

PMID:
25040939
13.

Effects of bur wear during implant site preparation: an in vitro study.

Scarano A, Carinci F, Quaranta A, Di Iorio D, Assenza B, Piattelli A.

Int J Immunopathol Pharmacol. 2007 Jan-Mar;20(1 Suppl 1):23-6.

PMID:
17897497
14.

Temperature change in pig rib bone during implant site preparation by low-speed drilling.

Kim SJ, Yoo J, Kim YS, Shin SW.

J Appl Oral Sci. 2010 Sep-Oct;18(5):522-7.

15.

Osseointegration of two different phosphate ion-containing titanium oxide surfaces in rabbit cancellous bone.

Park JW.

Clin Oral Implants Res. 2013 Aug;24 Suppl A100:145-51. doi: 10.1111/j.1600-0501.2011.02406.x. Epub 2012 Jan 17.

PMID:
22251085
16.

Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills.

Scarano A, Piattelli A, Assenza B, Carinci F, Di Donato L, Romani GL, Merla A.

Clin Implant Dent Relat Res. 2011 Dec;13(4):319-23. doi: 10.1111/j.1708-8208.2009.00209.x. Epub 2009 Aug 3.

PMID:
19681941
17.
18.

Changes in implant stability using different site preparation techniques: twist drills versus piezosurgery. A single-blinded, randomized, controlled clinical trial.

Stacchi C, Vercellotti T, Torelli L, Furlan F, Di Lenarda R.

Clin Implant Dent Relat Res. 2013 Apr;15(2):188-97. doi: 10.1111/j.1708-8208.2011.00341.x. Epub 2011 Apr 19.

PMID:
21682844
19.

Atraumatic surgical technique and implant bed preparation.

Sutter F, Krekeler G, Schwammberger AE, Sutter FJ.

Quintessence Int. 1992 Dec;23(12):811-6.

PMID:
1305298
20.

The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability.

Ercoli C, Funkenbusch PD, Lee HJ, Moss ME, Graser GN.

Int J Oral Maxillofac Implants. 2004 May-Jun;19(3):335-49.

PMID:
15214217

Supplemental Content

Support Center