Format
Sort by
Items per page

Send to

Choose Destination

Links from PubMed

Items: 1 to 20 of 132

1.

Material properties of the cornea and sclera: a modelling approach to test experimental analysis.

Asejczyk-Widlicka M, Śródka W, Schachar RA, Pierścionek BK.

J Biomech. 2011 Feb 3;44(3):543-6. doi: 10.1016/j.jbiomech.2010.09.032. Epub 2010 Oct 25.

PMID:
20980007
2.

The elasticity and rigidity of the outer coats of the eye.

Asejczyk-Widlicka M, Pierscionek BK.

Br J Ophthalmol. 2008 Oct;92(10):1415-8. doi: 10.1136/bjo.2008.140178.

PMID:
18815423
3.

Study on establishment and mechanics application of finite element model of bovine eye.

Cui YH, Huang JF, Cheng SY, Wei W, Shang L, Li N, Xiong K.

BMC Ophthalmol. 2015 Aug 13;15:101. doi: 10.1186/s12886-015-0073-4.

4.

The effect of changing intraocular pressure on the corneal and scleral curvatures in the fresh porcine eye.

Pierscionek BK, Asejczyk-Widlicka M, Schachar RA.

Br J Ophthalmol. 2007 Jun;91(6):801-3. Epub 2006 Dec 6.

5.

Effect of material properties of the eyeball coat on optical image stability.

Sródka W, Pierscionek BK.

J Biomed Opt. 2008 Sep-Oct;13(5):054013. doi: 10.1117/1.2975844.

PMID:
19021393
6.

Effect of cornea material stiffness on measured intraocular pressure.

Kwon TH, Ghaboussi J, Pecknold DA, Hashash YM.

J Biomech. 2008;41(8):1707-13. doi: 10.1016/j.jbiomech.2008.03.004. Epub 2008 May 1.

PMID:
18455173
7.

Modelling the elastic properties of the anterior eye and their contribution to maintenance of image quality: the role of the limbus.

Asejczyk-Widlicka M, Sródka DW, Kasprzak H, Pierscionek BK.

Eye (Lond). 2007 Aug;21(8):1087-94. Epub 2006 Jun 23.

PMID:
16823462
8.

Optically inspired biomechanical model of the human eyeball.

Sródka W, Iskander DR.

J Biomed Opt. 2008 Jul-Aug;13(4):044034. doi: 10.1117/1.2952189.

PMID:
19021361
9.

Keratoconus prediction using a finite element model of the cornea with local biomechanical properties.

Carvalho LA, Prado M, Cunha RH, Costa Neto A, Paranhos A Jr, Schor P, Chamon W.

Arq Bras Oftalmol. 2009 Mar-Apr;72(2):139-45.

10.

Factors influencing optic nerve head biomechanics.

Sigal IA, Flanagan JG, Ethier CR.

Invest Ophthalmol Vis Sci. 2005 Nov;46(11):4189-99.

PMID:
16249498
11.

Computer simulation of arcuate keratotomy for astigmatism.

Hanna KD, Jouve FE, Waring GO 3rd, Ciarlet PG.

Refract Corneal Surg. 1992 Mar-Apr;8(2):152-63.

PMID:
1591211
12.

Nonlinear material properties of intact cornea and sclera.

Woo SL, Kobayashi AS, Schlegel WA, Lawrence C.

Exp Eye Res. 1972 Jul;14(1):29-39. No abstract available.

PMID:
5039845
13.

Computational simulation of altitude change-induced intraocular pressure alteration in patients with intravitreal gas bubbles.

Amini R, Barocas VH, Kavehpour HP, Hubschman JP.

Retina. 2011 Sep;31(8):1656-63. doi: 10.1097/IAE.0b013e318217ffa5.

PMID:
21765373
14.

Simulation model of an eyeball based on finite element analysis on a supercomputer.

Uchio E, Ohno S, Kudoh J, Aoki K, Kisielewicz LT.

Br J Ophthalmol. 1999 Oct;83(10):1106-11.

15.

A mechanical model for radial keratotomy: toward a predictive capability.

Wray WO, Best ED, Cheng LY.

J Biomech Eng. 1994 Feb;116(1):56-61.

PMID:
8189715
16.

Anterior chamber angle opening during corneoscleral indentation: the mechanism of whole eye globe deformation and the importance of the limbus.

Amini R, Barocas VH.

Invest Ophthalmol Vis Sci. 2009 Nov;50(11):5288-94. doi: 10.1167/iovs.08-2890. Epub 2009 Jun 24. Erratum in: Invest Ophthalmol Vis Sci. 2013 Nov;54(12):7323.

PMID:
19553625
17.

Importance of multiple loading scenarios for the identification of material coefficients of the human cornea.

Studer H, Riedwyl H, Büchler P.

Comput Methods Biomech Biomed Engin. 2012;15(1):93-9. doi: 10.1080/10255842.2011.552184. Epub 2011 Jul 13.

PMID:
21749272
18.

Numerical modelling of corneal biomechanical behaviour.

Elsheikh A, Wang D.

Comput Methods Biomech Biomed Engin. 2007 Apr;10(2):85-95. doi: 10.1080/10255840600976013.

PMID:
18651274
19.

A computational remodeling approach to predict the physiological architecture of the collagen fibril network in corneo-scleral shells.

Grytz R, Meschke G.

Biomech Model Mechanobiol. 2010 Apr;9(2):225-35. doi: 10.1007/s10237-009-0173-2. Epub 2009 Oct 4.

PMID:
19802726
20.

Optical coherence tomography measurements of the fresh porcine eye and response of the outer coats of the eye to volume increase.

Asejczyk-Widlicka M, Schachar RA, Pierscionek BK.

J Biomed Opt. 2008 Mar-Apr;13(2):024002. doi: 10.1117/1.2907453.

PMID:
18465965

Supplemental Content

Support Center