Format
Sort by

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 164

1.

Improved bacteria detection by coupling magneto-immunocapture and amperometry at flow-channel microband electrodes.

Laczka O, Maesa JM, Godino N, del Campo J, Fougt-Hansen M, Kutter JP, Snakenborg D, Muñoz-Pascual FX, Baldrich E.

Biosens Bioelectron. 2011 Apr 15;26(8):3633-40. doi: 10.1016/j.bios.2011.02.019.

PMID:
21392960
2.

Disposable amperometric magneto-immunosensor for direct detection of tetracyclines antibiotics residues in milk.

Conzuelo F, Gamella M, Campuzano S, Reviejo AJ, Pingarrón JM.

Anal Chim Acta. 2012 Aug 6;737:29-36. doi: 10.1016/j.aca.2012.05.051.

PMID:
22769033
3.
4.

Disposable amperometric immunosensing strips fabricated by Au nanoparticles-modified screen-printed carbon electrodes for the detection of foodborne pathogen Escherichia coli O157:H7.

Lin YH, Chen SH, Chuang YC, Lu YC, Shen TY, Chang CA, Lin CS.

Biosens Bioelectron. 2008 Jul 15;23(12):1832-7. doi: 10.1016/j.bios.2008.02.030.

PMID:
18424027
5.

Multifunctional magnetic bead-based electrochemical immunoassay for the detection of aflatoxin B1 in food.

Tang D, Zhong Z, Niessner R, Knopp D.

Analyst. 2009 Aug;134(8):1554-60. doi: 10.1039/b902401h.

PMID:
20448920
6.

Microfluidic immunosensor with gold nanoparticle platform for the determination of immunoglobulin G anti-Echinococcus granulosus antibodies.

Pereira SV, Bertolino FA, Messina GA, Raba J.

Anal Biochem. 2011 Feb 1;409(1):98-104. doi: 10.1016/j.ab.2010.10.015.

PMID:
20951112
7.

GoldMag nanocomposite-functionalized graphene sensing platform for one-step electrochemical immunoassay of alpha-fetoprotein.

Zhang B, Tang D, Liu B, Chen H, Cui Y, Chen G.

Biosens Bioelectron. 2011 Oct 15;28(1):174-80. doi: 10.1016/j.bios.2011.07.016.

PMID:
21803566
8.

Magneto immunoseparation of pathogenic bacteria and electrochemical magneto genosensing of the double-tagged amplicon.

Liébana S, Lermo A, Campoy S, Barbé J, Alegret S, Pividori MI.

Anal Chem. 2009 Jul 15;81(14):5812-20. doi: 10.1021/ac9007539.

PMID:
19537709
9.

Detection of pathogenic bacteria in food samples using highly-dispersed carbon particles.

Chemburu S, Wilkins E, Abdel-Hamid I.

Biosens Bioelectron. 2005 Sep 15;21(3):491-9.

PMID:
16076439
10.

Rapid electrochemical detection and identification of catalase positive micro-organisms.

Sippy N, Luxton R, Lewis RJ, Cowell DC.

Biosens Bioelectron. 2003 May;18(5-6):741-9.

PMID:
12706587
11.

Electrochemical magnetoimmunosensing platform for determination of the milk allergen β-lactoglobulin.

Ruiz-Valdepeñas Montiel V, Campuzano S, Conzuelo F, Torrente-Rodríguez RM, Gamella M, Reviejo AJ, Pingarrón JM.

Talanta. 2015 Jan;131:156-62. doi: 10.1016/j.talanta.2014.07.076.

PMID:
25281087
12.

Towards the development of a single-step immunosensor based on an electrochemical screen-printed electrode strip coupled with immunomagnetic beads.

Volpe G, Sozzo U, Piermarini S, Delibato E, Palleschi G, Moscone D.

Anal Bioanal Chem. 2013 Jan;405(2-3):655-63. doi: 10.1007/s00216-012-6141-1.

PMID:
22736227
13.

Electrochemical microfluidic biosensor for the detection of nucleic acid sequences.

Goral VN, Zaytseva NV, Baeumner AJ.

Lab Chip. 2006 Mar;6(3):414-21.

PMID:
16511625
14.
15.

Ferrocenemonocarboxylic-HRP@Pt nanoparticles labeled RCA for multiple amplification of electro-immunosensing.

Su H, Yuan R, Chai Y, Mao L, Zhuo Y.

Biosens Bioelectron. 2011 Jul 15;26(11):4601-4. doi: 10.1016/j.bios.2011.04.043.

PMID:
21621402
16.

A rapid method for detection of catalase-positive and catalase-negative bacteria based on monitoring of hydrogen peroxide evolution at a composite peroxidase biosensor.

Serra B, Zhang J, Morales MD, Guzmán-Vázquez de Prada A, Reviejo AJ, Pingarrón JM.

Talanta. 2008 May 30;75(4):1134-9. doi: 10.1016/j.talanta.2008.01.009.

PMID:
18585194
17.

Enzyme shadowing: using antibody-enzyme dually-labeled magnetic particles for fast bacterial detection.

Baldrich E, Muñoz FX.

Analyst. 2008 Aug;133(8):1009-12. doi: 10.1039/b805536j.

PMID:
18645641
18.

Detection of Escherichia coli and Salmonella typhimurium using interdigitated microelectrode capacitive immunosensors: the importance of transducer geometry.

Laczka O, Baldrich E, Muñoz FX, del Campo FJ.

Anal Chem. 2008 Oct 1;80(19):7239-47. doi: 10.1021/ac800643k.

PMID:
18771278
19.

Microfluidic-based electrochemical genosensor coupled to magnetic beads for hybridization detection.

Berti F, Laschi S, Palchetti I, Rossier JS, Reymond F, Mascini M, Marrazza G.

Talanta. 2009 Jan 15;77(3):971-8. doi: 10.1016/j.talanta.2008.07.064.

PMID:
19064077
20.

Highly sensitive amperometric immunosensor for the detection of Escherichia coli.

Abu-Rabeah K, Ashkenazi A, Atias D, Amir L, Marks RS.

Biosens Bioelectron. 2009 Aug 15;24(12):3461-6. doi: 10.1016/j.bios.2009.04.042.

PMID:
19501501
Items per page

Supplemental Content

Support Center