Warning: The NCBI web site requires JavaScript to function. more...
Fetching bibliography...
Generate a file for use with external citation management software.
Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs.
Vrancken SL, de Boode WP, Hopman JC, Singh SK, Liem KD, van Heijst AF.
Br J Anaesth. 2012 Mar;108(3):409-16. doi: 10.1093/bja/aer401. Epub 2011 Dec 14.
Similar articles
Detection and quantification of left-to-right shunting using transpulmonary ultrasound dilution (TPUD): a validation study in neonatal lambs.
Vrancken SL, van Heijst AF, Hopman JC, Liem KD, van der Hoeven JG, de Boode WP.
J Perinat Med. 2016 Oct 1;44(8):925-932. doi: 10.1515/jpm-2015-0310.
Influence of lung injury on cardiac output measurement using transpulmonary ultrasound dilution: a validation study in neonatal lambs.
Vrancken SL, de Boode WP, Hopman JC, Looijen-Salamon MG, Liem KD, van Heijst AF.
Br J Anaesth. 2012 Dec;109(6):870-8. doi: 10.1093/bja/aes297. Epub 2012 Aug 19.
Cardiac output measurement in ventilated lambs with a significant left-to-right shunt using the modified carbon dioxide fick method.
de Boode WP, Hopman JC, Wijnen MH, Tanke RB, van der Hoeven HG, Liem KD.
Neonatology. 2010;97(2):124-31. doi: 10.1159/000237223. Epub 2009 Sep 11.
Hemodynamic volumetry using transpulmonary ultrasound dilution (TPUD) technology in a neonatal animal model.
J Clin Monit Comput. 2015 Oct;29(5):643-52. doi: 10.1007/s10877-014-9647-6. Epub 2014 Dec 14.
Cardiac output can be measured with the transpulmonary thermodilution method in a paediatric animal model with a left-to-right shunt.
Nusmeier A, de Boode WP, Hopman JC, Schoof PH, van der Hoeven JG, Lemson J.
Br J Anaesth. 2011 Sep;107(3):336-43. doi: 10.1093/bja/aer127. Epub 2011 Jun 3.
Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.
Lindberg L, Johansson S, Perez-de-Sa V.
Pediatr Crit Care Med. 2014 Feb;15(2):139-47. doi: 10.1097/PCC.0000000000000053.
Reliability of lithium dilution cardiac output in anaesthetized sheep.
Axiak Flammer SM, Critchley LA, Weber A, Pirbodaghi T, Brinks H, Vandenberghe S.
Br J Anaesth. 2013 Nov;111(5):833-9. doi: 10.1093/bja/aet220. Epub 2013 Jul 9.
Feasibility and Accuracy of Cardiac Right-to-Left-Shunt Detection in Children by New Transpulmonary Ultrasound Dilution Method.
Boehne M, Baustert M, Paetzel V, Boethig D, Köditz H, Dennhardt N, Beerbaum P, Bertram H.
Pediatr Cardiol. 2017 Jan;38(1):135-148. doi: 10.1007/s00246-016-1494-4. Epub 2016 Nov 8.
Cardiac output measurement using an ultrasound dilution method: a validation study in ventilated piglets.
de Boode WP, van Heijst AF, Hopman JC, Tanke RB, van der Hoeven HG, Liem KD.
Pediatr Crit Care Med. 2010 Jan;11(1):103-8. doi: 10.1097/PCC.0b013e3181b064ea.
Transpulmonary thermodilution cardiac output measurement is not affected by severe pulmonary oedema: a newborn animal study.
Nusmeier A, Vrancken S, de Boode WP, van der Hoeven JG, Lemson J.
Br J Anaesth. 2013 Aug;111(2):286-92. doi: 10.1093/bja/aet021. Epub 2013 Feb 18.
Measurement of the ductal L-R shunt during extracorporeal membrane oxygenation in the lamb.
Tanke RB, van Heijst AF, Klaessens JH, Daniels O, Festen C.
J Pediatr Surg. 2004 Jan;39(1):43-7.
Quantification of left to right shunt in patent ductus arteriosus by color Doppler.
Harling S, Jansson T, Gudmundsson S, Pesonen E.
Ultrasound Med Biol. 2009 Mar;35(3):403-8. doi: 10.1016/j.ultrasmedbio.2008.09.017. Epub 2008 Dec 27.
Estimation of extravascular lung water using the transpulmonary ultrasound dilution (TPUD) method: a validation study in neonatal lambs.
Vrancken SL, Nusmeier A, Hopman JC, Liem KD, van der Hoeven JG, Lemson J, van Heijst AF, de Boode WP.
J Clin Monit Comput. 2016 Dec;30(6):985-994. Epub 2015 Nov 12.
[The effect of an intracardiac left-right shunt on thermodilution measurements of cardiac output. An extracorporeal circulation model].
Weyland A, Wietasch G, Hoeft A, Buhre W, Allgeier B, Weyland W, Kettler D.
Anaesthesist. 1995 Jan;44(1):13-23. German.
Validation of cardiac output measurement by ultrasound dilution technique with pulmonary artery thermodilution in a pediatric animal model.
Darling E, Thuramalla N, Searles B.
Pediatr Cardiol. 2011 Jun;32(5):585-9. doi: 10.1007/s00246-011-9915-x. Epub 2011 Feb 27.
Determination of cardiac output by ultrasound dilution technique in infants and children: a validation study against direct Fick principle.
Boehne M, Baustert M, Paetzel V, Köditz H, Schoof S, Happel CM, Bertram H.
Br J Anaesth. 2014 Mar;112(3):469-76. doi: 10.1093/bja/aet382. Epub 2013 Dec 13.
Continuous minimally invasive cardiac output monitoring with the COstatus in a neonatal swine model: recalibration is necessary during vasoconstriction and vasodilation.
Cisternas AF, Martin-Flores M, Gleed RD.
Paediatr Anaesth. 2015 Aug;25(8):852-859. doi: 10.1111/pan.12679. Epub 2015 May 9.
Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study.
Saxena R, Durward A, Puppala NK, Murdoch IA, Tibby SM.
Br J Anaesth. 2013 Mar;110(3):425-31. doi: 10.1093/bja/aes420. Epub 2012 Nov 25.
Novel continuous capnodynamic method for cardiac output assessment during mechanical ventilation.
Hällsjö Sander C, Hallbäck M, Wallin M, Emtell P, Oldner A, Björne H.
Br J Anaesth. 2014 May;112(5):824-31. doi: 10.1093/bja/aet486. Epub 2014 Feb 18.
Filters: Manage Filters