Items: 1 to 20 of 74

1.

Nontraumatic, spontaneous dislocation of polyethylene tibial insert 1 year after TKA.

Wright RC, Crouch A, Yacoubian SV, Raven RB 3rd, Falkinstein Y, Yacoubian SV.

Orthopedics. 2011 Dec 6;34(12):e933-5. doi: 10.3928/01477447-20111021-25. Erratum in: Orthopedics. 2012 Feb;35(2):130. Ravan, Raymond B 3rd [corrected to Raven, Raymond B 3rd].

PMID:
22146212
2.

Dissociation of polyethylene insert from the tibial baseplate following revision total knee arthroplasty.

Chen CE, Juhn RJ, Ko JY.

J Arthroplasty. 2011 Feb;26(2):339.e11-3. doi: 10.1016/j.arth.2010.04.016. Epub 2010 May 31.

PMID:
20570104
3.

Recurrent dissociation of the tibial insert after mini-subvastus posterior-stabilized total knee arthroplasty: a case report.

In Y, Sur YJ, Won HY, Moon YS.

Knee. 2011 Dec;18(6):461-3. doi: 10.1016/j.knee.2010.08.005. Epub 2010 Sep 15.

PMID:
20833051
4.

Spontaneous dislocation of a mobile-bearing polyethylene insert after posterior-stabilized rotating platform total knee arthroplasty: a case report.

Kobayashi H, Akamatsu Y, Taki N, Ota H, Mitsugi N, Saito T.

Knee. 2011 Dec;18(6):496-8. doi: 10.1016/j.knee.2010.10.007. Epub 2010 Nov 5.

PMID:
21115353
5.

Early nontraumatic fracture of the polyethylene tibial post in a NexGen LPS-Flex posterior stabilized knee prosthesis.

Lee CS, Chen WM, Kou HC, Lo WH, Chen CL.

J Arthroplasty. 2009 Dec;24(8):1292.e5-9. doi: 10.1016/j.arth.2009.02.013. Epub 2009 Mar 20.

PMID:
19303252
6.

Double-concave deformity of the polyethylene tibial post in posterior stabilized total knee arthroplasty.

Niki Y, Matsumoto H, Yoshimine F, Toyama Y, Suda Y, Banks SA.

J Arthroplasty. 2010 Apr;25(3):497.e7-10. doi: 10.1016/j.arth.2009.02.012. Epub 2009 Mar 4.

PMID:
19261434
7.

Failure of tibial polyethylene insert locking mechanism in posterior stabilized arthroplasty.

Thienpont E.

Knee Surg Sports Traumatol Arthrosc. 2013 Dec;21(12):2685-8. doi: 10.1007/s00167-012-2018-2. Epub 2012 May 1.

PMID:
22547247
8.

Spontaneous late dislocation of the high flexion tibial insert after Genesis II total knee arthroplasty. A case report.

Rutten SG, Janssen RP.

Knee. 2009 Oct;16(5):409-11. doi: 10.1016/j.knee.2009.01.009. Epub 2009 Mar 4.

PMID:
19264493
9.

Isolated tibial polyethylene insert exchange outcomes after total knee arthroplasty.

Willson SE, Munro ML, Sandwell JC, Ezzet KA, Colwell CW Jr.

Clin Orthop Relat Res. 2010 Jan;468(1):96-101. doi: 10.1007/s11999-009-1023-3. Epub 2009 Aug 12.

10.

Metal hypersensitivity in total knee arthroplasty: revision surgery using a ceramic femoral component - a case report.

Bergschmidt P, Bader R, Mittelmeier W.

Knee. 2012 Mar;19(2):144-7. doi: 10.1016/j.knee.2011.01.001. Epub 2011 Feb 2.

PMID:
21292491
11.

[Restricted motion after total knee arthroplasty].

Kucera T, Urban K, Karpas K, Sponer P.

Acta Chir Orthop Traumatol Cech. 2007 Oct;74(5):326-31. Czech.

PMID:
18001629
12.

Polyethylene subluxation: a radiographic sign of locking mechanism failure after modular total knee arthroplasty.

Hepinstall MS, Rodriguez JA.

J Arthroplasty. 2011 Jan;26(1):98-102. doi: 10.1016/j.arth.2009.10.020. Epub 2010 Feb 4.

PMID:
20137887
13.

Dislocation of the polyethylene inlay due to anterior tibial slope in revision total knee arthroplasty.

Waelchli B, Romero J.

Knee Surg Sports Traumatol Arthrosc. 2001 Sep;9(5):296-8.

PMID:
11685361
14.

Can high-flexion tibial inserts improve range of motion after posterior cruciate-retaining total knee arthroplasty?

Crow BD, McCauley JC, Ezzet KA.

Orthopedics. 2010 Sep 7;33(9):667. doi: 10.3928/01477447-20100722-03.

PMID:
20839712
15.

Five cases of failure of the tibial polyethylene insert locking mechanism in one design of constrained knee arthroplasty.

Rapuri VR, Clarke HD, Spangehl MJ, Beauchamp CP.

J Arthroplasty. 2011 Sep;26(6):976.e21-4. doi: 10.1016/j.arth.2010.07.013. Epub 2010 Aug 30.

PMID:
20801615
16.

Total knee arthroplasty for severe haemophilic arthropathy: long-term experience in Taiwan.

Chiang CC, Chen PQ, Shen MC, Tsai W.

Haemophilia. 2008 Jul;14(4):828-34. doi: 10.1111/j.1365-2516.2008.01693.x. Epub 2008 May 22.

PMID:
18510565
17.

Secondary knee instability caused by fracture of the stabilizing insert in a dual-articular total knee.

Boesen MP, Jensen TT, Husted H.

J Arthroplasty. 2004 Oct;19(7):941-3.

PMID:
15483815
18.

Early instability with mobile-bearing total knee arthroplasty: a series of 25 cases.

Ridgeway S, Moskal JT.

J Arthroplasty. 2004 Sep;19(6):686-93.

PMID:
15343526
19.

Outcome of isolated tibial polyethylene insert exchange after uncemented total knee arthroplasty: 27 patients followed for 8-71 months.

Jensen CL, Petersen MM, Jensen KE, Therbo M, Schrøder HM.

Acta Orthop. 2006 Dec;77(6):917-20.

PMID:
17260201
20.

Patella baja and total knee arthroplasty (TKA): etiology, diagnosis, and management.

Chonko DJ, Lombardi AV Jr, Berend KR.

Surg Technol Int. 2004;12:231-8.

PMID:
15455331

Supplemental Content